Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Input Voltage, Pin 3 2 V
p–p
Supply Voltage, Pin 4 10V
Output Voltage, Pin 8 13V
Voltage at All Other Pins Vs to Gnd
Output Current, Pin 8 30 mA
Package Dissipation 500 mW
Operating Temperature Range (T
A
) −25˚C to +125˚C
Storage Temperature Range −55˚C to +150˚C
Soldering Information
Dual-In-Line Package
Soldering (10 sec.) 260˚C
Small Outline Package
Vapor Phase (60 sec.) 215˚C
Infrared (15 sec.) 220˚C
See AN-450 “Surface Mounting Methods and Their Effect
on Product Reliability” for other methods of soldering
surface mount devices.
Electrical Characteristics
Test Circuit, T
A
=
25˚C, V
s
=
5V, RtCt
#
2, Sw. 1 Pos. 0, and no input, unless otherwise noted.
Symbol Parameter Conditions Min Typ Max Units
I4 Power Supply
Current
RtCt
#
1, Quiescent
or Activated
V
s
=
2V 0.3
mAdcV
s
=
5V 0.5 0.8
V
s
=
9V 0.8 1.3
V3 Input D.C. Bias 0 mVdc
R3 Input Resistance 40 kΩ
I8 Output Leakage 1 100 nAdc
f
0
Center Frequency,
F
osc
÷
2
RtCt
#
2, Measure Oscillator
Frequency and Divide by 2
V
s
=
2V 98
kHzV
s
=
5V 92 103 113
V
s
=
9V 105
∆f
0
Center Frequency
Shift with Supply
1.0 2.0
%
/V
V
in
Input Threshold Set Input Frequency Equal to f
0
Measured Above, Increase Input Level
Until Pin 8 Goes Low.
V
s
=
2V 11 20 27
mVrmsV
s
=
5V 17 30 45
V
s
=
9V 45
∆V
in
Input Hysteresis Starting at Input Threshold, Decrease Input
Level Until Pin 8 goes High.
1.5 mVrms
V8 Output ’Sat’ Voltage Input Level
>
Threshold
Choose RL for Specified I8
I8=2 mA 0.06 0.15
Vdc
I8=20 mA 0.7
L.D.B.W. Largest Detection
Bandwidth
Measure F
osc
with Sw. 1 in
Pos. 0, 1, and 2;
V
s
=
2V
71115
%
V
s
=
5V
11 14 17
V
s
=
9V
15
∆BW Bandwidth Skew
0±1.0
%
f
max
Highest Center
Freq.
RtCt#3, Measure Oscillator Frequency and Divide by 2
700 kHz
V
in
Input Threshold at
f
max
Set Input Frequency Equal to f
max
measured Above,
Increase Input Level Until Pin 8 goes Low.
35
mVrms
Note 1: Absolute Maximum Ratingsindicatelimitsbeyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Electrical Characteristics state DC and AC electrical specifications under particular test conditions which guarantee specific performance limits. This assumes that the device is within the Operating Ratings. Specifications are not guaranteed for parameters where no limit is
given, however, the typical value is a good indication of device performance.
www.national.com 2