ICUMSA compliant
Automatic Temperature Compensation
Automatic Temperature Compensation
Function for International Sugar Scale
Function for International Sugar Scale
Finally, a multifunctional fully automatic polarimeter
Finally, a multifunctional fully automatic polarimeter
at a reasonable price!
at a reasonable price!
Automatic
Polarimeter
Cat.No.5291
Angle of Rotation
International Sugar Scale
(without temperature compensation)
International Sugar Scale
(with Automatic Temperature Compensation)
Specific Optical Rotation
Concentration
Purity

Automatic
Polarimeter
Features
Features
Easy To Use: Simply place an observation tube
in the sample chamber of the AP-300 and press
START key
The minimum angle of rotation is 0.01°, the
minimum International Sugar Scale is 0.01°Z
Automatic Temperature Compensation Function
for International Sugar Scale with a range
between 18°C and 30°C
Conforms with ICUMSA standards
Built in memory stores the 30 most recent
measurement readings
Out-of-range measurements are indicated
instantly by graphic display
The AP-300 offers ease of use with a very
competitive price
Compact and space saving
NEW
Average Measurement Value is Displayed!
NEW
Password Function as necessary for ISO
Standard!
Application
Application
Measures the specific optical rotation of
medical agents
Measures the concentration of optically active
substances found in fragrance materials or
chemical compositions
Measures the international sugar scale and the
purity of sugar
Identifies the attributes of inverted sugar, etc.
Measures the specific optical rotation or the
concentration of optically active substances
Example of angle of rotation display
Example of angle of rotation display
Mode
Name of
scale
Measurement
wavelength
( )
Length of
sample tube
(L)
MAY.12, 2011 07:10
MAY.12, 2011 07:10
Date and time
Measurement
reading
Measurement
temperature
(TEMP)
Type of
sample tube
(TUBE)
Operation
keys
Explanation of measurements display
Angle of rotation
The angle of rotation is the basic numeric value measured by
polarimeters, and changes depending on the concentration of the
solution, the length of the observation tube, temperature, and/or the
measurement wavelength. It is symbolized by "
International Sugar Scale
The International Sugar Scale is indicated in "°Z."
The measurement value of 26g of sucrose in 100ml of sucrose solution
in a 200mm observation tube is 100°Z. This measurement value is
commonly used in the sugar manufacturing industry, and is usually
temperature-compensated to the reference temperature of 20°C (68°F).
The AP-300 can display the measurement value with or without temperature
compensation (Automatic Temperature Compensation, "ATC").
Specific Rotation
The Specific Rotation is a numeric value unique to each substance. By
definition, the specific rotation value is equivalent to the angle of
rotation obtained by a measuring a solution of 100% concentration in a
100mm observation tube (although such a measurement is actually not
practical).
Specific rotation is symbolized by "[α]" and indicated in "
Concentration
The Concentration is the density of a liquid solution made by dissolving
an optically active substance in water or alcohol. It is indicated in
"g/100ml."
Purity
The Purity is the proportion of sucrose compared to the soluble solid
content in a sample. It is indicated in "%." To measure the purity, input
the Brix value of the sample (which can be obtained by using an ATAGO
refractometer) into the AP-300 before taking a measurement.
α" and indicated in "
°
."
°
."

Jacketed flow tube
Jacketed flow tube
with funnel
Special Packages
ATAGO has prepared 4different AP-300 packages.
Observation tubes
RE-72001 : Observation tube 100mm long OT-100(A)
RE-72002 : Observation tube 200mm long OT-200(A)
RE-72036 : Jacketed flow tube 50mm
RE-72034 : Jacketed flow tube 100mm
RE-72035 : Jacketed flow tube 200mm
RE-72033 : Jacketed flow tube with funnel 100mm
RE-72032 : Jacketed flow tube with funnel 200mm
RE-72037 : Unjacketed flow tube with funnel 100mm
RE-72038 : Unjacketed flow tube with funnel 200mm
RE-72042 : Unjacketed small volume observation
tube 10mm long
RE-76015 : Sample chamber cover for Flow Cell
(Cover only)
RE-76016 : Inner lid for 100mm tube
RE-76017 : Inner lid for 200mm tube
RE-76018 : Inner lid for 50mm tube
* To use the flow tubes, the sample chamber RE-76015
* To use the flow tubes, the sample chamber RE-76015
and a inner lid matching the size of the tube will be
and a inner lid matching the size of the tube will be
necessary to be purchased.
necessary to be purchased.
Recommended for sugar industry
Type A
Temperature Control
Cat.No.5296
● AP-300 (including accessories)
● Jacketed flow tube with funnel and
● temperature sensor for jacket (200mm-approximate volume 15ml)
● Inner Lid (For Tube 200mm)
* Circulating Constant Temperature Bath 60-C3
(Cat.No.1921) sold separately.
Type B
No Temperature Control
Cat.No.5297
● AP-300 (including accessories)
● Unjacketed flow tube with funnel (200mm-approximate volume 15ml)
● Inner Lid (For Tube 200mm)
Recommended for pharmaceutical industry
Type C
Temperature Control
Cat.No.5294
● AP-300 (including accessories)
● Jacketed flow tube and temperature sensor for jacket
(100mm-approximate volume 10ml)
● Quartz Control Plate (8°, 17°, or 34°)
● Digital printer DP-AD
● Printer paper for DP-AD
● Ribbon cassette for DP-AD
● Circulating Constant Temperature Bath 60-C3 (Cat.No.1921)
Type D
No Temperature Control
Cat.No.5295
● AP-300 (including accessories)
● Quartz Control Plate (8°, 17°, or 34°)
● Digital printer DP-AD
● Printer paper for DP-AD
● Ribbon cassette for DP-AD
Options other than above mentioned 4 types are available.
Contact your nearest ATAGO representative for details.
ICUMSA compliant
Automatic Temperature
Compensation Function for
International Sugar Scale
Type A

AP-300 Specifications
sales@novatech-usa.com
www.novatech-usa.com
Tel: (866) 433-6682 Fax: (866) 433-6684
Tel: (281) 359-8538 Fax: (281) 359-0084
AP-300 Specifications
Measurement
scales
Measurement
readings
Measurement
readings
Measurement
indication
Measurement
accuracy
Temperature compensation
range for International Sugar
Scale
Length of
observation tube
Option
Option
Angle of Rotation, International Sugar Scale (without
temperature compensation)
(with Automatic Temperature Compensation)
Angle of Rotation, International Sugar Scale (without
temperature compensation)
(with Automatic Temperature Compensation), Specific
Optical Rotation, Concentration, and Purity.
Angle of Rotation : –89.99 to + 89.99°
International Sugar Scale : –130.00 to + 130.00°Z
Angle of Rotation : 0.01°
International Sugar Scale : 0.01°Z
Angle of Rotation :
Displayed value ±0.01°(–35.00 to +35.00°)
Relative precision ±0.2% (–35.01 to –89.99°, +35.01 to + 89.99°)
International Sugar Scale :
Displayed value ±0.03°Z (–101.00 to +101.00°Z)
Relative precision ±0.2%
(–130.00 to –101.01°Z, +101.01 to +130.00°Z)
( Checked by reading a standard Quartz Plate )
18.0 to 30.0°C
Up to 200mm
Digital printer DP-63
Cat.No.3118
,
International Sugar Scale
, International Sugar Scale
Temperature
accuracy
History function
Display panel
Graphic display
Additional
Features
Output
Light source
Accessories
Power supply
Power
consumption
Dimensions and
weight
±0.5°C
History function stores the 30 previous measurement
values for reference, printing or exporting to a computer.
Backlit Color LCD
Graphic display indicating the conformity of measurement
values for measurements with limit settings.
(1) Average Measurement Value
(2) Password Function
(1) Digital Printer DP-63 or DP-AD (optional).
(2) RS-232C input/output ports for connecting to a
computer system.
Halogen lamp
Observation tubes (100mm [ 5m ], 200mm [10m ])
AC100V to 240V, 50/60Hz
65VA
48.5×28.5×17.5cm, 14.4kg (main unit only)
Digital Printer DP-AD
Cat.No.3123
Input method
Type of printer
Printing data fields
RS-232C
Thermal dot matrix printer
Angle of rotation, International
Sugar Scale, Specific optical rotation, Concentration, Purity,
Length of sample tube, Measurement temperature, Day, Month,
Year and Time
Power supply
Power consumption
Dimensions and weight
AC adapter
(Input voltage : AC100 to 240V)
13VA
17×16×7cm,
Dimensions and weight
580g (main unit only)
Circulating constant temperature
Quartz control plates
RE-72043 :
Quartz Control Plate 8°(25°Z)
RE-72044 :
Quartz Control Plate 17°(50°Z)
RE-72045 :
Quartz Control Plate 34°(100°Z)
EXPLANATION OF ICONS
• Can be connected to a printer
• Sortie imprimante
• Verbindung mit Personalcomputer
• Collegabile a stampante esterna
• Conexión para impresora
•
RE-72048 :
RE-72049 :
RE-72050 :
Icons, for functions, specifications and scales have been added to this catalog
Quartz Control Plate
Quartz Control Plate
Quartz Control Plate
• RS-232C Interface
• Interface RS232C pour PC
• Interface RS232C
• Interfaccia RS232C
• Interface RS232C
• RS232C
–
8° (–25°Z)
–
17° (–50°Z)
–
34° (–100°Z)
• Automatic Temperature Compensation
• Compensation automatique de
• Automatische Temperaturkompensation
• Compensazione automatica della temperatura
• Compensación de automática de temperatura
•
Bath 60-C4
Temperature setting range
Dimensions and weight
All ATAGO polarimeters are designed and manufactured in Japan.
Input method
Type of Printer
Printing data fields
Power supply
Power consumption
Tank capacity
Constant-temperature
accuracy
Flow rate
Power supply
Power consumption
RS-232C
Impact dot printing
on rolled plain paper (not thermal)
Angle of rotation, International Sugar Scale,
Specific optical rotation, Concentration, Purity,
length of sample tube, Measurement temperature, Day, Month, Year and Time
AC adapter
(Input voltage : AC100 to 240V)
7VA
11×18×9cm, 470g (main unit only)
Cat.No.1922
0.5
10 to 60°C (water)
±0.2°C, PID control method using a thermo-
module
4 / min.
AC100 to 240V, 50 / 60Hz
430VA
38×24×27cm, 11.0kg (main unit only)
• Digital display
• Affichage numérique
• Digital Anzeige
• Display digitale
• Pantalla digital
•
• AC outlet(AC100 to 240V)
• Alimentation secteur(CA 100 à 240 V)
• AC Ausgang (AC 100 bis 240V)
• Uscita AC( AC 100 240V )
• Conexión a 240V CA
• AC (AC 100 240V)
ATAGO products comply with HACCP,
GMP, and GLP system standards.
Headquarters: The Front Tower Shiba Koen, 23rd Floor
2-6-3 Shiba-koen, Minato-ku, Tokyo 105-0011, Japan
TEL : 81-3-3431-1943 FAX : 81-3-3431-1945
overseas@atago.net http : //www.atago.net/
TEL : 1-425-637-2107 customerservice@atago-usa.com
TEL : 91-22-2833-8038 / 8076 customerservice@atago-india.com
TEL : 662-982-8718-9 customerservice@atago-thailand.com
TEL : 55 16 3916-6000 customerservice@atago-brasil.com
TEL : 39 2 36557267 customerservice@atago-italia.com
TEL : 86 20-38106065 info@atago-china.com
ISO9001
REGISTERED
* Specifications and appearance are subject to change without notice.
12100000PP Printed in Japan
V.04