Electrical Characteristics (Continued)
LM185-2.5
LM185BX-2.5 LM385B-2.5
LM185BY-2.5 LM385BX-2.5 LM385-2.5 Units
LM285-2.5 LM385BY-2.5 (Limit)
Parameter Conditions Typ LM285BX-2.5
LM285BY-2.5
Tested Design Tested Design Tested Design
Limit Limit Limit Limit Limit Limit
(Note 5)
(Note 8)
(Note 6) (Note 5) (Note 6) (Note 5) (Note 6)
Reverse Breakdown T
A
=
25˚C, 2.5 2.462 2.462 2.425 V(Min)
Voltage 20 µA ≤ I
R
≤ 20 mA 2.538 2.538 2.575 V(Max)
Minimum Operating
Current
13 20 30 20 30 20 30 µA
(Max)
LM385M3-2.5 15 20
Reverse Breakdown
Voltage Change with
Current
20 µA ≤ I
R
≤ 1mA 1 1.5 2.0 2.5 2.0 2.5 mV
(Max)
1mA≤I
R
≤20 mA 10 20 20 25 20 25 mV
(Max)
Reverse Dynamic I
R
=
100 µA, 1 Ω
Impedance f=20 Hz
Wideband Noise (rms) I
R
=
100 µA, 120 µV
10 Hz ≤ f ≤ 10 kHz
Long Term Stability I
R
=
100 µA,
T=1000 Hr, 20 ppm
T
A
=
25˚C
±
0.1˚C
Average Temperature I
R
=
100 µA
Coefficient (Note 7) X Suffix 30 30 ppm/˚C
Y Suffix 50 50 ppm/˚C
All Others 150 150 150 ppm/˚C
(Max)
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is intended to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The
guaranteed specifications apply only for the test conditions listed.
Note 2: Refer to RETS185H-2.5 for military specifications.
Note 3: For elevated temperature operation, T
J MAX
is:
LM185 150˚C
LM285 125˚C
LM385 100˚C
Thermal Resistance TO-92 TO-46 SO-8 SOT-23
θ
ja
(Junction to Ambient) 180˚C/W (0.4" Leads) 440˚C/W 165˚C/W 283˚C/W
170˚C/W (0.125" Leads)
θ
jc
(Junction to Case) N/A 80˚C/W N/A N/A
Note 4: Parameters identified with boldface type apply at temperature extremes. All other numbers apply at T
A
=
T
J
=
25˚C.
Note 5: Guaranteed and 100%production tested.
Note 6: Guaranteed, but not 100%production tested. These limits are not used to calculate average outgoing quality levels.
Note 7: The average temperature coefficient is defined as the maximum deviation of reference voltage at all measured temperatures between the operating T
MAX
and T
MIN
, divided by T
MAX–TMIN
. The measured temperatures are −55˚C, −40˚C, 0˚C, 25˚C, 70˚C, 85˚C, 125˚C.
Note 8: A military RETS electrical specification available on request.
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 4