NuTone 671, 671R, 672R User Manual

TO REGISTER THIS PRODUCT, VISIT WWW.NUTONE.COM
Ventilation Fan
MODELS: 671R & 672R
    The Exhaust Fan consists of the housing, power unit/blower  assembly (motor, wheel, mounting plate), grille and duct collar.
READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
DUCT COLLAR
COLLIER DE GAINE
COLLARÍN DE TUBO
FAN MUST NOT BE INSTALLED IN A CEILING INSULATED TO A VALUE GREATER THAN R-40.
FOR BEST RESULTS
    When installing the Exhaust Fan in a new construction site,  install the housing during the rough-in construction. The blower  unit and grille should be installed after the finished ceiling is in  place.     To install the Exhaust Fan in an existing finished building, an  accessible area is required above the planned location (attic or  crawl space).
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A.  Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the  manufacturer.
B.  Before servicing or cleaning unit, switch power off at service 
panel and lock service panel to prevent power from being  switched on accidentally. When the service disconnecting means cannot be locked,  securely fasten a prominent warning device, such as a tag,   to the service panel.
CAUTION: For general ventilating use only. Do not use to exhaust 
hazardous or explosive materials and vapors.      WARNING: To reduce the risk of fire or electric shock, do not  use this fan with any solid-state speed control.
HOUSING
BOITER CUBIERTA
SLOTS
FENTES RANURAS
TABS
PATTES LENGÜETA
MOUNTING TAB
PATTES DE MONTAGE
LENGÜETA DE MONTAJE
POWER UNIT/BLOWER ASSEMBLY
ENSEMBLE MOTEUR/ VENTILATEUR
CONJUNTO DE UNIDAD DE POTENCIA/ SOPLADOR
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A.  Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes  and standards, including fire-rated construction.
B.  Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel  burning equipment to prevent back drafting. Follow the  heating equipment manufacturer’s guideline and safety  standards such as those published by the National Fire  Protection Association (NFPA), and the American Society  for Heating, Refrigeration and Air Conditioning Engineers  (ASHRAE), and the local code authorities.
GRILLE
GRILLE REJILLA
FIGURE 1
C.  When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities. D.  Ducted fans must always be vented to the outdoors. E.  If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application and be connected 
to a GFCI (Ground Fault Circuit Interrupter) protected branch 
circuit. F.  NEVER place a switch where it can be reached from a tub or
shower.
1
PLANNING DUCTWORK AND WIRING
Ductwork
1. Use 4” round duct.
2.  Plan to run duct from discharge opening of fan to the  outside. For best fan performance, make the duct run as  short as possible and use a minimum number of elbows.
3. Use optional ducting accessories as required.
Wiring
    Plan to run 120vAC house wiring (with ground) from the  power source through a standard wall switch.
Preparation
1.  Refer to Figure 1. Remove blower/power unit assembly  from the housing.
    (a) Unplug the power unit.     (b)  Remove the screw (located next to plug-in receptacle) 
which holds blower/power unit mounting plate in place.  Do not misplace this screw.
    (c)  Lift the mounting plate at the end near the plug-in 
receptacle until blower wheel clears the scroll.
    (d)  Remove plate by pulling its tabs out of slots in the 
housing. Set blower/power unit aside until needed.
2. Remove one of the wiring knockouts from housing.
MOUNTING THE HOUSING
Mounting Using Mounting Tabs  Refer to Figure 2.
1.  Locate fan housing next to ceiling joist.
2.  Using wood screws (not provided) loosely attach the  housing to ceiling joist through the keyhole slots in  mounting tabs.
3.  Adjust housing so that it will be flush with the finished  ceiling. For the grille to fit properly, the housing’s rim  must  not extend beyond finished ceiling surface.
4.  When housing is properly adjusted, tighten screws in slots.
FLANGES
COLLERETTES
BRIDAS
WIRING KNOCKOUT
OUVERTURES PRÉAMORCÉES
AGUJERO CIEGO DE CABLEADO
HANGER BARS (SOLD SEPARATELY)
BARRES DE SUSPENSION (VENDUES SÉPARÉMENT)
BARRAS DE SUSPENSIÓN (SE VENDEN POR SEPARADO)
DUCT COLLAR
COLLIER DE GAINE COLLARÍN DEL TUBO
MOUNTING TAB
PATTES DE MONTAGE LENGÜETA DE MONTAJE
FIGURE 2
Mounting Using Hanger Bars (hanger bars sold separately, order model HB4) Refer to Figure 3.
1.  Insert hanger bars in slots provided in housing.
2.  Locate fan housing between joists so that the bottom of the  housing is even with the planned finished ceiling. Extend  the hanger bars to the joists.
3.  Use screws or nails (not provided) to secure hanger bars to  ceiling joists.
INSTALLING DUCTWORK
1.  Refer to Figure 2. Place duct collar over flanges at  discharge opening of fan. Secure collar by snapping tabs  into slots in flanges.
2.  Run 4” round duct from outside to fan’s discharge opening.
3. Connect duct to fan’s duct collar.
WIRING
All wiring must comply with local codes and unit must be properly grounded.
1.  Run 120vAC house wiring (with ground) from wall switch to  fan location.
2. Pull wire through access hole and into junction box.
3.  Refer to Figure 4. Use approved wire nuts to connect  house supply wires to fixture as follows: white to white;  black to black. Connect green or bare ground wire to green  ground lead.
JUNCTION BOX
BOÎTE DE JONCTION
CAJA DE CONEXIONES
STANDARD WALL SWITCH (NOT INCLUDED)
INTERRUPTEUR MURAL STANDARD (NON INCLUS)
INTERRUPTOR DE PARED ESTÁNDAR (NO SE INCLUYE)
120vAC, 60Hz HOUSE POWER
COURANT DOMESTIQUE 120V CA, 60 Hz
ELECTRICIDAD DOMÉSTICA: 120 V CA, 60 Hz
2
FIGURE 3
GREEN GROUND LEAD
VIS VERTE DE MISE À LA TERRE
HILO VERDE DE CONEXIÓN A TIERRA
SWITCH BOX
BOÎTE D’INTERRUPTEUR CAJA DEL INTERRUPTOR
FIELD GROUNDING WIRE
FIL DE MISE À LA TERRE HILO DE CONEXIÓN A TIERRA
FIGURE 4