MULTI-SOURCE/ MULTI-ZONE AUDIO
DISTRIBUTION SYSTEM
OWNERS MANUAL
DANGER
EXPOSURE TO EXTREMELY HIGH NOISE LEVELS MAY CAUSE
A PERMANENT HEARING LOSS. INDIVIDUALS VARY
CONSIDERABLY TO NOISE-INDUCED HEARING LOSS, BUT
NEARLY EVERYONE WILL LOSE SOME HEARING IF EXPOSED
TO SUFFICIENTLY INTENSE NOISE FOR A SUFFICIENT TIME.
THE U.S. GOVERNMENT'S OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION (OSHA) HAS SPECIFIED THE
FOLLOWING PERMISSIBLE NOISE LEVEL EXPOSURES:
DURATION PER DAY IN
HOURS
8
6
4
3
2
1
SOUND LEVEL db FLOW
RESPONSE
90
93
95
97
100
103
ACCORDING TO OSHA, ANY EXPOSURE WITHIN THE ABOVE
PERMISSIBLE LIMITS COULD RESULT IN SOME HEARING LOSS.
EAR PLUGS OR PROTECTORS IN THE EAR CANAL OR OVER
THE EARS MUST BE WORN WHEN OPERATING THIS
AMPLIFICATION SYSTEM IN ORDER TO PREVENT A
PERMANENT HEARING LOSS. IF EXPOSURE IN EXCESS OF THE
LIMITS AS PUT FORTH ABOVE, TO INSURE AGAINST
POTENTIALLY HARMFUL EXPOSURE TO HIGH SOUND
PRESSURE LEVELS, IT IS RECOMMENDED THAT ALL PERSONS
EXPOSED TO EQUIPMENT CAPABLE OF INDUCING HIGH SOUND
PRESSURE LEVELS, SUCH AS THIS AMPLIFICATION SYSTEM,
BE PROTECTED BY HEARING PROTECTORS WHILE THIS UNIT
IS IN OPERATION.
THIS APPARATUS SHALL NOT BE
EXPOSED TO DRIPPING OR
SPLASHING. NO OBJECTS FILLED WITH
LIQUIDS (SUCH AS VASES) SHALL BE
PLACED ON THE APPARATUS.
IMPORTANT
1. Read all safety and operating instructions before using this product.
2. All safety and operating instructions should be kept for future reference.
3. Obey all cautions in the operating instructions and on the back of the
unit.
4. All operating instructions should be followed.
5. This product should not be used near water, i.e., bathtub, sink, swimming
pool, wet basement, etc.
6.This product should be located so that its position does not interfere
with proper ventilation. It should not be placed flat against a wall or
placed in a built-in enclosure that will impede the flow of cooling air.
7. This product should not be placed near a source of heat, such as a
stove, radiator, or another heat-producing amplifier.
8.Connect only to a power supply of the type indicated on the back of the
amplifier near the power supply cord.
9.Do not break off the ground pin of the power supply cord.
10. Power supply cords should always be handled carefully. Never walk on
or place equipment on power supply cords. Periodically check cords for
cuts or signs of stress, especially at the point where the cord exits the
unit.
11. The power supply cord should be unplugged when the unit is unused
for long periods of time.
12. If this product is to be mounted in an equipment rack, rear support
should be provided.
13. Metal parts and vinyl covering may be cleaned with a damp rag.
14. Care should be taken so that objects do not fall and liquids are not
spilled into the unit through the ventilation ports or any other openings.
15. This unit should be checked by a qualified service technician if:
A. The power supply cord or plug has been damaged.
B. Anything has fallen or been spilled into the unit.
C. The unit does not operate correctly.
D. The unit has been dropped or the enclosure damaged.
16. The user should not attempt to service this equipment. All service work
must be done by a qualified service technician for warranty repairs.
TO AVOID ELECTRICAL SHOCK, DO
NOT DISASSEMBLE. REFER SERVICING
TO QUALIFIED PERSONNEL ONLY!
CAUTION
RISK OF ELECTRIC
SHOCK
CAUTION:
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF UNINSULATED DANGEROUS VOLTAGE WITHIN
THE PRODUCTS ENCLOSURE THAT MAY BE OF SUFFICIENT
MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO
PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE
(SERVICING) INSTRUCTIONS IN THE LITERATURE
ACCOMPANYING THE UNIT.
TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE CHASSIS. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
THIS AMPLIFIER HAS BEEN DESIGNED AND CONSTRUCTED TO PROVIDE
ADEQUATE POWER RESERVE FOR PLAYING MODERN MUSIC THAT MAY
REQUIRE OCCASIONAL PEAK POWER. EXTENDED OPERATION AT
ABSOLUTE MAXIMUM POWER IS NOT RECOMMENDED BECAUSE THIS
COULD DAMAGE THE ASSOCIATED LOUDSPEAKER SYSTEM. PLEASE BE
AWARE THAT MAXIMUM POWER CAN BE OBTAINED. WITH VERY LOW
SETTINGS OF THE MASTER VOLUME CONTROLS IF THE INPUT SIGNAL
IS VERY STRONG.
INTRODUCTION
Congratulations on your purchase of the NUVO E Series audio distribution system. The E Series offers the newest
in multi-zone/multi-source audio technology in an attractive, easy-to-install, and simple-to-use package.
The E Series system is designed for the home owner. Its attractive, backlit keypads are elegant, easy-to-operate,
and able to be customized for any installation. Included with each keypad are molded, screwless cover plates in
white, ivory, almond and black, to best match your homes decor in every room. Also included with each keypad
are thirty preprinted, interchangeable buttons, which allow the system to be specifically tailored for each installation.
Using the E Series is as easy as the push of a button. The E6M amplifier is designed to be turned on and left on.
Each zone can then be turned on or off independently, or all zones can be turned off simultaneously by using the
ALL OFF command at any one of the keypads. Individual volume control and mute for each zone is also as easy
as the push of a button.
For the ultimate convenience, each E Series system includes an NV-RC1 infrared (IR)remote control. Complete
control of audio source selection, volume, mute, or the innovative ALL OFF function are in the palm of your hand.
Aim your RC1 remote at the IR receiver on the keypad, press the button for the command you desire, and the E
Series does the rest.
The built-in IR repeater allows for direct access to all of your audio source equipment by utilizing the individual
audio components hand-held remote, or you can enjoy the convenience of having all of the commands of your
audio source equipment in one universal learning remote. In addition, the RC1 remote is the perfect tool for teaching
all of the functions of the E Series keypads to any learning remote control, so you have complete control of not
only the E Series system, but of all your individual audio components from any room of the house.
The following pages of the manual are step-by-step instructions for installing the E Series in your home. We suggest
that you read and understand this installation guide in its entirety before installing your NUVO E Series system.
Proper installation will insure years of audio enjoyment.
NUVO Model NV-E6MS/NV-E6XS System Components
NV-E6MS: Main Audio Distribution System
Part #DescriptionQty
NV-E6MSix Source Distribution Amplifier1
NV-RC1IR Remote Control1
NV-EKPBacklit Keypad6
NV-EZPMulti-port Connection1
NV-VECMini Mouse IR Emitter with Feedback LED 4
NV-NC110 ft. Network Cable1
NV-E6XS: Expander Audio Distribution System
Part #DescriptionQty
The amplifier is designed to be turned on and remain
on. The power button supplies power to the system.
Each zone can then be turned on or off independently.
This blue LED (light-emitting diode) will remain lit as
long as the power button is engaged. Note that once
the system is installed, it is designed to be left on.
These LEDs indicate the power status of each zone.
Once in standby mode, each zone has the ability to be
powered up or down independently.
ODD NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER)
EVEN NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER)
123456
6
7
LEFT
- +
SUM
DIAGNOSTICCONTROL
RIGHT
REFER TO MANUAL
- +
0123
NETWORK
CONNECT TO
NV-EZP
8
UNIT ON
MUTE
+12V G
N.O. G
-INPUT- -OUTPUT-
DIGITAL OUTPUT
CONNECT TO
NV-E6X
9
MODEL NV-E6M
SIX SOURCE SIX ZONE
AUDIO DISTRIBUTION SYSTEM
120V 60Hz 300W
KUSTOM INC. CINCINNATI, OH USA
0215
10
The E Series amplifier accepts up to six audio sources. These can
accept any audio component capable of supplying a line level signal.
Preamp lineouts for each zone allow you to easily use an additional
amplifier to power additional speakers in a zone. Only use one pair
of 8-ohm speakers per zone.
Individual stereo speaker outputs provide 20 watts output per channel
to each zone.
4
Audiolink:
5
Routed IR Outputs:
6
Diagnostic LEDs:
7
RJ45 Input:
8
Datalink:
Mute Input:
9
10
AC:
This multi-pin connection is used to transfer the audio information from
the E Series main amplifier to the expander amplifier. This output is
used to expand the system to twelve zones.
These outputs transfer IR signals from the zones to your source
components. They are routed odd and even so that when source
1, 3, or 5 is selected at any of the keypads, the IR outputs 1, 3, and 5
all flash IR commands. Similarly, when source 2, 4, or 6 is
selected at any of the keypads, the IR outputs 2, 4, and 6 all flash.
The Sum output always flashes IR commands regardless of the
source selected.
These four LEDs indicate the operation of the systems MPU. They
also indicate correct communication through the system.
A single Cat-5 wire terminated with an RJ45 connector carries all the
information from the individual zones to the main amplifier.
This multi-pin connection transfers all the digital information from the
main amplifier to the expander amplifier. This output is used to expand
the system from six to twelve zones.
This input temporarily mutes the system when the pins are shorted by
a dry contact closure.
Detachable power cord connects the system to an external AC power
supply.
Page 3
E Series Keypad
1
2
3
4
CD1
CD2
SAT
TUN1
TUN2
TUN3
ALL OFF
ONOFF
MUTE
VOL
VOL
5
6
7
8
9
Cover Plate:
1
Source Selection:
2
Source Buttons:
3
RJ45 Connection:
4
5
ALL OFF Button:
Zone ON/OFF Button:
6
Mute Button:
7
Volume Button:
8
IR Receiver:
9
The E Series keypad comes with four molded, replaceable covers in
white, ivory, almond, and black.
The selected source button remains a backlit green until a new source
is selected or the zone is turned off. A flashing source button indicates
that the zone is muted.
Each keypad comes with 30 preprinted replaceable buttons, so the
system can be customized for the homeowner.
Each keypad plugs into a dedicated Cat-5 wire using an RJ45 phone
jack. The system operates on standard EIA/TIA 568A wiring.
This turns the entire system off from any of the zone keypads.
Each zone can be individually turned on or off.
Each zone can be individually muted. The source selection button
will flash indicating a muted zone.
The musics volume may be increased or decreased individually in
each zone.
Infrared commands can be used to control the E Series system as
well as individual source functions.
Page 4
Loading...
+ 13 hidden pages