Operating instructions
Notice d’emploi
Instrucciones de uso
- English -
REMINDER
CALL 1-866-627-3435
BEFORE RETURNING TO STORE.
Part
APump1
3/4 in. ID tubing adapter with ow
B
control
Description
B.
A.
QTY
1
Information about these operating instructions
Welcome to OASE Living Water. You made a great choice with the purchase of this product Pond Pump 280 / 420 /
575. Prior to operating the unit, please read the instructions of use carefully and fully familiarize yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the
enclosed instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please
also hand over the instructions when passing the unit on to a new owner.
2
- English -
WARNINGS AND CAUTIONS SYMBOLS
Symbols used in these instructions
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage.
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are
not taken.
Risk of personal injury caused by a general source of danger.
!
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are
not taken.
Important! The unit is equipped with a permanent magnet. The magnetic eld may affect the function of pacemakers.
!
Important information for trouble-free operation.
Intended use
Pond Pump 280 / 420 / 575, referred to in the following as “unit”, may only be used as specied in the following:
• For circulating and pumping normal pond water for lters and additional water features.
• Operation under observance of the technical data.
The following restrictions apply to the unit:
• Do not use in swimming pools.
• CAUTION - this pump has been evaluated for use with water only.
• Never run the unit without water.
• Do not use for commercial or industrial purposes.
• Do not use in conjunction with chemicals, food products, easily ammable or explosive substances.
• Do not connect to the domestic water supply.
• Do not exceed the voltage shown on the pump.
• Do not remove the grounding pin from the power cord plug.
• Inspect the power cord for damage before installation and maintenance.
Use other than that intended
This unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance
with these instructions or modication(s) to the unit will void the limited warranty.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
3
- English -
Installation
WARNING
Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To
reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type
receptacle.
Important:
● Always place the unit below water level.
● It is recommened to place the unit horizontally on the ground ensuring its stable position.
● Do not lift the pump by its power cord.
1. Attach the adapter to the pump rst, then connect tubing
1.
to the adapter.
NOTE: Tubing is NOT INCLUDED.
2. Attach the other end of the tubing to desired water
feature or UV clarier.
Tubing
Adapter
Pump
Start-up
Attention! The pump must never run dry.
!
Possible consequences: The pump will be destroyed.
Protective measures: Check the water level at regular intervals. Always place the unit below water level.
Attention! The installed temperature sensor automatically turns the pump off, if it is overloaded. The pump
!
automatically switches on again once the motor has cooled down. Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).
Important:
● The unit switches on automatically when power connection
is established.
1. Switching on: Connect power plug to the socket.
1.
2. Adjust the ow control to the preferred setting.
3. Switching off: Disconnect the power plug.
2.
+
-
4
- English -
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
WARNING
!
This pump uses a very strong magnet to achieve superior performance. When removing the impeller assembly there
will be considerable magnetic force resisting the extraction of the impeller assembly. This is normal. Likewise when
replacing the impeller assembly there will be a strong magnetic force pulling the assembly into the pump to potentially
cause injury to ngers and in rare cases damaging the ceramic shaft or rear bearing. Use thick gloves when replacing
the impeller assembly.
Cleaning the unit
● Regular cleaning of the pump may be necessary depending
upon the environment in which it is operated. Clean the pump
when it is visibly soiled or when a drop in performance is
detected. Clean the unit with warm water using a soft brush.
● Never use aggressive cleaning agents or chemical solutions.
These could attack the housing surface or impair the function.
● In the event of stubborn furring (calcium deposits), a common
household cleaner free from vinegar and chlorine can be used.
Subsequently, clean the pump thoroughly using warm water.
Cleaning the pump
1.
1. Disconnect the pump from the power source.
○ Disconnect the tubing.
2. Remove the screen and disassemble the impeller
housing to expose the impeller assembly.
3. For Pond Pump 280 / 420, remove the impeller
assembly by gently pulling on the impeller blades.
For Pond Pump 575 remove the impeller assembly by
pulling on the back round plate behind the impeller.
2.
280 / 420575
3.
4. Use a soft cloth or brush to clean the impeller assembly
and the inside of the impeller housing.
● Check parts for damages such as cracked rotor, shaft or
bearing, cracks in the magnet, and broken plastics.
Replace parts if necessary.
5. Reassemble in the reverse order.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
4.
5
- English -
Storage/Winterization
● Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are
to be expected.
● Thoroughly clean the unit, check for damage.
● Ensure that the storage place is inaccessible to children.
Wear parts
The impeller unit is a wear part and is excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.
Troubleshooting
IssueCauseSolution
The unit is not
performing its
suction function
Insufcient owFlow control closed too farAdjust ow control
Unit switches
off after a short
running period
Power supply not connectedConnect pump power supply, check the supply lines to make sure
Impeller blocked, shaft brokenRemove the inlet screen and/or pump cover, and impeller
Pump is not completely
submerged
Screen cloggedClean
Tubing blockedClean or replace tubing
Tubing kinkedEliminate kink, replace tubing if it is damaged
Excessive ow loss in the
tubing due to friction
Pump is not completely submerged Completely submerge pump in the water
Pump overload. The ow is
automatically stopped to protect
the pump.
Impeller wornReplace impeller assembly
Excessive soiled waterClean impeller housing, bearing and impeller assembly
Impeller blocked, shaft brokenRemove the inlet screen and/or pump cover, and impeller
Water temperature too highMaximum water temperature: +95° F (+35 °C)
the voltage is correct
housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also check to make sure that
the ceramic shaft or bearings are not broken.
Completely submerge pump in the water
Reduce tubing length to reduce frictional loss
○ Clean the pump housing and impeller assembly
○ Reduce the ambient temperature (e.g. ensure that the specied
water temperature is adhered to, avoid direct sunlight)
housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also check to make sure that
the ceramic shaft or bearings are not broken.
6
- English -
Pond Pump
Rated
voltage
120V /
60 Hz
ModelModel No.
28045418
420454190.8 A / 42 W 420 GPH11.5 ft.
Pond Pump
575454201.2 A / 68 W575 GPH13.5 ft.5.82 x 4 x 6.5 in.
Pos.
1Pump screenPump screen
2Impeller housingImpeller housing
3Shaft supportShaft support
4ShaftShaft
5Impeller assemblyImpeller assembly
6O-ringO-ring
73/4 in. ID tubing adapter with ow control
280420
Power
consumption
0.45 A / 27 W280 GPH7.8 ft.
Max. ow rate
Max. head
height
cord
connection
length
for hoses
16 ft.3/4″
6
7
3
5
Dimensions
5.82 x 4 x 6.41 in.
4
23
1
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
7
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.