READ AND SAVE THESE INSTRUCTIONS
MODELS QTREN090C • QTREN110C
Page 1
BB0007
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded
9. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
10. When performing installation, servicing or cleaning this unit, it is recommended to wear safety glasses and gloves.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
!
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details.
WARRANTY
BROAN-NUTONE CANADA INC.
Broan-NuTone Canada warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three (3) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone Canada or an authorized representative), faulty installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified for the express warranty.
BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Date of Installation Builder or Installer
Model Number and Product Description
For the location of your nearest Broan-NuTone Canada Inc. dealer:
Product model number • Date and proof of purchase • The nature of the difficulty
THREE-YEAR LIMITED WARRANTY
IF YOU NEED ASSISTANCE OR SERVICE
Dial Toll Free: 1-888-882-7626
Please be prepared to provide:
1140 Tristar Drive, Mississauga, Ontario L5T 1H9
Broan-NuTone Canada Inc.
Installer: Leave this manual with the homeowner.
TYPICAL INSTALLATIONS
5A
BH0006A
ROOF CAP
*
4-IN. ROUND
ELBOW(S)
*
4-IN. ROUND DUCT
*
WALL CAP
*
*
Purchase
separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
Housing mounted to I-joists.
BH0001A
Housing mounted anywhere between I-joists using hanger bars.
MODELS QTREN090C • QTREN110C
Page 2
Housing mounted anywhere between trusses using hanger bars.
PLAN THE INSTALLATION
COOKING AREA
Do not install above or
inside this area.
Housing mounted to joists.
Housing mounted anywhere between joists using hanger bars.
Housing mounted anywhere between trusses using hanger bars.
45º
NOT FOR USE IN
A COOKING AREA.
The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Plan to supply the unit with proper line voltage and appropriate power cable.
Cooking
Equipment
45º
Floor
BJ0002
INSTALL HOUSING & DUCT
BD0001
MODELS QTREN090C • QTREN110C
Page 3
1a. Mount
housing to joist or I-joist.
Use pliers to bend
housing TABS out to 90°. Hold housing in place so that the housing tabs contact the bottom of the joist. The housing mounts with four screws or nails. Screw or nail housing to joist through lowest holes in each mounting flange, then through highest holes.
NOTE: Mounting to
I-JOIST (shown) requires use of SPACERS (included) between the highest hole of each mounting flange and the I-joist.
(use for mounting to I-Joist)
OR
TABS
SPACER
I-JOIST
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
NAIL (4)
Extend HANGER BARS to the width of the framing. Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
*To ensure a noise-free mount: Secure hanger bars together
with SCREWS or use a pliers to crimp mounting channels tightly around hanger bars.
*SCREW (2)
BOTTOM EDGE
OF FRAMING
1b. Mount housing anywhere between trusses,
joists, or I-joists using hanger bars.
Sliding hanger bars are provided to allow for accurate
positioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24”.
SCREWS (4)
STD
HANGER
BAR (4)
BD0002
Attach the MOUNTING CHANNELS to the housing using the SCREWS supplied. Make sure TABS face “up” as shown. Use the set of channel mounting holes (marked “STD”) to mount the housing flush with the bottom of the drywall. Use the other set of holes (not marked) to mount the housing flush with the top of the drywall.
MOUNTING
CHANNEL (2)
TAB
2. Attach damper/duct connector.
Snap damper/duct
connector onto housing. Make sure connector is flush with top of housing and damper flap falls closed.
3. Install 4-inch round ductwork.
Connect 4-inch
round ductwork to damper/ duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections to make them secure and air tight.