Instruction Manual
Temp-14
Single Input Thermistor
Thermometer
Part of Thermo Fisher Scientific
68X481902 Rev 0 10/0
TABLE OF CONTENTS
1. Quick Start Guide..................................... 1
2. Introduction .............................................. 2
3. Safety Precautions................................... 3
4. Specifications........................................... 4
5. Battery Installation And Replacement ..... 5
6. Inserting And Removing Optional Rubber
7. Assembling Optional Handsfree
8. Connecting A Thermistor......................... 8
9. Key Functions .......................................... 9
10. Display Overview ...................................10
11. Measurement Mode ............................... 11
12. Selecting Temperature Scale................. 12
13. Min And Max Function........................... 12
14. Auto Off Function................................... 13
15. Calibration.............................................. 13
16. Clear Field Calibration........................... 14
17. Field Calibration Unlock......................... 15
18.
19. Maintenance
20. Cleaning
21. Batteries
22. Trouble Shooting ...................................18
23. Accessories
24. Warranty
25. Product Return
26. Innocal® Calibration And Repair Services
Armour ..................................................... 6
Accesories
Field Calibration Lockout
(North America)...................................... 21
................................................ 7
........................ 16
........................................... 17
................................................. 17
................................................. 17
............................................ 19
................................................. 20
....................................... 20
1. QUICK START GUIDE
To ensure best results please read the
complete manual.
1. Connect probe.
2. Press the on/off key.
Press again to turn on backlight.
3. Select °C or °F display using °C/°F key.
4. Insert probe in sample.
Allow adequate time for reading to
stabilize.
Response time will vary depending on
probe.
5. Take reading.
Press hold key to freeze display.
Press min/max to display minimum or
maximum temperature.
6. Press and hold the on/off key for three
seconds to turn meter off.
- 1 -
2. INTRODUCTION
Thank you for choosing the
Temp-14 Thermistor
Thermometer. This sturdy
handheld thermometer
provides highly accurate
temperature measurements
using thermistor probes. The
Instrument is easy to use and
includes the following
features:
perator selection
• O
scale
•
Resolu
tion of 0.1° C/F
of
Celsius or Fahren
heit
• Large backlit LCD with two lines of four-digit
display
•
•
•
•
•
Hold
feature for
reading
Min and max readings display
calibration capab
Field
temporarily retaining a
ilit
y
Auto power off with Enable/Disable function
Low ba
ttery
warning
• Standard ¼ inch (6.3mm) phone jack
connector input
• Operates with a wide selection of probes
- 2 -
3. SAFETY PRECAUTIONS
Voltages present at the thermistors may
also be present at the battery terminals.
Always disconnect the thermistor when
changing batteries.
WARNIN
This instrument is designed to accept low
level signals supplied by standard 400
series thermistors. Under no
circumstances should the input voltage
exceed the specified 10 v rms.
1. Do not use or store this instrument in
microwave ovens or any abnormally hot or
cold areas.
2. Weak batteries should not be left in the
instrument. Dead batteries can leak and
cause damage to unit.
- 3 -
4. SPECIFICATIONS
Range
Resolution
Accuracy
Lcd Display
Out Of Range
Display
Display Update
Rate
Input
Input Protection
Battery
Battery Life
Auto Shutoff
Stability Criteria
Stated Accuracy
Useful Range
Storage
Humidity
Dimensions
(L x W x H)
Weight With
Batteries
Ingress Protection
Compliance
(For CE Mark)
–40 to 150 °C (–40.0 to 302.0 °F)
0.1 °C (0.1 °F)
±0.2 °C (±0.4 °F) in range -40 °C
to 125 °C (-40 °F to 257)
±0.5 °C (±0.9 °F) in range 125°C
to 150 °C (257to 302 °F)
4+4 digit, 58 X 40mm dual-line
display with backlight
“Ur” Or, “OPEN”
0.5 sec per update
One probe with ¼ inch (6.3mm)
phone jack connector
10 v rms
Three AA, 1.5V alkaline
700 hours continuous, typical
17 minutes after last key press
“STABLE” will display upon 5
seconds of stability
18°C to 28°C (64°F to 82°F)
0°C to 40°C (32°F to 104°F)
–40°C to 65°C (–40°F to 149°F)
10% to 90% (non-condensing)
Without Armor:
175mm X 97mm X 42mm
With Armor:
180mm X 102mm X 52mm
Without Armor: 267g
With Armor: 362g
Meets IEC-529 IP-54 for dust and
water-resistant enclosures
EN61326-1/A1: 1998
(EU EMC Directive)
- 4 -
5. BATTERY INSTALLATION AND
REPLACEMENT
Voltages present at the thermistors may
also be present at the battery terminals.
Always disconnect the thermistor when
changing batteries.
Weak batteries should not be left in the
instrument. Dead batteries can leak and
cause damage to unit.
The typical battery life is about 700 hours.
d se
ttings
are
Selecte
will remain in memory
turned
replac
off, or
ed.
while
stored in
even after
batteries
memory and
power is
are being
1. Before
2.
3.
4. Insert three
5.
changing
and disconnect probe
off
Loosen screw and
back
of case.
Remove
the t
hree
new
pol
arity.
Install
cover and
battery, tur
.
lift battery
AA batteries.
batteries
tighten
observing
screw
n instrume
cover
.
nt
off the
- 5 -
6. INSERTING AND REMOVING
OPTIONAL RUBBER ARMOUR
1. To insert thermometer into the optional
rubber armor, slide in from the top of meter
before pushing the bottom edges of meter
down to set it into position. Lift up the stand
at the back of meter for bench top
applications if necessary.
2. To remove thermometer from armor, push
out from the bottom edges of meter until it
is completely out of boot.
- 6 -