NuTone QTXE080, QTXE110, QTXE090C, QTXEN110, QTXEN080 Instructions Manual

...
MODELS QTXE080 • QTXEN080 • QTXE090C • QTXE110 • QTXEN110 • QTXE1102
QTXE SERIES ULTRA SILENT
READ AND SAVE THESE INSTRUCTIONS
Page 1
TM
FANS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip­ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori­ties.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear­ance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Broan Models 78V and 78W may cause a motor humming noise.
Use of speed controls other than the
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard­ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further informa­tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTXE080 • QTXEN080 • QTXE090C • QTXE110 • QTXEN110 • QTXE1102
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
Page 2
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Housing mounted any­where between I-joists using hanger bars.
Housing mounted to joists.
Housing mounted anywhere between trusses using hang­er bars.
PLAN THE INSTALLATION
Housing mounted anywhere between joists using hanger bars.
Housing mounted anywhere between trusses using hang­er bars.
Seal duct
joints with
tape.
6-IN.
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
OR
WALL CAP*
(with built-in
damper)
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
6-IN. ROUND
*Purchase separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
DUCT*
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Plan to supply the unit with proper line voltage and appropriate power cable.
MODELS QTXE080 • QTXEN080 • QTXE090C • QTXE110 • QTXEN110 • QTXE1102
INSTALL HOUSING & DUCT
1a. Mount
housing to joist or I-joist.
Use a pliers to bend
housing TABS out to 900. Hold housing in place so that the housing tabs contact the bottom of the joist. The housing mounts with four (4) screws or nails. Screw or nail housing to joist through lowest holes in each mounting flange, then through highest holes. NOTE: Mounting to I-JOIST (shown) requires use of SPACERS (included) between the highest hole of each mounting flange and the I-joist.
(use for mounting to I-Joist)
TABS
SPACER
I-JOIST
Page 3
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
NAIL (4)
Extend HANGER BARS to the width of the framing. Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
* To ensure a noise-free mount: Secure hanger bars together
with SCREWS or use a pliers to crimp mounting channels tightly around hanger bars.
SCREW (2)
*
BOTTOM EDGE
OF FRAMING
OR
1b. Mount housing anywhere between
trusses, joists, or I-joists using hanger bars.
Sliding hanger bars are provided to allow for accurate posi-
tioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24”.
TAB
SCREWS (4)
STD
HANGER
BAR (4)
Attach the MOUNTING CHANNELS to the housing using the SCREWS supplied. Make sure TABS face “up” as shown. Use the set of channel mounting holes (marked “STD”) to mount the housing flush with the bottom of the drywall. Use the other set of holes (not marked) to mount the housing flush with the top of the drywall.
MOUNTING
CHANNEL (2)
2. Attach damper/duct connector.
Snap damper /
duct connector onto housing. Make sure con­nector is flush with top of housing and damper flap falls closed.
3. Install 6-inch round duct­work.
Connect 6-inch
round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork con­nections to make them secure and air tight.
MODELS QTXE080 • QTXEN080 • QTXE090C • QTXE110 • QTXEN110 • QTXE1102
Page 4
CONNECT WIRING
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to wiring plate. Connect wires as shown in wiring diagrams.
INSTALL GRILLE
5. Finish ceiling.
Install ceiling material. Cut out around housing.
6. Attach grille to housing.
Squeeze grille
springs and insert them into slots on each side of hous­ing.
7. Push grille against
ceiling.
99045936A