NuTone QT150 User Manual

Architectural & Engineering Specifications
March 2004
QuieTTest Twin
Blower Ventilator
(For Ceiling Use)
MODEL: QT150
DESCRIPTION
For bathrooms up to 150 sq. ft. (13.9M2), other rooms up
to 200 sq. ft. (18.56M2).
Sturdy brown-enamel steel housing is lined with sound-deadening foam for quiet operation.
Motor plugs into prewired junction box.
Vents horizontally or vertically with 31⁄4" x 10" duct.
Duct collar with damper included.
Installs between 16" O.C. joists with slotted mounting brackets. Slots on the sides of the housing provide alternative mounting.
Wiring knockouts located on the top and back of the housing.
Refer to NuTone's catalog for a complete line of accessories to effectively adapt this Fan to your construction requirements.
Energy Star®Qualified.
DESIGN FEATURES
HVI Air Delivery: 160 CFM (75.5LS). HVI Sound Level: 2.5 Sones Dimensions: Housing: 141⁄4" L x 10" W x 9" D
(36.2CM X 25.4CM X 22.8CM). Grille: 161⁄2" L x 123⁄32" W x 5⁄8" D (41.9CM X 30.7CM X 1.6CM).
Material & Finish: Housing: Galvanize steel.
Grille: White Polymeric. Motor: Thermally protected. Blower Wheel: Aluminum, electronically balanced. Duct Size: 31⁄4" x 10". Electrical Rating: 120v, 60Hz, 0.6Amp
INSTALLATION
• Not for use in kitchens.
• Complete installation instructions are included with each unit.
ARCHITECT'S SPECIFICATIONS
Twin-Blower Ventilator shall be Model QT150 as manufactured by NuTone according to listed specifications. Unit shall ventilate 160 CFM at a sound level of 2.5 Sones. Housing shall measure 141⁄4" x 10" x 9" deep and connect to 31⁄4" x 10" duct.
CERTIFIED TEST DATA
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements. This NuTone model is listed by Underwriters' Laboratories Inc. and Certified by the Canadian Standards Association (CSA).
The air delivery of a ventilating system may be determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of duct diameter, i.e., a 4 inch diameter duct elbow equals 4 feet equivalent duct length and an 8 inch diameter duct elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent duct length.
3. Locate the intersection of the fan performance curve
and the total equivalent duct length curves and draw a vertical line down to the CFM scale and read the system air performance. (NOTE: 31⁄4" x 10" duct equals 6 inch diameter duct.)
AIR PERFORMANCE CURVE – Horizontal
(6 In. Duct to 10 Foot Lengths)
AIR PERFORMANCE CURVE – Vertical
(6 In. Duct to 10 Foot Lengths)
3 1/4" x 10"
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9
Printed in U.S.A.
STATIC PRESSURE INCHES OF WATER
CFM
0.05
185 162 158 142 120
0.1
160
LS
87.3 76.4 74.5 67.0 56.6 – 75.5
.125 0.15 0.2 0.25 0.3 0.35 0.4 0.45
STATIC PRESSURE INCHES OF WATER
CFM
0.05
185 169 156 140 120
0.1
162
LS
87.3 79.7 73.4 66.0 56.6 – 76.4
.125 0.15 0.2 0.25 0.3 0.35 0.4 0.45