Six-Source, Six-Zone Audio Distribution System
NV-E6GMS, NV-E6GXS
Installation Guide
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
Danger
Exposure to extremely high noise levels may cause a permanent
hearing loss. Individuals vary considerably to noise induced hearing
loss but nearly everyone will lose some hearing if exposed to sufficiently
intense noise for a sufficient time. The U.S. Government's
Occupational Safety and Health Administration (OSHA) has specified
the following permissible noise level exposures:
DURATION PER DAY (HOURS)86432 1
SOUND LEVEL (dB)90 93 95 97 100 103
According to OSHA, any exposure in the above permissible limits could
result in some hearing loss. Ear plugs or protectors in the ear canal or over
the ears must be worn when operating this amplification system in order to
prevent a permanent hearing loss. If exposure in excess of the limits as
put forth above, to insure against potentially harmful exposure to high
sound pressure levels, it is recommended that all persons exposed to
equipment capable of inducing high sound pressure levels, such as this
amplification system, be protected by hearing protectors while this unit is in
operation.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE
TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF IMPORTANT OPERATINGAND MAINTENANCE (SERVICING)
INSTRUCTIONS IN THE LITERATUREACCOMPANYING THE UNIT.
APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE CHASSIS. NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
1.Read all safety and operating instructions before using this
product.
2.All safety and operating instructions should be kept for future
reference.
3.Read and understand all warnings listed on the operating
instructions.
4 . Follow all operating instructions to operate this product.
5.This product should not be used near water, i.e. bathtub, sink,
swimming pool, wet basement, etc.
6.Only use dry cloth to clean this product.
7.Do not block any ventilation openings, It should not be placed flat
against a wall or placed in a built-in enclosure that will impede the
flow of cooling air.
8.Do not install this product near any heat sources ; such as,
radiators, heat registers, stove or other apparatus (including heat
producing amplifiers) that produce heat.
9.Do not defeat the safety purpose of the polarized or groundingtype plug. Apolarized plug has two blades with one wider than the
other.Agrounding-type plug has two blades and a third grounding
prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord being walked on or pinched, particularly at
plugs, convenience receptacles and the point where they exit
from the apparatus. Do not break the ground pin of the power
supply cord.
11 . Only use attachments specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by
the manufacturer or sold with the apparatus. When a cart is used,
use caution when moving cart/apparatus combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for
long periods of time.
14. Care should be taken so that objects do not fall and liquids are
not spilled into the unit through the ventilation ports or any other
openings.
15. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way;
such as, power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally
or has been dropped.
16. WARNING: To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
FRENCH
Danger
L‘exposition a des niveaux eleves de bruit peut provoquer une perte
permanente de l’audition, Chaque organisme humain reagit
differemment quant a la perte de l’audition, mais quasiment tout le
monde subit une diminution de I’acuite auditive lors d’une exposition
suffisamment longue au bruit intense. Les autorites competentes en
reglementation de bruit ont defini les expositions tolerees aux niveaux
de bruits:
DURE EN HEURES PAR JOUR864321
INIVEAU SONORE CONTINU EN dB90 93 95 97 100 103
Selon les autorites, toute exposition dans les limites citees ci-dessus,
peuvent provoquer certaines pertes d’audition. Des bouchons ou
protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors
de l’utilisation de ce systeme d’amplification afin de prevenir le risque
de perte permanente de l’audition, Dans le cas d’expositions
superieures aux limites precitees il est recommande, afin de se
premunir contre les expositions aux pressions acoustiquese I evees
potentielIement dangeure u ses, aux personnes exposees aux
equipements capables de delivrer de telles puissances, tels ce
systeme d’amplification en fonctionnement, de proteger l’appareil
auditif.
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
ATTENTION:AFIN DE LlMlTER LE RISQUE DE CHO ELECTR/QUE, NE
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT
QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR
PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES
DOCUMENTS FOURNIS AVEC CE PRODUIT.
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE
ELECTRIQUE, NE PAS EXPOSER CETAPPAREILA LA PLUIE OU A
L'HUMIDITE.
PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE
PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR.
CONFER LE SERVICE APRES-VENTEAUX
REPARATEURS
IMPORTANTES INSTRUCTIONS DE SECURITE
1. Lire avec attention toutes les recommandations et précautions
d'emploi avant d'utiliser ce produit.
2. Toutes les recommandations et précautions d'emploi doivent être
conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les avertissements énumérés dans les
précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par exemple
baignoires, éviers, piscine, sous-sol humides ... Etc.
6. Utiliser exclusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le
produit tout contre un mur ou dans une enceinte fern
gênerait le flux d'air nécessaire au refroidissement.
8. Ne pas placer le produit près de toute source de chaeur telle que
radiateurs, arrivées d'air chaud, fourneaux ou autres appareils
générant de la chaleur (incluant les amplificateurs producteurs
de chaleur) .
9. Ne pas négliger la sécurité que procure un branchement polarisé
ou avec raccordement à la terre, Un branchement polarisé
comprend deux fiches dont l'une est plus large que l'autre. Un
branchement à la terre comprend deux fiches plus une troisième
reliée à la terre. Si la fiche secteur fournie ne s'insert pas dans
votre prise de courant. consulter un 'électricien afin de remplacer
votre prise obsolète.
Protéger
10.le cordon d'alimentation de tout écrasement ou
pincement, particulièrement au niveau des fiches, des
réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas
casser la fiche de terre du cordon d'alimentation.
11. Utiliser uniquement les accessoires spécifiés par le constructeur.
12. Utiliser uniquement avec le chariot de transport, le support, le
trépied, la console ou la table spécifiés par le constructeur ou
vendus avec l'appareil. Lors de l'utilisation d'un chariot, bouger
avec précaution l'ensemble chariotlappareil afin d'éviter les
dommages d'un renversement.
13 Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé
pendant une longue période.
14. Des précautions doivent être prises afin qu'aucun objet ne tombe
et qu'aucun liquide ne se répande à l'intérieur de l'appareil par
les orifics de ventilation ou n'importe quelle autre ouverture.
15. Pour toutes interventions techniques s'adresser à un technicien
qualifié.L'intervention technique est nécessaire lorsque l'appareil
a été endommagé de n'importe quelle façon, comme par
exemple si le cordon secteur ou sa fiche sont détériorés,si du
liquide a coulé ou si des objets sont tombés à l'intérieur de
l'apparei1,si l'appareil a été exposé à la pluie ou à l'humidité, s'il
ne fonctionne pas normalement ou s'il est tombé.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc
electrique ne pas exposer l'appareil à la pluie ou à l'humidité.
ée, cela
Table of Contents
IntroductionPage 3
Back Panel Features
Control Pad FeaturesPage 5
RC1 Remote ControlPage 6
Installing the Essentia System in Your Home
I. Prewire CAT5 TerminationPage 7
II. Terminating the Speaker WirePage 8
III. Installing the Essentia AmplifierPage 8
IV. Installing the NV-E6GMAP AllPortPage 8
V. Connecting the Allport to the Essentia AmplifierPage 9
VI. Attaching Audio Source Equipment
Setting up the T2G Tuners, M3 Audio Server and NuVoDock for iPod
for use with NuVoNetPage 9
VII. Connecting the IR EmittersPage 10
NuVo T2G Tuner Direct Numeric AccessPage 10
VIII. Expanding Essentia to 16 ZonesPage 11
IX. Using the Essentia Configurator SoftwarePage 12
1. Main StartupPage 12
2. IR LibrariesPage 12
3. Defining Sources
4. MacrosPage 16
5. ZonesPage 18
6. System SettingsPage 21
7. Update SystemPage 22
X. Control Pad SetupPage 24
XI. Using the Control Pad’s MENU ButtonPage 24
FavoritesPage 24
SourcesPage 25
Advanced Zone ControlPage 25
SetupPage 26
Favorites #1-12Page 26
Zone SettingsPage 26
Source SettingsPage 28
System SettingsPage 28
XII. Essentia AccessoriesPage 30
The NV-I8DLS Learning Station InterfacePage 29
NV-MI1 Mute Interface AdaptorPage 32
NV-LSI24 Local Source InterruptPage 33
NV-LSA40 Local Source AmplifierPage 34
NV-LSA40PD Power Distribution HubPage 35
Congratulations on the purchase of NuVo's new Essentia System. Essentia provides 40 startlingly clear watts of sound to up to 12
listening zones(12 zones with the addition of the expander). NuVo's Generation D amplification uses the latest in digital
technology to provide peak performance in a system that sets a new standard for efficiency and energy conservation. Essentia is
the first distributed audio system of its type to bear ENERGY STAR®. This means it consumes less than 1 watt of power in standby
mode. Even with all the zones turned on and in full operation, the Essentia System's efficient design sets a new standard in low
power consumption.
Essentia truly offers the best in affordable distributed audio for the home. NuVo's state-of-the-art NuVoNet communication
through Essentia's award winning Control Pads allows you to interact with your source equipment as if you are standing at your
equipment rack. Essentia is a music entertainment system like no other multi-source, multi-zone audio system in its class.
3
Essentia Back Panel
1807
100~240V 50~60Hz 130W
MADEIN CHINA
12
56
1
Source Inputs:
1.The Essentia will accept up to six audio sources. These are connected to Essentia's main and expander amplifiers
FIXED VAR
ZONE
1
ZONE
2
2
TRIG
1
ALLPORT CONNECTION
3
4
IR OUTPUTS
23456
5
RS232
7
6
SUM
8
STATUS
NuVoNet
9
MUTE
LINK
10
NuVoTechnologiesLLC Hebron,Kentucky USA•
www.nuvotechnologies.com
STD.60065CERTIFIED
3033118
11
MODEL NV-E6GM
SIXSOURCE SIXZONE
AUDIODISTRIBUTION SYSTEM
RoHS
CONFORMSTO UL
TOCAN/CSA STD.
N1839
C22.2No.60065:03
with standard stereo RCA cables.
Fixed Lineouts:
2.These preamp lineouts are used for sending an audio signal to an external power amplifier. This is useful for
large areas that require additional pairs of speakers. These outputs are constant, so an amplifier connected to it will not
change volume with that zone's Control Pad. Zones 1 and 2 both have a fixed lineout.
Variable Lineouts:
3.These preamp lineouts are also used for sending an audio signal to an external power (needs left justified)
amplifier. Use the variable output when you want the volume of the additional amplifier to be controlled by the zone's Control
Pad. Like the Fixed Lineouts, zones 1 and 2 each have a variable lineout.
Zone Trigger Outputs:
4.These 5-volt outputs are zone - specific voltage triggers for external amplification.
Allport Connection:
5.This 25-pin connection consolidates the zone speaker connections to the back of the Allport hub into a
single cable connection on the back of the Essentia amplifier.
. IR emitter Outputs:
6IR signals received from the Control Pads are passed through the IR outputs to the source equipment using
the supplied IR emitters. Outputs 1-6 are routed to the corresponding sources, and the SUM output is common and will pass all
IR signals.
RS232:
7.The 9-pin RS232 connection is a bi-directional serial port that allows the Essentia System to be controlled by an
external home automation device. It is also used for configuration programming download.
Status:
8.This is a constant 5-volt output for triggering external equipment. There is no voltage output when the zones are off.
NuVoNet:
9.This RJ45 connection is the input for all zone information coming from the Essentia Control Pads and all
communication with the NuVoNet Suite source components. This connection is made using the supplied pre-terminated CAT5 or
any network CAT5 cable.
Link:
10.This RJ45 output is designed to connect to the Link input on the Essentia Expander component and transfers all zone
control commands from the Main Unit's NuVoNet or RS232 command input to the Expander for an additional six zones.
Mute:
11.This input is designed to temporarily mute any audio playing through the system when the doorbell or phone rings. This
works in conjunction with the NuVo NV-MI1 mute interface accessory. It also acts as a trigger for whole house paging through
any third party paging device when set for this function in the Configurator Software.
AC:
12.A detachable power cord connects the system to an external AC power supply.
4
Essentia Control Pad
1
2
3
M3A
2 OF 2-Follow th...
drift-Edge of Tom
1:19
3:48
12
4
11
5
10
6
7
9
8
Source Indicator:
1.This indicates the current audio source playing in that zone. Source names can be customized in the
Configurator Software with a three-character designation.
Wall Plate:
2.Each Control Pad comes with white, ivory, almond, and black trim plates that offer a screwless and elegant,
finished installation.
OLED Display:
3.The organic light emitting diode display is a highly functional and vivid multi-line display.
Now Playing/Menu Display:
4.This portion of the display serves two functions: In normal operation, it indicates the artist,
station, metadata, and other source information, and in Menu mode, it displays multiple lines of information for browsing
purposes.
Volume Level Indicator:
5.This bar graph indicates the audio volume level when the Control Pad is in normal play mode.
When in Menu Mode, it indicates the playback status of digital music files from the M3 audio server or iPod.
Power:
6.This button turns the local zone on and off and has the ability to turn all zones off simultaneously.
Menu:
7.Menu serves as access to music browsing, presets, and favorites, as well as specific zone and system setting
parameters.
Play/Pause:
8.This IR - programmable button toggles between the play and pause functions of the chosen source. When using
the T2G Tuners, this button toggles through the Tuner's receive modes. A third “press and hold” function can also be assigned
to this button for additional functionality.
OK:
9.The OK button serves a dual function. In normal play mode, it scrolls through the available audio sources. In Menu mode, it
is used to select the highlighted menu item.
Forward/Reverse:
10.This is an IR - programmable button for simple source transport functions. Typically, it would track forward
and back or tune up and down. A third “press and hold” function can also be assigned to this button for additional
functionality.
Arrow Up and Down:
11.These arrows have a dual function. In normal play mode, they control the volume level up and down. In
Menu
mode, they scroll up and down through menu selections.
IR Receiver:
12.The Control Pad has a built-in IR receiver for complete wireless control of all the audio source equipment.
5
NV-GRC1 Remote Control
1.Power:
Each zone can be turned on and off, or all
zones can be turned off with this button.
2.This serves two functions. In normal
Volume:
operation mode, it is a volume control, but when
you are using the menu features of the Control Pad,
it allows scrolling up and down.
3.These buttons are currently
Function Buttons:
inactive and designed for future use.
4.These IR programmable
Forward and Reverse:
buttons are designed for forward and reverse
functions.
5.A function of the Essentia System is the
Favorites:
ability to access user defined favorites for easy
access. The first twelve are directly accessible using
the GRC1 Favorites buttons.
6.This button allows access to the Display menu
DISP:
available at each Control Pad.
7.This LED (Light Emitting Diode) lights
Function LED:
to indicate a button push.
8.The GRC1 remote provides a discrete mute
MUTE:
function to quickly silence the zone's output.
9.This is another dual function button. In
SOURCE/OK:
normal playback mode it scrolls through the
sources, or in menu mode it selects a highlighted
menu choice.
10.This IR programmable button toggles
Play/Pause:
between the play and pause functions of the chosen
source. When using the T2G Tuners, this button
toggles through the Tuners’ receive modes.
11.This button enters the menu features of the
MENU:
Control Pad. When in Menu, mode the Volume up
and down buttons scroll through the menu choices.
12.This allows access to the sleep timer mode.
Sleep:
13.These buttons are currently inactive.
G1 and G2:
They are designed for future use.
4
5
6
1
2
3
PWR
HOLD
ALL OFF
VOLUME
SOURCE/OK
F1F2
F3F4
FAVORITES
1
4
789
10
MENU
DISP
G1
NV-GRC1
REMOTE CONTROL
11
7
MUTE
8
9
10
3
2
5
6
12
11
SLEEP
G2
12
13
6
Installing the Essentia System in Your Home
I. Prewire
The Essentia System uses CAT5 cable for Control Pad control and either two or four-conductor 16-gauge speaker wire. All the wire
is “homerun” from each zone to the location of the Essentia amplifier and Audio Source equipment.
Complete CAT5 Crimping Instructions
IR Active
Control Data Bus+
+20V Power
Ground
Control Data Bus-
Ground
Pair 1
Pair 3
IR Data
Pair 4
The NuVo audio systems require CAT5, unshielded, twisted
pair (UTP) for communication between the Control Pads and
the main amplifier unit. Each end of the wire is terminated
with an RJ45 connector.
The Essentia System can accommodate 2,000 total feet of
CAT5 cable. For the most reliable operation, it is best that no
single run of CAT5 exceeds 250 feet.
The correct wiring scheme for the CAT5 cable is standard
EIA/TIA 568A, or 568B. Properly terminating the CAT5 cable
is crucial for the operation of the system. It is very
important to use a good quality crimp tool, and test each
end to end run with a CAT5 wire tester to insure that your
system operates flawlessly, Fig.1.
Step-by-Step Crimping Instructions:
1.Stripa2to3inch portion of the insulation,
exposing the 4 twisted pairs.
2.Untwist the wires and fan them out
individually. Arrange the wires into the
correct color scheme as shown in Fig. 1.
3.Flatten the wires in their correct order and trim
them evenly across the top. Most crimp tools have
a wire trimmer built-in. It is best to trim the wires
to about ½” in length.
4.While holding the wires flat between your thumb
and forefinger, insert the wires into the RJ45
connector so each is in its own slot. Push the wire
into the RJ45 so all 8 conductors touch the end of
the connector. The insulation jacket should
extend beyond the crimp point of the RJ45.
5.Insert the RJ45 into the crimp tool receptacle and
squeeze the tool firmly. Note that a ratchet type
tool should tighten down until it no longer clicks.
6.The RJ45 should be firmly crimped to the CAT5
insulation. It is necessary that the color scheme
be repeated identically on each end of the wire.
7.Test each termination with a CAT5 Tester before
completing the installation.
Top view with
tab down.
12345678
Pair 2
Wires insert from
this end.
Fig. 1: EIA 568A and 568B wiring scheme for CAT5 Cable
Pin#568A
1. Green Stripe
2. Green
3. Orange Stripe
4. Blue
5. Blue Stripe
6. Orange
7. Brown Stripe
8. Brown
Note: Colors listed as “stripe” are a white wire
with a colored stripe.
Pin#568B
1. Orange Stripe
2. Orange
3. Green Stripe
4. Blue
5. Blue Stripe
6. Green
7. Brown Stripe
8. Brown
Step 1Step 2Step 3
Step 4
Step 5Step 6
7
II. Terminating the Speaker Wire (Fig. 2)
All NuVo Systems operate across a “homerun” wiring scheme
using CAT5 for the zone's Control Pad communication and
control, and a separate run of speaker wire for each zone.
The Essentia operates differently in that its zone speaker
wire termination is made at the Allport hub. The suggested
wire for this purpose is 16-gauge, 2- or 4- conductor
speaker wire rated for in-wall use.
The termination is performed using a modular “Euro”
connector. Each conductor is screwed down to the Euro
connector and plugged into the appropriate zone speaker
connection on the back of the Allport. The proper
termination for each zone is Left channel: — and , and Right
channel: — and .
+
+
IThe order in which the CAT5 cables are plugged into the
jacks is irrelevant to the system's operation. Six modular
“Euro” connectors are used to terminate the speakers in
each zone, see Section II, Terminating the Speaker Wire.
Once the speaker and CAT5 terminations are complete, the
Allport can be installed.
Fig. 2
III. Installing the Essentia Amplifier
System setup works best when the amplifier is placed in the
same location as the audio source equipment. This is
typically in an audio rack, entertainment center, or a closet
dedicated to housing the home audio/video equipment. To
insure cool, reliable operation, we highly recommend
allowing one empty rack space above a Main or an Expander
amplifier unit. Also, insure there is ventilation around the
whole rack location.
The amplifier should be plugged in and the blue Standby LED
should be lit before proceeding with the remaining
installation. This activates protective circuitry for the
internal components.
IV. Installing the NV-E6GMAP-DC Allport (Fig. 3)
The Allport is a multi-connection hub designed to accept all
the CAT5 and speaker wires from all zones of the Essentia
System. The location of the Allport should be determined by
the location of the Essentia amplifier. It is best to place it in
a wall behind the amplifier that can be easily accessible if
necessary.
The Allport is designed to fit into most any dual-gang
mounting ring, and has two sets of terminations on the
backside. Eight RJ45 jacks are meant for the Control Pads in
up to six zones, with one reserved for an additional Control
Pad and another for a “link” jack used for expansion from six
to twelve zones.
Fig. 3
LEFT
-
+
+
+
+
+
+
+
LEFT
+
RIGHT
-
+
RIGHT
+
+
+
+
+
+
+
8
V. Connecting the Allport to the Essentia Amplifier (Fig. 4)
Once installed, the front of the Allport has three “Device”
RJ45 jacks for CAT5 connections from the NuVoNet Suite
components, and an RJ45 jack labeled “NuVoNet” which
must be connected to the “NuVoNet” input on the back of
the Essentia amplifier. This is necessary for Control Pad
communication, regardless the use of the NuVoNet Suite
components. Once connected, the Control Pads are ready to
communicate with the System. The Essentia System is
shipped with a six-foot pre-terminated CAT5 network cable,
or you can purchase one if a different length is required.
The speaker connection is made with the 25-pin Allport
Cable. The modular speaker connectors must be plugged into
the appropriate speaker connections on the back of the
Allport.
Setting up NuVo Sources for use with NuVoNet
A feature of the Essentia System is its ability to
automatically communicate with the T2G family of tuners,
the M3 Audio Server, and the Wired and Wireless NuVoDocks
for iPod. The communication happens through the Allport
connection hub across a communication protocol called
NuVoNet. Although software programming is not necessary
for this function, configuring the installation through the
Configurator Software prior to installation has distinct
advantages, see
X. Essentia Configurator Software.
When the T2G tuners or M3 Server are plugged in for the first
time, they will display a prompt to select a source input
number for the Essentia. For NuVoNet to communicate
properly, you should have already connected the NuVoNet
components to one of the three “Peripheral Device” inputs
on the face of the Allport.
VI. Attaching Audio Source Equipment (Fig. 5)
Each piece of audio equipment is connected to the Essentia
amplifier with standard stereo RCA cables. Attach an RCA
cable to the corresponding audio output on the source
equipment and to the desired source input on the back of
the Essentia amplifier. The numbered input for each source
is important in the configuration of the system. This will be
covered in detail in the Essentia Configurator portion of this
manual.
Using the Fixed and Variable Lineouts
The Zone 1 and 2 outputs have 3.5mm stereo pre-amp
lineouts attached to them. Their purpose is to provide the
zone’s current audio selection signal to an additional
amplifier. Both versions, fixed (a constant signal that
requires a volume control separate from the NuVo zone
Control Pad) and variable (a signal that varies in level
relative to the volume setting on the NuVo zone Control Pad)
are both simultaneously active and require no external
switch for use.
Each output has an attached voltage trigger output that
allows the attached amplifier to be triggered from a voltage
presented when the zone Control Pad is turned on. The
voltage trigger is removed when the zone is truned off.
Fig. 4
IROUTPUTS
1
23456
ALLPORTCONNECTION
ALLPORTCONNECTION
STATUS
MUTE
SUM
LINK
NuVoNet
RS232
Fig. 5
78 9101112
USEONLYNuVo
USEONLYNuVo
NV-T2PAS
NV-T2PAS
POWEREDANTENNASYSTEM
POWEREDANTENNASYSTEM
IN
FIXED VAR
TRIG
ZONE
7
ZONE
8
AUXINAUXIN
AUDIOOUTAUDIO OUT
TRIGGER
TRIGGER
L
ON=+12V
ON=+12V
AUDIO
AUDIO
R
OUTPUT
OUTPUT
TUNERBTUNERBANTENNAINPUT
T2G AM/FM and XM Tuners
Each of the T2G Tuner components houses two individual
AM/FM or Satellite receivers, which have their own display
on the front panel. Once the T2G is plugged in and the
NuVoNet CAT5 is connected to the Allport, the initial display,
OPERATING MODE
choices are
SOURCE 3, SOURCE 2,SOURCE 1.
will appear for each tuner. Below this, the
STAND ALONE, SOURCE 6, SOURCE 5, SOURCE 4,
andStand Alone is
automatically highlighted at initial startup. Selecting the
appropriate Essentia source input is accomplished by
turning the Select knob for each tuner counter-clockwise
until the desired source input number is highlighted. It is
selected by pushing the Select knob. Once this is complete,
the Essentia System NuVoNet will recognize that source.
9
M3 Audio Server and T2SIR Dual Sirius Ready Tuners
At initial startup, the front panel display will display a
prompt screenBelow this header are
Status, all outputs.
three lines of text representing each of the three audio
outputs labeled A, B, and C. Output A will be highlighted and
it will display
SOURCE.
Address, Output A,STANDALONE
readbelow this,will be
highlighted and the other choices will be
2. . .SOURCE 3,
and as you scroll using the down arrow,
SOURCE 4, SOURCE 5,SOURCE 6
OUTPUT A: PRESS OK TO SELECT NUVONET
When OK is selected, the top line of the display will
SOURCE 1, SOURCE
andwill appear. Highlight
the appropriate choice and press OK to select. This will set
the first channel music output. You will then be prompted to
repeat these steps for the remaining two channels.
NuVoDock for iPod
Both the Wired and Wireless NuVoDocks for iPod use a
simple rotary switch to set the appropriate source input. Up
to two Wireless NuVoDocks and six Wired NuVoDocks could
be used as individual sources through NuVoNet. The Wired
and Wireless NuVoDocks consist of a dock for iPod playback
and recharging as well as a receiver component designed to
communicate with NuVoNet. Prior to plugging the receiver
into the Essentia Allport, set the Source rotary switch to the
desired source number input. Once set, theEssentia Control
Pads will automatically display the iPod information when an
iPod is plugged into the NuVoDock. Each NuVoDock and
receiver must have a separate source number selected.
Note that although the NuVoDock system has a 16 position
rotary switch for source input, only positions 1 – 6 are used.
The two SUM outputs will flash any IR command that is sent
from any of the zones. This is most commonly used with an
IR blaster designed to flash IR commands to a variety of
components.
Fig. 6
STATUS
NuVoNet
MUTE
LINK
IR OUTPUTS
1
23456
ALLPORTCONNECTION
ALLPORT CONNECTION
COMPACT
RS232
SUM
dISC
NuVo T2G Tuner Direct Numeric Access (Fig. 7)
The NuVo T2G Tuners have the ability for direct IR access to
numeric station tuning. This can be done through the T2G
remote control or using a third party remote control that has
been taught the T2G IR codes. To allow this control, it is
necessary to link the Essentia SUM IR output to the Direct IR
input on the T2G using a stereo 3.5mm (1/8”) mono patch
cable. Once the connection is made, the T2G will respond to
the numeric IR commands issued through the Essentia
Control Pad IR receivers.
VII. Connecting the IR Emitters for Third-Party Source
Components (Fig. 6)
IR commands for the source equipment are transferred from
the Essentia amplifier to the source equipment using the
mini IR mouse emitters. Six of these are supplied with your
Essentia System. The emitter is plugged into the
corresponding source IR output on the Essentia and then
placed over the IR receiver window on the source
component. The IR outputs are individually routed to
sources 1-6.
10
Fig. 7
T2G Tuner IR Input
IRPASS-THRU
IRINPUT
NuVoNet
OUTIN
SYSTEM
Essentia IR Ouput
IR OUTPUTS
23456
1
ALLPORTCONNECTION
ALLPORT CONNECTION
Model NV-T2DF
DualXM Tuner
NuVoTechonlogies LLC•
www.nuvotechnologies.com
RS232
SUM
RS232
CincinnatiOhio USA
STATUS
NuVoNet
MUTE
LINK
VII. Expanding Essentia to 12 Zones (Fig. 8)
Six additional listening zones can be added to the Essentia
System using the Essentia Expander System, NV-E6GXS. The
expander requires the use of the Link RJ45 connection on the
main amplifier. This is connected to the corresponding Link
RJ45 connection on the expander amplifier. All of the upper
zone control commands from the main unit's NuVoNet or
RS232 command input are transferred through this
connection. The NV-RCA3 Y-adapter cables included with
the expander unit allow a parallel connection of the left and
right source output to the corresponding source inputs on
both amplifier units, fig. 8a.
The expansion requires the installation of the expander
Allport included with the expander system. The expander
Allport is the connection for the additional zone Control
Pads, up to seven, and the additional zone speakers. A
second Allport cable must be attached from the expander
Allport to the expander amplifier and a short CAT5 jumper
cable, included with the expander system is used on the
back of the two Allports to integrate all of the System’s
Control Pads into one NuVoNet connection to the main
amplifier, Fig. 8b.
Fig. 8c
Once these connections are complete, the Control Pads can
be addressed for a twelve-zone system.
Note: If you are using the Remote (wired) or Wireless
versions of the NuVoDocks for iPod, it is necessary to use a
female to male adaptor. These are readily available and are
not supplied with the NuVoDock system, fig. 8c.
Fig. 8a
NV-RCAY3 “Y” cable
12 3456
12 3456
USEONLYNuVo
USEONLYNuVo
NV-T2PAS
NV-T2PAS
POWEREDANTENNASYSTEM
POWEREDANTENNASYSTEM
IN
Essentia G Expander
FIXED VAR
ZONE
7
ZONE
8
Essentia G Main
FIXED VAR
TRIG
ZONE
1
ZONE
2
Audio Source
AUDIOOUTAUDIOOUT
TRIGGER
TRIGGER
ON=+12V
ON=+12V
AUDIO
AUDIO
OUTPUT
OUTPUT
TUNERBTUNERBANTENNAINPUT
TRIG
Fig. 8b
+
+
+
+
+
+
E6GXAP-DC
Expander Allport Hub
+
+
+
+
+
+
+
+
+
+
+
+
E6GMAP-DC
Main Allport Hub
+
+
+
+
+
+
Fig. 8
ALLPORTCONNECTION
11
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.