NSC 54F163ALMQB, 54F163ADMQB, 54F163ADM, 54F163ADC Datasheet

TL/F/9486
54F/74F161A
#
54F/74F163A Synchronous Presettable Binary Counter
November 1994
54F/74F161A#54F/74F163A Synchronous Presettable Binary Counter
The ’F161A and ’F163A are high-speed synchronous modu­lo-16 binary counters. They are synchronously presettable for application in programmable dividers and have two types of Count Enable inputs plus a Terminal Count output for versatility in forming synchronous multi-stage counters. The ’F161A has an asynchronous Master-Reset input that over­rides all other inputs and forces the outputs LOW. The ’F163A has a Synchronous Reset input that overrides counting and parallel loading and allows the outputs to be simultaneously reset on the rising edge of the clock. The ’F161A and ’F163A are high-speed versions of the ’F161 and ’F163.
Features
Y
Synchronous counting and loading
Y
High-speed synchronous expansion
Y
Typical count frequency of 120 MHz
Y
Guaranteed 4000V minimum ESD protection
Commercial Military
Package
Package Description
Number
74F161APC N16E 16-Lead (0.300×Wide) Molded Dual-In-Line
54F161ADM (Note 2) J16A 16-Lead Ceramic Dual-In-Line
74F161ASC (Note 1) M16A 16-Lead (0.150×Wide) Molded Small Outline, JEDEC
74F161ASJ (Note 1) M16D 16-Lead (0.300×Wide) Molded Small Outline, EIAJ
54F161AFM (Note 2) W16A 16-Lead Cerpack
54F161ALM (Note 2) E20A 20-Lead Ceramic Leadless Chip Carrier, Type C
74F163APC N16E 16-Lead (0.300×Wide) Molded Dual-In-Line
54F163ADM (Note 2) J16A 16-Lead Ceramic Dual-In-Line
74F163ASC (Note 1) M16A 16-Lead (0.150×Wide) Molded Small Outline, JEDEC
74F163ASJ (Note 1) M16D 16-Lead (0.300×Wide) Molded Small Outline, EIAJ
54F163AFM (Note 2) W16A 16-Lead Cerpack
54F163ALM (Note 2) E20A 20-Lead Ceramic Leadless Chip Carrier, Type C
Note 1: Devices also available in 13×reel. Use suffixeSCX and SJX. Note 2: Military grade device with environmental and burn-in processing. Use suffix
e
DMQB, FMQB and LMQB.
Connection Diagrams
Pin Assignment
for DIP, SOIC and Flatpak
’F161A
TL/F/9486– 1
Pin Assignment
for LCC
’F161A
TL/F/9486– 2
Pin Assignment
for DIP, SOIC and Flatpak
’F163A
TL/F/9486– 7
Pin Assignment
for LCC
’F163A
TL/F/9486– 8
TRI-STATEÉis a registered trademark of National Semiconductor Corporation.
C
1995 National Semiconductor Corporation RRD-B30M75/Printed in U. S. A.
Logic Symbols
’F161A
TL/F/9486– 3
IEEE/IEC
’F161A
TL/F/9486– 6
’F163A
TL/F/9486– 9
IEEE/IEC
’F163A
TL/F/9486– 10
Unit Loading/Fan Out
54F/74F
Pin Names Description
U.L. Input I
IH/IIL
HIGH/LOW Output IOH/I
OL
CEP Count Enable Parallel Input 1.0/1.0 20 mA/b0.6 mA CET Count Enable Trickle Input 1.0/2.0 20 mA/
b
1.2 mA
CP Clock Pulse Input (Active Rising Edge) 1.0/1.0 20 mA/
b
0.6 mA MR (’F161A) Asynchronous Master Reset Input (Active LOW) 1.0/1.0 20 mA/b0.6 mA SR
(’F163A) Synchronous Reset Input (Active LOW) 1.0/2.0 20 mA/b1.2 mA
P0–P
3
Parallel Data Inputs 1.0/1.0 20 mA/b0.6 mA
PE
Parallel Enable Input (Active LOW) 1.0/2.0 20 mA/b1.2 mA
Q
0–Q3
Flip-Flop Outputs 50/33.3
b
1 mA/20 mA
TC Terminal Count Output 50/33.3
b
1 mA/20 mA
2
Functional Description
The ’F161A and ’F163A count in modulo-16 binary se­quence. From state 15 (HHHH) they increment to state 0 (LLLL). The clock inputs of all flip-flops are driven in parallel through a clock buffer. Thus all changes of the Q outputs (except due to Master Reset of the ’F161A) occur as a re­sult of, and synchronous with, the LOW-to-HIGH transition of the CP input signal. The circuits have four fundamental modes of operation, in order of precedence: asynchronous reset (’F161A), synchronous reset (’F163A), parallel load, count-up and hold. Five control inputsÐMaster Reset (MR
,
’F161A), Synchronous Reset (SR
, ’F163A), Parallel Enable
(PE
), Count Enable Parallel (CEP) and Count Enable Trickle (CET)Ðdetermine the mode of operation, as shown in the Mode Select Table. A LOW signal on MR
overrides all other inputs and asynchronously forces all outputs LOW. A LOW signal on SR
overrides counting and parallel loading and allows all outputs to go LOW on the next rising edge of CP. A LOW signal on PE
overrides counting and allows informa-
tion on the Parallel Data (P
n
) inputs to be loaded into the
flip-flops on the next rising edge of CP. With PE
and MR (’F161A) or SR (’F163A) HIGH, CEP and CET permit count­ing when both are HIGH. Conversely, a LOW signal on ei­ther CEP or CET inhibits counting.
The ’F161A and ’F163A use D-type edge triggered flip-flops and changing the SR
,PE, CEP and CET inputs when the CP is in either state does not cause errors, provided that the recommended setup and hold times, with respect to the ris­ing edge of CP, are observed.
The Terminal Count (TC) output is HIGH when CET is HIGH and the counter is in state 15. To implement synchronous multi-stage counters, the TC outputs can be used with the CEP and CET inputs in two different ways. Please refer to the ’F568 data sheet. The TC output is subject to decoding spikes due to internal race conditions and is therefore not recommended for use as a clock or asynchronous reset for flip-flops, counters or registers.
Logic Equations: Count Enable
e
CEP#CET#PE
TCeQ
0
#
Q
1
#
Q
2
#
Q
3
#
CET
Mode Select Table
*SR PE CET CEP
Action on the Rising
Clock Edge (L)
L X X X Reset (Clear)
H L X X Load (P
n
x
Qn) H H H H Count (Increment) H H L X No Change (Hold) H H X L No Change (Hold)
*For ’F163A only
H
e
HIGH Voltage Level
L
e
LOW Voltage Level
X
e
Immaterial
State Diagram
TL/F/9486– 5
3
Loading...