To reduce the risk of fire, electric shock, or injury to persons, observe the following:
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the ser­vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9 m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
7. Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a rep­utable electrician before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel (or operate inter­nal disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock or fire, or damage the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in any manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids are used or stored.
13. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
14. Install heater at least 6 inches from floor or any adjacent wall.
16. This product is designed for installation in ceilings up to a 12/12 pitch. Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
17. Do not connect heater to dimmer switch or speed control.
18. Ducted fans must always be vented to the outdoors.
19. This product must be grounded.
SAVE THESE INSTRUCTIONS
TIONS
MODEL QT9093WH
Page 2
INSTALLATION
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicin­ity of the heater.
CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
Refer to Figure 1.
1. Loosen two screws holding grille in place. Remove grille and set aside. Remove housing, switch assembly, hanger bar and mounting brackets from carton.
2. Loosen four (4) screws holding heater power unit in place. Remove heater power unit and set aside.
HEATER
SCREWS
13” DIA.
14” DIA.
FIGURE 2
HEATER
SCREWS
FIGURE 1
MOUNTING TO OPEN JOISTS IN NEW CONSTRUCTION
1. Install hanger brackets in keyhole slots in housing. Insert hanger bar through bracket opposite blower vent.
Refer to Figure 2.
2. Position housing between joists with exhaust vent in desired direction. Secure side hanger brackets and ends of adjustable hanger bar to joists with screws or nails. If joist spacing is greater than 16” O.C., construct framing to support sides of housing.
Refer to Figure 3.
3. Position housing against joists and secure with wood screws through keyhole slots in housing.
4. Loosen screws securing hanger brackets to housing and adjust height of housing so that bottom flange will be flush with finished ceiling. Tighten screws securely.
5. Attach 4” round duct and run ductwork to the outside through wall or roof.
FIGURE 3
WIRING
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
115-120 volts (20 amp circuit only), 12 gauge wire.
1. Remove desired knockout from junction box and install a box connector (not provided).
Refer to Figure 4.
2. Run 120vAC supply wiring to wall switch box. Run wiring from wall switch box to heater. Five conductors plus ground are required for independent operation of all functions.
3. When a thermostat or timer switch is used, connect at point marked “T” on Figure 4.
4. Make wiring connections using wire nuts. Connect ground wire under ground screw in junction box.
5. Push wiring back into junction box and install junction box cover being careful not to pinch wiring between cover and housing. Secure cover.
FIGURE 4
COMPLETING INSTALLATION
1. Reinstall the heater unit and tighten four (4) screws securely.
2. Plug fan and heater assemblies to receptacles on junction box cover.
3. Install a 100 watt lamp in light socket and 7 watt lamp in night light socket.
4. Place grille over grille mounting screws and tighten.
5. Check out all functions for proper operation.
INSTALLATION IN EXISTING CONSTRUCTION
Refer to Figure 5. NOTE: In existing construction, hanger bar and mounting
brackets are not used.
1. Determine desired location of heater. Area above heater must be free of plumbing and electrical wiring. There must be enough clearance above ceiling for heater housing and installation of duct and wiring.
2. Drill a small hole up through ceiling and insert a wire or nail to help in locating from above.
3. Locate hole from above. Center heater housing between joists and use the bottom flange of housing as a template to mark cutout. Cut out hole in ceiling.
4. Refer to Figure 3. Secure short pieces of 1” x 3” lumber (¾” nominal) to joists on either side of opening. Leave approximately ½” between top of ceiling so that flange of heater housing can slide under spacers. If joist spacing is greater than 16” O.C., cut spacers of 2” x 4” lumber to fit between housing and joists.
5. Place heater over opening and between spacers. From below, align housing so flange is flush with finished ceiling. Secure to spacers with nails or wood screws though keyhole slots. NOTE: If necessary, housing can be installed from below by removing vent blower, vent housing, and outlet box.
6. Install 4” duct and refer to previous section of these instructions for Wiring and Completing Installation.
2½”
75/8
5½”
FIGURE 5
MODEL QT9093WH
Page 3
OPERATION
Before using heater, make sure heater has been properly installed according to installation steps beginning with the “INSTALLATION” section on page 2.
MODEL QT9093WH
Page 4
MAINTENANCE
The following maintenance and cleaning tasks can be performed by the user. All other servicing must be performed by an autho­rized technician If you have any questions, please consult with our customer service department at: 800-558-1711.
TO REPLACE BULB
Use bulb rated up to 100 watts only and 7 watts only for night light.
LUBRICATION
The heater is permanently lubricated and never needs oiling or disassembly.
CLEANING
Clean heater once a month as follows:
1. Turn off power at service panel.
2. Make sure heating element is cool.
3. Use a soft brush attachment to gently vacuum grille openings
or wipe grille clean with a soft cloth.
4. Restore power.
CAUTION: METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
MODEL QT9093WH
Page 5
MODÈLE DE LUXE QT9093WH
MODÈLE QT9093WH
Page 6
HEAT-A-VENTLITE
MD
LIRE CES DIRECTIVES ET LES CONSERVER
INSTRUCTIONS IMPORTANTES
LIRE TOUTES LES INSTRUCTIONS AVANT D’INSTALLER OU D’UTILISER CET APPAREIL DE CHAUFFAGE.
Observez les directives ci-dessous afin de réduire les risques d’incendie, de choc électrique ou de blessures corporelles :
2. Avant de procéder à l’entretien ou au nettoyage de l’appareil, coupez l’alimentation du panneau électrique et verrouillez l’interrupteur principal afin d’empêcher que le courant ne soit accidentellement rétabli. S’il est impossible de ver­rouiller l’interrupteur principal, fixez solidement un message d’avertissement, par exemple une étiquette, sur le panneau électrique.
3. La pose de l’appareil et les travaux d’électricité doivent être effectués par des personnes qualifiées conformément à la réglementation en vigueur, notamment les normes de la con­struction ayant trait à la protection contre les incendies.
4. Veillez à ne pas endommager le câblage électrique ou d’autres équipements non apparents lors de la découpe ou du perçage du mur ou du plafond.
5. Cet appareil de chauffage devient chaud en fonctionnant. Pour ne pas vous brûler, évitez tout contact de la peau nue avec les surfaces chaudes. Gardez les objets combustibles, tels que les meubles, oreillers, articles de literie, papiers, vêtements, etc. et rideaux à au moins x mètre (x pieds) de l’avant de la chaufferette.
6. Il faut faire extrêmement attention lorsqu’une chaufferette est utilisée par des enfants ou des personnes invalides ou près d’eux et si l’appareil est laissé en marche sans surveillance.
8. Ne l’utilisez pas à l’extérieur.
9. Pour débrancher la chaufferette, mettez les commandes sur arrêt et coupez l’alimentation du circuit au panneau élec­trique (ou utilisez l’interrupteur interne, s’il y en a un).
10. N’insérez et ne laissez pénétrer aucun corps étranger dans les ouvertures de ventilation ou de sortie d’air au risque de provoquer un choc électrique, un incendie ou d’endommager la chaufferette.
12. La chaufferette contient des pièces brûlantes et qui produisent des arcs ou des étincelles à l’intérieur. Ne l’utilisez pas dans un endroit où de l’essence, de la peinture ou des vapeurs ou liquides inflammables sont utilisés ou entreposés.
15. Pour éviter un choc électrique: Ne pas installer l’appareil dans une enceinte de baignoire ou d’une douche ou tout autre endroit où il pourrait entrer en contact avec de l’eau. Ne placez jamais un interrupteur où il peut être accessible depuis une baignoire ou une douche.
16. Ce produit est conçu pour une installation dans les plafonds jusqu’à une hauteur 12/12. Le raccord de conduit doit pointer vers le haut. NE PAS MONTER CE PRODUIT DANS UN MUR.
17. Ne pas brancher chauffe à gradateur ou contrôle de vitesse.
18. Les ventilateurs avec conduits doivent toujours être évacués vers l’extérieur.
19. Ce produit doit être mis à la terre.
CONSERVER CES INSTRUCTIONS