Absolute Maximum Ratings (Note 1)
Supply Voltage −0.2V to +6.0V
Voltage at OVERTEMP pin −0.2V to +6.0V
Voltage at OVERTEMP and
V
TEMP
pins −0.2V to (VDD + 0.5V)
TRIP TEST Input Voltage −0.2V to (VDD + 0.5V)
Output Current, any output pin ±7 mA
Input Current at any pin (Note 2) 5 mA
Storage Temperature −65°C to +150°C
Maximum Junction Temperature
T
J(MAX)
+155°C
ESD Susceptibility (Note 3) :
Human Body Model 2500V
Machine Model 250V
Charged Device Model 1000V
Soldering process must comply with National's
Reflow Temperature Profile specifications. Refer to
www.national.com/packaging. (Note 4)
Operating Ratings (Note 1)
Specified Temperature Range:
T
MIN
≤ TA ≤ T
MAX
LM26LV
−50°C ≤ TA ≤ +150°C
Supply Voltage Range (VDD)
+1.6 V to +5.5 V
Thermal Resistance (θJA) (Note 5)
LLP-6 (Package SDB06A) 152 °C/W
Accuracy Characteristics
Trip Point Accuracy
Parameter Conditions
Limits
(Note 7)
Units
(Limit)
Trip Point Accuracy (Note 8) 0 − 150°C
VDD = 5.0 V
±2.2 °C (max)
V
TEMP
Analog Temperature Sensor Output Accuracy
There are four gains corresponding to each of the four Temperature Trip Point Ranges. Gain 1 is the sensor gain used for Temperature Trip Point 0 - 69°C. Likewise Gain 2 is for Trip Points 70 - 109 °C; Gain 3 for 110 - 129 °C; and Gain 4 for 130 - 150 °C.
These limits do not include DC load regulation. These stated accuracy limits are with reference to the values in the LM26LV
Conversion Table.
Parameter Conditions
Limits
(Note 7)
Units
(Limit)
V
TEMP
Temperature
Accuracy
(Note 8)
Gain 1: for Trip Point
Range 0 - 69°C
TA = 20°C to 40°C VDD = 1.6 to 5.5 V
±1.8
°C (max)
TA = 0°C to 70°C VDD = 1.6 to 5.5 V
±2.0
TA = 0°C to 90°C VDD = 1.6 to 5.5 V
±2.1
TA = 0°C to 120°C VDD = 1.6 to 5.5 V
±2.2
TA = 0°C to 150°C VDD = 1.6 to 5.5 V
±2.3
TA = −50°C to 0°C VDD = 1.7 to 5.5 V
±1.7
Gain 2: for Trip Point
Range 70 - 109°C
TA = 20°C to 40°C VDD = 1.8 to 5.5 V
±1.8
°C (max)
TA = 0°C to 70°C VDD = 1.9 to 5.5 V
±2.0
TA = 0°C to 90°C VDD = 1.9 to 5.5 V
±2.1
TA = 0°C to 120°C VDD = 1.9 to 5.5 V
±2.2
TA = 0°C to 150°C VDD = 1.9 to 5.5 V
±2.3
TA = −50°C to 0°C VDD = 2.3 to 5.5 V
±1.7
Gain 3: for Trip Point
Range 110 - 129°C
TA = 20°C to 40°C VDD = 2.3 to 5.5 V
±1.8
°C (max)
TA = 0°C to 70°C VDD = 2.5 to 5.5 V
±2.0
TA = 0°C to 90°C VDD = 2.5 to 5.5 V
±2.1
TA = 0°C to 120°C VDD = 2.5 to 5.5 V
±2.2
TA = 0°C to 150°C VDD = 2.5 to 5.5 V
±2.3
TA = −50°C to 0°C VDD = 3.0 to 5.5 V
±1.7
Gain 4: for Trip Point
Range 130 - 150°C
TA = 20°C to 40°C VDD = 2.7 to 5.5 V
±1.8
°C (max)
TA = 0°C to 70°C VDD = 3.0 to 5.5 V
±2.0
TA = 0°C to 90°C VDD = 3.0 to 5.5 V
±2.1
TA = 0°C to 120°C VDD = 3.0 to 5.5 V
±2.2
TA = 0°C to 150°C VDD = 3.0 to 5.5 V
±2.3
TA = −50°C to 0°C VDD = 3.6 to 5.5 V
±1.7
www.national.com 4
LM26LV