NVT NV-EC-10-DEMO Installtion Instruction

0 (0)
NVT NV-EC-10-DEMO Installtion Instruction

QUICK INSTALL GUIDE - EC10

The plug and play EC10 switch is a ten port unmanaged Ethernet over Coax

 

 

EC10

switch. This powerful switch delivers fast ethernet and PoE+ over coax cable with

 

 

 

2,000 ft (609 m) reach. EC10 was designed to make the migration to IP quick, easy

 

 

 

and cost effective by leveraging an existing coax infrastructure. For complete

 

 

 

details refer to the Hardware Installation Guide at www.nvtphybridge.com.

 

 

 

NOTE: Please see page 3 for important safety instructions

 

 

 

 

 

 

 

 

EC10 SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front

 

 

 

 

Back

 

 

EC10 Switch Package Includes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

3

5

7

9

GbE 1

 

 

POWER

1 x EC10 Unit

 

 

 

 

 

 

 

 

 

GbE 2

RESET

 

 

1 x AC/DC Power Adapter

 

 

 

 

 

 

 

 

 

 

 

 

POWER

2

4

6

8

10

 

 

 

 

 

 

 

 

 

 

 

 

 

1 x Quick Install Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power LED

Downlink Ports 1-10

 

 

Uplink Ports 1-2

Reset Button

DC Jack

 

 

 

 

 

 

 

 

 

 

 

 

EC-Link

 

 

EC-Link Package

 

 

 

 

 

 

 

 

 

 

Network Infrastrusture

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BNC Port

 

 

 

 

(Sold Separately)Includes:

Ethernet Side

RJ45 Port

2 x EC-Links

Installation Details

Location Requirements:

Power – The AC/DC Power Adapter must be placed within 6 feet of an available power source.

Ventilation – To ensure proper ventilation of the EC10, leave at least 2 inches of unobstructed space on all sides of the unit. Downlink – The EC-Link adapters should be installed a minimum of 6 feet away from the EC10 switch.

Installation procedures will be trouble free if you ensure that the following items are available before you begin:

The CLEER switch model EC10, and all cables and accessories you received in the EC10 package

All EC-Link Adapters required for connecting the IP endpoint devices.

Standard CAT5e copper LAN cables for the uplink trunks (user supplied).

Coax cable for the downlink ports (user-supplied).

HARDWARE TOPOLOGY AND INSTALLATION OVERVIEW

1.Remove the EC10 switch and all accompanying accessories.

2.Remove all legacy cameras from the Coax cable.

Note: It is extremely important that non-IP, non-PoE cameras are not connected when you power on the EC10.

3.Connect an EC-Link to the Network jack on the IP endpoint and connect the BNC Jack on the EC-Link to one end of the Coax cable.

4.Connect the other end of the Coax cable to BNC connectors on the EC10 switch.

5.Connect the uplink cable from a Gigabit port to the IP PBX or network switch.

6.Power up the EC10.

7.For troubleshooting, please refer to the Hardware Installation Guide located at www.nvtphybridge.com.

8.To reset the unit, press the reset button.

EC10 Switch

100 Mbps PoLRE

Coax Cable

 

1

3

5

7

9

GbE 1

 

 

 

 

 

 

GbE 2

POWER

2

4

6

8

10

 

10 x 100 Mbps PoLRE BNC

2 x 1 Gbps Copper to LAN/SWITCH/NVR

100 Mbps PoLRE

Coax Cable

100 Mbps PoE

CAT5

100 Mbps PoE

CAT5

IP Endpoint

IP Endpoint

888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com

Copyright 2018 NVT Phybridge | 413-0006-B | Page 1

QUICK INSTALL GUIDE

NOTE THE FOLLOWING:

All of the above instructions provide basic installation information necessary for the proper and safe functioning of this equipment. Persons installing or maintaining this product must read all of the safety instructions and the parts of system grounding, which are applicable to the system being maintained. Only trained, qualified service personnel shall install or maintain this product.

WARNINGS

FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR RISK OF ELECTRICAL SHOCK.

ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.

Keep these instructions with the equipment.

Do not attempt to install or service this equipment unless you are skilled in the installation and maintenance of electronic telecommunications equipment and have successfully completed specific training for this equipment.

SAFETY WARNINGS AND PRECAUTIONS

Access to the interior of this unit shall be made only by a qualified technician.

To ensure adequate cooling of the equipment, a 2-inch unobstructed space must be provided around all sides of the unit.

To prevent the risk of shock or fire hazard, replace fuse with same type and rating.

Der Zugang ins Innere des Gerätes ist nur einem fachlich qualifizierten Techniker gestattet.

Um die Kühlung des Gerätes nicht zu beeinträchtigen, ist es notwendig, an allen Seiten des Gerätes ca 5 cm Raum zu lassen.

Zur Vermeidung der Stromschlag und Feuergefahr beim Auswechseln Sicherungen des gleichen Typs und der gleichen Nennleistung einsetzen.

Seul un spécialiste doit avoir accès l'appareil.

Afin de ne pas nuire au processus de refroidissement, il est nécessaire de laisser un espace d'environ 5 cm de chaque côté de l'appareil.

Afin d’éviter tout risque d’incendie ou d’électrocution, remplacez les fusibles par des fusibles de même type et ampérage.

El acceso al interior de esta unidad deberá ser realizado únicamente por un técnico cualificado.

Para asegurar un enfriamiento adecuado del equipo, se debe proporcionar un espacio sin obstrucciones de 2 pulgadas alrededor de todos los lados de la unidad.

Para evitar el riesgo de choque o peligro de incendio, reemplace el fusible con el mismo tipo y clasificación.

L'accesso all'interno di questa unità `deve essere effettuata solo da un tecnico qualificato.

Per garantire un adeguato raffreddamento dell'apparecchiatura, uno spazio libero da 2 pollici deve essere fornita intorno a tutti i lati dell'unità.

Per evitare che la prevenzione del rischio di scossa o di pericolo di incendio, sostituire il fusibile con lo stesso tipo e valore.

• .

• , 2- .

• , .

Juurdepääs interjööri selle üksuse tehakse ainult kvalifitseeritud tehnik.

Jahutuse tagamiseks seadme, 2-tolline vaba ruum peab olema ümber kõik küljed üksus.

Selleks, et vältida riski ning tulekahjuoht, vaheta kaitse sama tüüpi ja hinnang.

Η πρόσβαση στο εσωτερικό τη† μονάδα† πρέπει να γίνεται μόνο από εξειδικευμένο τεχνικό.

ια να εξασφαλιστεί η κατάλληλη ψύξη του εξοπλισμού, πρέπει να υπάρχει ένα† ελεύθερο† χώρο† 2 ιντσών γύρω από όλε† τι† πλευρέ† τη† μονάδα†.

ια να αποφύγετε τον κίνδυνο κρούση† ή πυρκαγιά†, αντικαταστήστε την ασφάλεια με τον ίδιο τύπο και την ίδια βαθμολογία.

Piekļuve interjera šīs vienības veic tikai kvalificēts tehniķis.

Lai nodrošinātu pietiekamu dzesēšanu iekārtu, 2 collu aizsegts telpu jānodrošina ap visām pusēm vienības.

Lai novērstu risku, ka trieciena vai ugunsgrēka briesmas, nomainīt drošinātāju ar tāda paša veida un reitingu.

Prieiga prie šio įrenginio viduje, turi būti atlikti tik kvalifikuotas specialistas.

Siekiant užtikrinti tinkamą aušinimą įranga, 2 colių užgriozdinti erdvę turi būti pateikta apie visus įrenginio pusių.

Siekiant užkirsti kelią šoko ar gaisro pavojus riziką, pakeiskite saugiklį su tos pačios rūšies ir įvertinimas.

A készülék belsejét csak szakképzett szakember végezheti.

A berendezés megfelelő hűtésének biztosítása érdekében egy 2 hüvelykes, akadálytalan helyet kell biztosítani a készülék minden oldalán.

Az ütésveszély vagy a tűzveszély elkerülése érdekében cserélje ki az azonos típusú és minősített biztosítékot.

Toegang tot het interieur van dit toestel wordt alleen door een gekwalificeerde technicus uitgevoerd.

Om een adequate afkoeling van de apparatuur te garanderen, moet een 2-inch vrijstaande ruimte rondom alle kanten van het apparaat worden aangebracht.

Om het risico op schokken of brandgevaar te voorkomen, vervang de zekering met hetzelfde type en de waarde.

Tilgang til det indre av denne enheten skal kun utføres av en kvalifisert tekniker.

For å sikre tilstrekkelig kjøling av utstyret, må det være 2 tommers uhindret plass rundt alle sider av enheten.

For å unngå fare for støt eller brannfare, bytt sikring med samme type og karakter.

888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com

Copyright 2018 NVT Phybridge | 413-0006-B | Page 2