For lead acid batteries
Digital Hydrometer
DH-10C
Cat.No.3446
DH-10F
Cat.No.3447
Specific gravity of
sulfuric lead-acid
battery fluid
No more cumbersome cleaning. Lightweight, compact,
and battery-operated for maximum portability.
Single-handed operation from measurement
to cleaning, without touching any liquid!
utomatic
emperature
ompensation
Measures specific
gravity and temperature
simultaneously.
Digital Hydrometer
sales@novatech-usa.com
www.novatech-usa.com
Tel: (866) 433-6682 Fax: (866) 433-6684
Tel: (281) 359-8538 Fax: (281) 359-0084
DH-10C DH-10F
Cat.No.3446
For determining the charge level of lead acid batteries commonly used as industrial battery banks.
How to Use
Cat.No.3447
Squeeze,
Air Out
Squeeze the
pump to create
a vacuum.
Pump
Sample
chamber
(prism)
Squeeze
& Release,
Easy Cleaning
Release,
Sample In
Operation
Release the
pump to draw
the sample in.
Easy
Press the START key,
and measurement is
complete in 3 seconds.
Face Panel
(ex : DH-10C)
Increased efficiency over a conventional
glass hydrometer and thermometer
A service tech visits 30 power systems a month. Using a
standard hydrometer, it takes him 20 minutes per
system to do the job. The DH-10 Digital Hydrometer
reduces the service time to 2 minutes per system.
His labor costs $40 /hour.
A standard glass hydrometer :
20 minutes × 30 sites = 10 hours, $400 worth of labor every month
DH-10 Digital Hydrometer:
2 minutes × 30 sites = 1 hour, $40 worth of labor every month
The benefits are 108 hours = $4,320
of savings every year, per service tech.
Office : 11811 NE 1st Street Suite 101 Bellevue, WA 98005 U.S.A.
TEL : 1-425-637-2107 FAX : 1-425-637-2110
customerservice@atago-usa.com
TOLL FREE : 1-877-ATAGO-US ( 1-877-282-4687 )
Headquarters: The Front Tower Shiba Koen, 23rd Floor
2-6-3 Shiba-koen, Minato-ku, Tokyo 105-0011, Japan
TEL : 81-3-3431-1943 FAX : 81-3-3431-1945
overseas@atago.net http : //www.atago.net/
* Specifications and appearance are subject to change without notice.
1309K Printed in Japan
USV.03
SpecificationsExample of Time and Cost Savings
DH-10C
Measurement range Sulfuric acid specific gravity 1.000 to 1.3000
Resolution 0.001
Accuracy
Sample
chamber temperature
Ambient
temperature range
Power supply DC9V (006P Battery)
International
Protection class
Dimensions and weight 70 × 40 × 210 mm (Main unit only), 235 g
±0.002 (10 to 30°C)
±0.003 (0 to 10 or 30 to 40°C)
±0.005 (-10 to 0 or 40 to 50°C)
-10 to 50°C
5 to 40°C
All ATAGO refractometers are designed and manufactured in Japan.
Cat. No. 3446
ATAGO products comply with HACCP,GMP,
and GLP system standards.
DH-10F
±0.002 (50 to 86°F)
±0.003 (32 to 50 or 86 to 104°F)
±0.005 (14 to 32 or 104 to 122°F)
14 to 122°F
41 to 104°F
IP64
Cat. No. 3447