N-Tron SER-485-FXC Quick Start Guide

SER-485-FXC_0710 R1
11.. CChheecckk ffoorr RReeqquuiirreedd HHaarrddwwaarree
SER-485-FXC Fiber Optic Converter This Quick Start Guide Additional Items Required but not included
o A 10 to 48 VDC Power Supply. o Serial Cable o Multi-Mode Fiber Optic Cable with ST
Connectors (62.5 / 125 micro-meter).
22..
IInnffoorrmmaattiioonn –– UULL CCllaassss 11 DDiivv 22
1. Power, input /output (I/O) wiring must be in accordance with Class 1 Division 2 wiring methods [Article 501.10(B) of the National Electric code, NFPA70] and in accordance with the local authority having jurisdiction.
2. Maximum ambient air temperature 80° C.
3. WARNING – EXPLOSION HAZARD: SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABLITY FOR CLASS 1, DIVISION 2.
4. WARNING – EXPLOSION HAZARD: WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES
5. WARNING – EXPLOSION HAZARD: DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
6. WARNING – THIS APPARATUS IS SUITABLE FOR
USE IN CLASS 1 DIVISION 2, GROUPS A, B, C, AND D, OR UNCLASSIFIED AREAS.
66..
PPoowweerr CCoonnnneeccttiioonn
1. Power requirements are10 to 48 VDC @ 0.2A Follow polarity shown on label.
77.. WWiirriinngg EExxaammppllees
s
RS-485 2-Wire
Quick Start Guide
SER-485-FXC
Triple Isolated RS-232 to
Multi-Mode Fiber Converter
33..
FFrroonntt PPaanneell,, SSwwiittcchheess,, TTeerrmmiinnaall BBlloocckk
44.
.
RRSS--442222//448855 MMooddee,, TTeerrmmiinnaattiioonn &&
BBiiaass DDIIPP SSwwiittcchh SSeettttiinnggss
55..
RRSS--442222//448855 TTiimmee OOuutt
Pre-defined timeouts are set using switches 8 through 11. Resistor selectable baud rates are set by inserting a through-hole resistor (R-9) on the circuit board.
Timeout selections are equal to one character time at the indicated baud rate. Setting the converter to 9600 will generally work at 9600 and higher baud rates. In RS-422
mode, timeouts are not required.
Put
N-Tron Corp.
820 S. University Blvd. Suite 4E, Mobile, AL 36609
PH: 251-342-2164 · FAX: 251-342-6353
RS-485 2-Wire Continued
RS-422/485 4-Wire
RS-232
Multi-drop Ring
Maximum Converters in a Multi-drop Ring
Baud Rate
RS-232
RS-422/485
≤19.2 kbps
32
32
37.4 kbps
16
24
115.2 kbps
2
8
99.. RRSS--223322 LLooooppbbaacckk TTeesst
t
1. Configure the converter for RS-232.
2. Set DIP Switch position 12 to OFF.
3. Cross connect the fiber optic transmitter to the fiber optic
receiver.
4. Connect a PC to the serial port.
5. Using hyper terminal or similar program, connect to the
appropriate COM port. Ensure hyper terminal local echo is off.
6. Transmit data. If the same character string is returned, the
test is good.
88..
FFiibbeerr OOppttiicc
Point-to-Point
SER-485-FXC_0710 R1
N-Tron Corp.
820 S. University Blvd. Suite 4E, Mobile, AL 36609
PH: 251-342-2164 · FAX: 251-342-6353
Loading...