Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage 8V
Input Voltage 5.5V
Storage Temperature −65˚C to +150˚C
Maximum Power Dissipation (Note 1) at 25˚C
Molded DIP Package 1476 mW
SO Package 1051 mW
Lead Temperature
(Soldering, 4 seconds) 260˚C
Operating Conditions
Min Max Units
Supply Voltage, V
CC
DS3487 4.75 5.25 V
Temperature (T
A
)
DS3487 0 +70 ˚C
Note 1: Derate DIP molded package 11.9 mW/˚C above 25˚C. Derate SO
package 8.41 mW/˚C above 25˚C.
Electrical Characteristics (Notes 3, 4, 5, 6)
Symbol Parameter Conditions Min Typ Max Units
V
IL
Input Low Voltage 0.8 V
V
IH
Input High Voltage 2.0 V
I
IL
Input Low Current V
IL
=
0.5V −200 µA
I
IH
Input High Current V
IH
=
2.7V 50 µA
V
IH
=
5.5V 100 µA
V
CL
Input Clamp Voltage I
CL
=
−18 mA −1.5 V
V
OL
Output Low Voltage I
OL
=
48 mA 0.5 V
V
OH
Output High Voltage I
OH
=
−20 mA 2.5 V
I
OS
Output Short-Circuit Current −40 −140 mA
I
OZ
Output Leakage Current
(TRI-STATE)
V
O
=
0.5V −100 µA
V
O
=
5.5V 100 µA
I
OFF
Output Leakage Current Power OFF V
CC
=
0V V
O
=
6V 100 µA
V
O
=
−0.25V −100 µA
|V
OS
–V
OS
|
Difference in Output Offset Voltage 0.4 V
V
T
Differential Output Voltage 2.0 V
|V
T
|– VT| Difference in Differential Output
Voltage
0.4 V
I
CC
Power Supply Current Active 50 80 mA
TRI-STATE
®
35 60 mA
Switching Characteristics
V
CC
=
5V, T
A
=
25˚C
Symbol Parameter Conditions Min Typ Max Units
t
PHL
Input to Output 10 15 ns
t
PLH
Input to Output 10 15 ns
t
THL
Differential Fall Time 10 15 ns
t
TLH
Differential Rise Time 10 15 ns
t
PHZ
Enable to Output R
L
=
200Ω,C
L
=
50 pF 17 25 ns
t
PLZ
Enable to Output R
L
=
200Ω,C
L
=
50 pF 15 25 ns
t
PZH
Enable to Output R
L
=
∞
,C
L
=
50 pF, S1 Open 11 25 ns
t
PZL
Enable to Output R
L
=
200Ω,C
L
=
50 pF, S2 Open 15 25 ns
Note 2: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The table of “Electrical Characteristics” provides conditions for actual device operation.
Note 3: Unless otherwise specified min/max limits apply across the 0˚C to +70˚C range for the DS3487. All typicals are given for V
CC
=
5V and T
A
=
25˚C.
Note 4: All currents into device pins are positive, all currents out of device pins as negative. All voltages are referenced to ground unless otherwise specified.
Note 5: Only one output at a time should be shorted.
Note 6: Symbols and definitions correspond to EIA RS-422, where applicable.
www.national.com 2