Register your product
QTREN SERIES
online at www.nutone.ca
QUIET VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
MODELS QTREN090C • QTREN110C
Page 1
BB0007
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded
9. When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expenses.
10. When performing installation, servicing or cleaning this unit, it
is recommended to wear safety glasses and gloves.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further information
and requirements.
!
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See
“Connect Wiring” for details.
WARRANTY
BROAN-NUTONE CANADA INC.
Broan-NuTone Canada warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a period of three
(3) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone Canada will, at its option, repair or
replace, without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR
TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS AND
OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone Canada or an authorized representative), faulty installation or installation
contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified for
the express warranty.
BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or
telephone number stated below, (b) give the model number and part identification and
(c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Date of Installation Builder or Installer
Model Number and Product Description
For the location of your nearest Broan-NuTone Canada Inc. dealer:
Product model number • Date and proof of purchase • The nature of the difficulty
THREE-YEAR LIMITED WARRANTY
IF YOU NEED ASSISTANCE OR SERVICE
Dial Toll Free: 1-888-882-7626
Please be prepared to provide:
1140 Tristar Drive, Mississauga, Ontario L5T 1H9
Broan-NuTone Canada Inc.
Installer: Leave this manual with the homeowner.

TYPICAL INSTALLATIONS
ROOF
CAP
*
4-IN. ROUND
ELBOW(S)
*
4-IN.
ROUND
DUCT
*
WALL
CAP
*
*
Purchase
separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
Housing mounted
to I-joists.
BH0001A
Housing mounted
anywhere
between I-joists
using hanger
bars.
MODELS QTREN090C • QTREN110C
Page 2
Housing mounted
anywhere between
trusses using
hanger bars.
PLAN THE INSTALLATION
COOKING AREA
Do not install above or
inside this area.
Housing mounted
to joists.
Housing mounted
anywhere
between joists
using hanger
bars.
Housing mounted
anywhere between
trusses using
hanger bars.
45º
NOT FOR USE IN
A COOKING AREA.
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number of
elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
Cooking
Equipment
45º
Floor

INSTALL HOUSING & DUCT
MODELS QTREN090C • QTREN110C
Page 3
1a. Mount
housing to
joist or I-joist.
Use pliers to bend
housing TABS out
to 90°. Hold housing
in place so that
the housing tabs
contact the bottom
of the joist. The
housing mounts
with four screws
or nails. Screw or
nail housing to joist
through lowest holes
in each mounting
flange, then through
highest holes.
NOTE: Mounting to
I-JOIST (shown)
requires use
of SPACERS
(included) between
the highest hole of
each mounting flange and the I-joist.
(use for mounting to I-Joist)
OR
TABS
SPACER
I-JOIST
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
NAIL (4)
Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
*To ensure a noise-free mount: Secure hanger bars together
with SCREWS or use a pliers to crimp mounting channels
tightly around hanger bars.
*SCREW (2)
BOTTOM EDGE
OF FRAMING
1b. Mount housing anywhere between trusses,
joists, or I-joists using hanger bars.
Sliding hanger bars are provided to allow for accurate
positioning of housing anywhere between framing. They can
be used on all types of framing (I-joist, standard joist, and
truss construction) and span up to 24”.
SCREWS (4)
STD
HANGER
BAR (4)
BD0002
Attach the MOUNTING CHANNELS to the housing using the
SCREWS supplied. Make sure TABS face “up” as shown. Use
the set of channel mounting holes (marked “STD”) to mount the
housing flush with the bottom of the drywall. Use the other set
of holes (not marked) to mount the housing flush with the top of
the drywall.
MOUNTING
CHANNEL (2)
TAB
2. Attach
damper/duct
connector.
Snap damper/duct
connector onto
housing. Make
sure connector
is flush with top
of housing and
damper flap falls
closed.
3. Install 4-inch
round
ductwork.
Connect 4-inch
round ductwork
to damper/
duct connector.
Run ductwork
to a roof cap or
wall cap. Tape
all ductwork
connections
to make them
secure and air tight.