IP MIGRATION MADE SIMPLE
MEDIA CONVERTER TO EXTENDER
The EC-Link and EC4 media converters support the IP end points leveraging the CLEER or
EC10 switches. In addition, the EC-Link can be easily converted to become an Ethernet
extender, with an EC-Link at the base unit and an additional media converter - either
another EC-Link or EC4 - at the other end.
If required, the media converters can be locally power ed to deliver a dditional power to the
IEEE compliant IP end point.
NVT
COAX MEDIA
CONVERTERS
DATA SHEET
Media Converters
At-a-Glance
The EC-Link and EC4 are energy-efficient media
converters for the CLEER and EC10 switches.
EC-Link and EC4 Connected to the EC10 Switch
COVER
EC-Link as an Ethernet Extender
Locally Powered or Connected To an “Always On” POE Injector
COVER
In addition, the EC-Link can be easily converted
to become an Ethernet extender.
Advantages
• Quick, easy and cost effective IP migration
• Energy efficient, consuming less than one
watt of power per EC-Link
• EC-Link can become an Ethernet extender
and paired with another media converter
(EC-Link or EC4) to create a single run
solution
OVER
YEARS
1994 ~ 2015
NVT
COAX MEDIA
CONVERTERS
DATA SHEET
EC4 Media Converter Technical Specifications
TECHNICAL FEATURES
Model NV-EC4
Dimensions
Weight 3.3 oz (96 g)
Mounting
Coax Interface 1 BNC port: COAX cable – RG59, RG6, RG11
• 0.98” x 2.75” x 4.3” (HxWxD)
• 2.5cm x 7cm x 11cm (HxWxD)
• Inline between the CAT5e/6 cable (to IP endpoints)
and the COAX cable (to CLEER/EC Switch)
• Inline between the CAT5e/6 cable (to IP endpoints)
and the COAX cable (to a second EC-Link when used
as an Extender)
Specifications subject to change without notice.
EC-Link Media Converter Technical Specifications
Model NV-LNK-02
Dimensions
Weight 1.48 oz (42 g)
Mounting
Coax Interface
• 0.83” x 1.23” x 3.46” (HxWxD)
• 2.1cm x 3.2cm x 8.8cm (HxWxD)
• Inline between the CAT5e/6 cable (to IP endpoint)
and the COAX cable (to CLEER/EC Switch)
• Inline between the CAT5e/6 cable (to IP endpoint)
and the COAX cable (to a second EC-Link when
used as an Extender)
1 BNC port: COAX cable – RG59, RG6, RG11
Specifications subject to change without notice.
Ethernet
Interface
Consumption
Power Injection
Operating
Temperature
Humidity 10% to 95% (non-condensing) at 95°F (35°C)
Ethernet
Interface
(Screw Terminal)
Consumption
Power Injection
Operating
Temperature
Humidity 10% to 95% (non-condensing) at 95°F (35°C)
4 x RJ45 port: 10/100 Base-T autosensing, IEEE
802.3af/at, 100 Mb connection to IP end device
Optional: 48VDC – 56VDC via an external AC/DC
DC IN
Power Adapter (IEC Class II isolated only)
Power
1W
DC voltage on RJ45 port (37-56V); Endpoint devices
(PoE)
must be compliant with IEEE 802.3af/at
32°F to 158°F (0°C to 70°C)
1 x RJ45 port: 10/100 Base-T autosensing, IEEE
802.3af/at, 100 Mb connection to IP end device
DC IN
Optional: 48VDC – 56VDC via an external AC/DC
Power Adapter (IEC Class II isolated only)
Power
0.9W
DC voltage on RJ45 port (37-56V); Endpoint devices
(PoE)
must be compliant with IEEE 802.3af/at
-58°F to 158°F (-50°C to 70°C)
Optional DC Power Adapters
Model NV-EC-48-PWR
Dimensions
Weight 17.99 oz (510 g)
Output 48VDC 1A
Operating
Temperature
Storage
Teperature
• 1.73” x 1.81” x 4.13” (WxHxD)
• 44mm x 30mm x 105mm (WxHxD)
Input 100-240VAC 50/60 Hz 100VA; IEC380-C14 power inlet
-20.2°F to 113°F (-29°C to 45°C)
-40°F to 167°C (-40°C to 75°C)
CANADA | UNITED STATES | UNITED KINGDOM | PRAGUE | MEXICO | COLOMBIA | SINGAPORE
www.nvt.com | +1.650.462.8100 | Toll Free: 1.800.959.9870 | UK +44 (0) 20 8977 6614 | info@nvt.com
Model NV-EC-100-PWR
Dimensions
Weight 17.99 oz (510 g)
Output 48VDC 2A
Operating
Temperature
Storage
Teperature
• 2.36” x 1.42” x 6.06” (WxHxD)
• 60mm x 36mm x 154mm (WxHxD)
Input 100-240VAC 50/60 Hz 150VA; IEC380-C14 power inlet
-20.2°F to 113°F (-29°C to 45°C)
-40°F to 167°C (-40°C to 75°C)