Oase 6600, 8000 Operating Instructions Manual

Page 1
Waterfall Pump 6600 / 8000
Operating instructions Notice d’emploi Instrucciones de uso
Page 2
2
- English -
CALL 1-866-627-3435
BEFORE RETURNING TO STORE.
Part
Description
QTY
A Pump 1
B 1½ in. and 2 in. ID tubing adapter 2
C Gasket 2
Information about these operating instructions
Welcome to OASE Living Water. You made a great choice with the purchase of this product Waterfall Pump 6600 /
8000. Prior to operating the unit, please read the instructions of use carefully and fully familiarize yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the enclosed instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please also hand over the instructions when passing the unit on to a new owner.
B.
A.
C.
Page 3
- English -
3
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
WARNINGS AND CAUTIONS SYMBOLS
Symbols used in these instructions
The symbols used in this operating manual have the following meanings: Risk of injury to persons due to dangerous electrical voltage.
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Risk of personal injury caused by a general source of danger.
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Important! The unit’s magnetic eld may affect the function of pacemakers.
Important information for trouble-free operation.
!
Intended use
Waterfall Pump 6600 / 8000, referred to in the following as “unit”, may only be used as specied in the following:
• For pumping normal pond water for lters, waterfalls and water courses.
• Operation under observance of the technical data. The following restrictions apply to the unit:
• Do not use in swimming pools.
• CAUTION - this pump has been evaluated for use with water only.
• Never run the unit without water.
• Do not use for commercial or industrial purposes.
• Do not use in conjunction with chemicals, food products, easily ammable or explosive substances.
• Do not connect to the domestic water supply.
• Do not exceed the voltage shown on the pump.
• Do not remove the grounding pin from the power cord plug.
• Inspect the power cord for damage before installation and maintenance.
Use other than that intended
This unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance
with these instructions or modication(s) to the unit will void the limited warranty.
!
Page 4
4
- English -
Installation
WARNING
Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
2. Attach the adapter to the pump rst, then connect tubing
to the adapter. NOTE: Tubing is NOT INCLUDED.
3. Attach the other end of the tubing to desired water
feature or spillway.
Submerged installation
1. For maximum water ow, it is recommended that the
largest tubing size for your pump is used.
If needed, cut the adapter as shown using a hacksaw;
consult packaging for tubing size.
2.
1.
Important:
The unit can be placed within the pond (submerged) or outside of the pond (dry)
It is recommened to place the unit horizontally on the ground ensuring its stable position.
Do not lift the pump by its power cord. Use the handle to lift and maneuver the pump.
Tubing
Adapter
Pump
Page 5
- English -
5
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
1.
Start-up
Attention! The pump must never run dry. Possible consequences: The pump will be destroyed. Protective measures: Check the water level at regular intervals. Always place the unit below water level.
Attention! The installed temperature sensor automatically turns the pump off, if it is overloaded. The pump automatically switches on again once the motor has cooled down. Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).
!
Important:
The unit switches on automatically when power connection is established.
1. Switching on: Connect power plug to the socket.
2. Switching off: Disconnect the power plug.
!
2. Mount pump to desired area using the holes on the bottom of the pump base.
Dry installation
1. Remove screen from pump.
1.
3. Attach both adapters to the pump rst using the
gasket then connect tubing to the adapters.
If needed, cut the adapter using a hacksaw;
consult packaging for tubing size.
NOTE: Tubing is NOT INCLUDED.
To prevent air from being taken in, ensure that unit and supply hose are always below the water level.
Tubing
Adapter
Pump
Adapter
3.
Installation (cont.)
2.
Tubing
Gasket
Gasket
Page 6
6
- English -
Maintenance and cleaning
Attention! Dangerous electrical voltage. Possible consequences: Death or serious injuries. Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Cleaning the unit
Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or when a drop in performance is detected. Clean the unit with warm water using a soft brush.
Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the function.
In the event of stubborn furring (calcium deposits), a common
household cleaner free from vinegar and chlorine can be used. Subsequently, clean the pump thoroughly using warm water.
Cleaning the pump
1. Disconnect the pump from the power source
○ Disconnect the tubing.
2. Remove the screen and disassemble the impeller
housing by unscrewing the screws to expose the
impeller assembly.
3. Remove the impeller assembly by pulling on the back round plate behind the impeller
4. Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing.
Check parts for damages such as cracked shaft, cracks in the bearing, and broken plastics. Replace parts if necessary.
5. Reassemble in the reverse order.
2.
3.
4.
Page 7
- English -
7
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Storage/Winterization
● Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are to be expected.
● Thoroughly clean the unit, check for damage.
● Ensure that the storage place is inaccessible to children.
Wear parts
The impeller unit is a wear part and is excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further information about the recycling of this product can be obtained from your local municipal authority.
Issue Cause Solution
The unit is not performing its suction function
Power supply not connected Connect pump power supply, check the supply lines to make sure
the voltage is correct
Impeller blocked, shaft broken Remove the inlet screen and/or pump cover, and impeller
housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also check to make sure that the ceramic shaft or bearings are not broken.
Pump is not completely submerged
Completely submerge the pump or make sure inline setup is completely below the water line.
Insufcient ow Pump is not completely
submerged
Completely submerge the pump or make sure inline setup is completely below the water line.
Screen clogged Clean
Tubing blocked Clean or replace tubing
Tubing kinked Eliminate kink, replace tubing if it is damaged
Excessive ow loss in the
tubing due to friction
Reduce tubing length to reduce frictional lossSelect larger hose diameter, adapt stepped hose adapter to
hose diameter.
Pump overload. The ow is
automatically stopped to protect the pump.
Clean the pump housing and impeller assembly ○ Reduce the ambient temperature (e.g. ensure that the specied
water temperature is adhered to, avoid direct sunlight)
Impeller worn Replace impeller
Unit switches off after a short running period
Excessive soiled water Clean impeller housing, bearing and impeller assembly
Impeller blocked, shaft broken Remove the inlet screen and/or pump cover, and impeller
housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also check to make sure that the ceramic shaft or bearings are not broken.
Water temperature too high Maximum water temperature: +95° F (+35 °C)
Troubleshooting
Page 8
8
Model
Model
No.
Rated
voltage
Power
consumption
Max. ow
rate
Max. head
height
Cord
length
Connection
for hoses
Dimensions Weight
6600 45425
120V /
60 Hz
460 W / 3.8 A 6,600 GPH 26.5 ft. 20 ft.
1 1/2”, 2”
11.9 x 6.8 x 8.6 in.
14.5 lbs.
8000 45426 650 W / 4.8 A 8,000 GPH 32 ft. 20 ft. 11.9 x 6.8 x 8.6 in.
Waterfall Pump
Pos.
Waterfall Pump
6600 8000
1 1-1/2 in. and 2 in. ID tubing adapter 1-1/2 in. and 2 in. ID tubing adapter
2 Screen Screen
3 Screw Screw
4 Impeller housing Impeller housing
5 Impeller Assembly Impeller Assembly
6 O-ring O-ring
7 Gasket Gasket
- English -
1
2
3
4
5
6
7
APPELEZ LE 1-866-627-3435
AVANT DE RETOURNER AU MAGASIN.
Page 9
OASE North America INC. · www.oase-livingwater.com
46631/09-16
Loading...