Network Video Technologies
(+1) 650.462.8100 • +44 (0) 208 977-6614
nvt.com • info@nvt.com
Page 2 of 5
RJ45 ETHERNET INTERFACE
Connectivity: RJ45, auto-crossover
Wire type: Cat5 or better
Distance: up to 328ft (100m)
Speed: 10/100 Base T, half/full duplex, auto-negotiation
auto MDI/MDIX cross-over
Latency: 3mS
Data throughput: 85Mbps ±10% useable bandwidth per network
Example: Four megapixel cameras, all sharing one
coax network, each sending 20Mbps video stream(s).
Power Output: This Power Sourcing Equipment (PSE) supports
Powered Devices (PDs) that are compatible with
IEEE 802.3af/at, or PDs that draw up to 50 watts*.
For maximum power/distance, 56 VDC appears
on all eight RJ45 pins, and are current-protected
and transient-protected.
2-WIRE BUILDING WIRING INTERFACEE
Connectivity: Screw terminals using the NV-BNCA adaptor
Impedance: 25 to 100Ω
Distance: See pages 5 & 6
Topology: Bus architecture supports star, daisy-chain, or any
combination. One control-room NV-EC1701U may support
multiple remote NV-EC1701Us.
Transmission technology: IEEE 1901, 128-bit AES encryption
*IMPORTANT NOTE:
Distance will often be shorter due to power supply capacity and wire
voltage-drop. See Maximum Per-Camera Wire Distance Chart on page 5.
WARNING: For safety, never use more than two power
supplies. Never exceed 120 watts.
LED STATUS INDICATORS
Power: Blue “Power On”
BNC/2-wire interface: Green “Link”
RJ45 Interface: Green “Link”
POWER CONSUMPTION
Consumption per transceiver: ≤ 3.0 W @ 10 to 56 VDC
Generated heat: 10 BTU/hour
Total system consumption: = total consumption of transceivers
+ total consumption of PDs (IP cameras)
+ total power dissipated in the wire
LED STATUS INDICATORS
MECHANICAL / ENVIRONMENTAL
Transceiver body dimensions: 5.1 in (131mm) long x
1.3 in (33mm) high x 1.5 in (38mm) wide
(excluding connectors and NV-BNCA adaptor)
Transceiver weight: 0.32lb. (145g)
Operating and storage temperature: 40°F to 185°F (-40°C to +85°C)
20 to 85% RH non-condensing
Transient Immunity: 5x20µS 3000A, 6000V
ESD 20KV, 200pF
POWER SUPPLY
Power supplies are external inline, with an IEC380-C14
power inlet and a 6 ft (1.18 m) line cord. Input voltage
is 100~240VAC 50/60Hz. A molded P1J 5.5mm barrel
connector provides a class 2 (SELV) regulated
output with one of these ratings:
Model NV-PS56-60W 56V 60W
4.90 in (125 mm) long x 2.00 in
(50 mm) wide x 1.25 in (32 mm) high
0.67 lb (0.30 Kg) shipping weight
Model NV-PS56-90W 56V 90W
5.77 in (147 mm) long x 2.86 in (60 mm) wide
x 1.27 in (32 mm) high
0.94 lb (0.43 Kg) shipping weight
Operating / storage temperature: -40°F to +185°F (-40°C to +85°C
20 to 5% relative humidity non-condensing)
Transient immunity: 5 x 20µS 3,000A, 6,000V ESD 20KV, 200pF
Use only the power cord provided with the unit or equivalent UL approved
type SPT-2, SVT, or SJT 18/3 AWG 100~240 VAC, 1 Amp 60°C max 15 ft
(4.5 m) long. One end with IEC380-C13 appliance coupler and the other end
with NEMA 1015P or equivalent for your country.
REGULATORY
UL Listed to IEC/UL 60950-1
Complies with FCC part 15A limits
WARRANTY Limited Lifetime
Specifications subject to change without notice.
+ 56VDC