Switching Characteristics
V
CC+
=
5V, V
CC−
=
−5V, T
A
=
25˚C
Symbol Parameter Conditions Min Typ Max Units
t
PLH(D)
Propagation Delay Time, Low to
High Level, from Differential Inputs
A and B to Output
R
L
=
390Ω,C
L
=
50 pF,
(Note 4)
17 25 ns
19 25 ns
t
PHL(D)
Propagation Delay Time, High to
Low Level, from Differential Inputs
A and B to Output
R
L
=
390Ω,C
L
=
50 pF,
(Note 4)
17 25 ns
19 25 ns
t
PLH(S)
Propagation Delay Time, Low to
High Level, from Strobe Input G or
S to Output
R
L
=
390Ω,C
L
=
50 pF 10 15 ns
13 20 ns
t
PHL(S)
Propagation Delay Time, High to
Low Level, from Strobe Input G or
S to Output
R
L
=
390Ω,C
L
=
50 pF 8 15 ns
13 20 ns
Switching Characteristics
V
CC+
=
5V, V
CC−
=
−5V, T
A
=
25˚C
Symbol Parameter Conditions Min Typ Max Units
t
PLH(D)
Propagation Delay Time, Low-to- R
L
=
470Ω,C
L
=
15 pF, (Note 6)
High Level, from Differential 35 ns
Inputs A and B to Output
t
PHL(D)
Propagation Delay Time, High-to- R
L
=
470Ω,C
L
=
15 pF, (Note 6)
Low Level, from Differential 20 ns
Inputs A and B to Output
t
PLH(S)
Propagation Delay Time, Low-to- R
L
=
470Ω,C
L
=
15 pF
High Level, from Strobe Input G 17 ns
or S to Output
t
PHL(S)
Propagation Delay Time, High-to- R
L
=
470Ω,C
L
=
15 pF
Low Level, from Strobe Input G 17 ns
or S to Output
Note 1: “Absolute MaximumRatings” are those valuesbeyond which the safety of the device cannot beguaranteed. Except for “OperatingTemperature Range” they
are not meant to imply that the devices should be operated at these limits. The table of “Electrical Characteristics” provides conditions for actual device operation.
Note 2: Unless otherwise specified min/max limits apply across the 0˚C to +70˚C range for the DS75107. All typical values are for T
A
=
25˚C and V
CC
=
5V.
Note 3: All currents into device pins shown as positive, out of device pins as negative, all voltages referenced to ground unless otherwise noted. All values shown
as max or min on absolute value basis.
Note 4: Differential input is +100 mV to −100 mV pulse. Delays read from 0 mV on input to 1.5V on output.
Note 5: Only one output at a time should be shorted.
Note 6: Differential input is +10 mV to −30 mV pulse. Delays read from 0 mV on input to 1.5V on output.
Voltage Waveforms
DS009446-12
www.national.com3