North Star M165923V.1 User Manual

M165923V.1
ITEM NUMBER: 165923
TM
Owner’s Manual
SERIAL NUMBER: _____________
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Gasoline Generator
10,500 Watt Continuous (13,000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back­up connection to a building’s power supply (via a professionally installed UL-approved transfer switch).
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up, operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
WARNING
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or semi-enclosed spaces, including homes, basements, garages, sheds , boxes , RVs, boats or pick-up truck beds. These spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildin gs (bat t er y -o perat ed , or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7’ from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station – use approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator to
your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
Hazard Signal Word Definitions
2
Table of Contents
Hazard Signal Word Definitions .................................................................................................2
About Your Generator .................................................................................................................4
Specifications .................................................................................................................................6
Safety Label Locations..................................................................................................................7
Machine Component Identification.............................................................................................8
Power Load Planning & Management........................................................................................10
Installation / Initial Set-Up:
1. Unpacking & Delivery Inspection..........................................................................................12
2. Planning the Power Load........................................................................................................12
3. Set-up as a PORTABLE or BUILDING BACK-UP Power Source ......................................13
4. Selecting a Suitable Site.........................................................................................................16
5. Grounding the Generator........................................................................................................18
6. Battery Installation .................................................................................................................19
Operation:
1. General Safety Rules for Operation .......................................................................................20
2. Preparing for Operation..........................................................................................................23
3. Starting the Engine.................................................................................................................26
4. Checking Generator Output....................................................................................................27
5. Connecting Loads...................................................................................................................28
6. Stopping the Engine ...............................................................................................................28
7. Storage & Exercise.................................................................................................................29
Maintenance & Repair..................................................................................................................31
Troubleshooting.............................................................................................................................33
Summary of Important Safety Information for Operation.......................................................34
Generator Exploded View............................................................................................................38
Wiring Diagram.............................................................................................................................40
Generator Head Exploded View.................................................................................................42
3
About Your Generator
This engine-driven, portable generator is designed to provide up to 13,000 Watts of electrical power (10,500 watts continuous, 13,000 watts surge).
It can supply power:
1. As a portable power source. You can plug appliances directly into the generator’s
2. As a back-up, standby power source for a building. A licensed electrician can connect
You must select a generator adequately sized for your power needs. You need to determine the power needs of all the appliances/tools you wish to power at the same time and choose a generator rated to provide at least that power level. See the “Power Load Planning & Management” section of this manual to determine your specific power load requirements and then compare them to this generator’s rated capacity. You must not overload the generator. Overloading will cause damage to the generator and attached electrical devices, and may also result in fire.
Be sure to read about site selection and grounding requirements for running this generator. More detailed information can be found in the “Installation & Initial Set-up, Steps
5 & 6” of this manual. This generator is too heavy for one person to lift without mechanical assistance. An
optional wheel kit is available from NorthStar and is recommended if you will be moving the generator unassisted. Other optional accessories available from NorthStar include a vi nyl cover for storage, UL-approved transfer switches, and extension cords.
Contact NorthStar Product Support at 1-800-270-0810 with questions about optional
Thank you for purchasing your NorthStar portable generator!
About Your Generator
electrical outlets.
the generator to your building’s electrical system via the installation of an UL-approved transfer switch. (See the “Installation & Initial Set-up” section of this manual to learn more about specific requirements and precautions relating to wiring the generator to your building’s electrical system.)
accessories or to order.
Read this Manual
Improper use or maintenance of this generator can result in serious injury or death from carbon monoxide poisoning, electric shock/electrocution, fire/explosion, or burns.
Read this manual completely before using the generator and follow all instructions and safety rules.
You must follow all instructions and safety precautions presented throughout this manual. A summary of important safety information can be found at the end of the manual. Keep this manual for reference and review.
Proper preparation, operation, and maintenance will result in operator safety, as well as best performance and long life of the generator. For detailed engine operation and maintenance information, always refer to the engine Owner’s Manual furnished with the generator.
4
WARNING
About Your Generator (cont’d)
NorthStar is constantly improving its products. The specifications outlined herein are subject to change without prior notice or obligation. The purchaser and/or user shall assume liability for any modification and/or alterations of this equipment from original design and manufacture.
Before using, the user shall determine the suitability of this product for its intended use and assumes liability therein.
Contact NorthStar Product Support at 1-800-270-0810 for any questions about the
appropriate use of this generator.
Warranty Registration
Please fill out and submit the warranty registration card so that we have your contact information for any future product literature or replacement parts you may need.
ATTENTION:
All Rental Companies and Private Owners who loan this
All persons to whom you rent/loan this generator must have access to and read this manual. Keep this owner’s manual with the generator at all times and advise all persons who will operate the machine to read it. You must also provide personal instruction on how to safely operate the generator and remain available to answer any questions a renter/borrower might have.
equipment to others!
5
Specifications – Item #165923
SPECIFICATIONS
Item Number 165923 Maximum Output 13000 Watts (W) Continuous Output 10500 Watts (W) Voltage 120/240 Volt (V) Phase Single phase (4-wire) Frequency 56.5-63.3 Hertz (Hz) Power Factor 1.0 p.f. Total Harmonic Distortion less than 5% Engine 20 HP Honda Engine Speed 3390 - 3798 RPM Fuel Type Unleaded gasoline Fuel Capacity 10 gallons (38.0 L) Oil Capacity See Honda Manual Starting Method Electric start 120V Receptacles 2 - 20 Amp (A) duplex (NEMA 5-20R)
30 Amp (A) locking device (NEMA L5-30R)
120/240V Receptacles 30 Amp (A) locking device (NEMA L14-30R)
50 Amp (A) straight blade (NEMA 14-50R)
Circuit Breakers 50 Amp (A) thermal magnetic
30 Amp (A) thermal magnetic
30 Amp (A) thermal, push to reset
2 - 20 Amp (A) thermal, push to reset
Battery (not included) See Honda Engine Manual for Battery Rating
Battery Size: Group U1-7
Dimensions
Length 41.11” (104.4 cm) Width 24.25” (61.6 cm) Height 26.25” (66.7 cm) Dry Weight 340 lb. (155 kg) Gross Weight 410 lb. (186 kg)
6
Safety Label Locations – Item #165923V.1
DANGER
Using a generator indoors CAN KILL YOU IN
Commercial-grade electric start engine
Extend run 10 gallon fuel tank
Maintenance-free brushless alternator design
Smooth running focus mount is olation system
BATTERIES:
1) contain caustic acid, 2) emit explosive gases, 3) can cause electric shock ALWAYS use eye protection. Caustic acid and explosive gases can cause blindness or severe burns. NO smoking, sparks, or flames. NEVER touch both battery terminals at the same time with your hand or any non-insulated tools. FLUSH immediately with water if battery acid contacts eyes, skin, or clothing. CONNECT cables in correct sequence: FIRST RED to POSITIVE terminal, then BLACK to NEGATIVE terminal. When disconnecting, DISCONNECT BLACK cable first, then RED. NEVER charge a visibly damaged or frozen battery. ALWAYS read and follow charger instructions.
Always make sure safety labels are in place and in good condition. If a safety label is missing or not legible, order new labels or unsafe operation could result.
To order replacement safety labels, call NorthStar Product Support at 1-800-270-0810.
IF GENERATOR IS TO BE STORED LONGER THAN 2 MONTHS,
charge battery with a trickle charger that is rated for 3 amps maximum.
©2007 NT+E 1-800-270-0810
WARNING - BATTERY HAZARDS
ATTENTION
A changed battery ensures reliable engine starting.
MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage. EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Avoid other generator hazards.
READ MANUAL BEFORE USE.
PN 779396
On-Product Warning Labels
Part numbers Description
779396 Battery Warning 779399 NorthStar Warning
7
Machine Component Identification - Item #165923V.1
Figure 1 (Ref. 1-10)
Ref. Description Ref. Description
1 Air Cleaner 11 10.0 Gallon Gas Tank 2 Optional Wheel Kit (#165919) 12 Engine Key Switch 3 Circuit Breakers 13 Choke Lever 4 120/240V, 50A Receptacle 14 Muffler 5 120/240V, 30A
Locking Receptacle 6 120V, 30A Locking Receptacle 16 Battery Box 7 120V, 20A Duplex Receptacle 17 Fuel Line Valve 8 Oil Drain Plug 18 Generator Head 9 Vibration Isolation Mount 19 Gas Cap with Gauge
10 Oil Filler Cap
Figure 2 (Ref. 11-19)
15 Oil Filter
8
Machine Component Identification - Item #165923V.1
REFERENCE GUIDE
Reference 1 – Air Cleaner Reference 2 – Optional Wheel Kit Reference 3 – Circuit Breakers
Reference 4 – 120/240V, 50A Receptacle
Reference 5 – 120/240V, 30A Locking Device Receptacle
Reference 6 – 120V, 30A Locking Device Receptacle
Reference 7 – 120V, 20A Duplex Receptacle
Reference 8 – Oil Drain Plug Reference 9 – Vibration Isolation
Mount
Reference 10 – Oil Filler Cap Reference 11 - 10.0 Gallon Gas Tank
Reference 12 – Engine Key Switch
Reference 13 - Choke Lever Reference 14 – Muffler Reference 15 – Oil Filter
Reference 16 – Battery Box
Reference 17 – Fuel Line Valve
Reference 18 – Generator Head Reference 19 – Gas Cap with Gauge
Refer to your Honda engine manual for air cleaner care. Optional heavy duty wheel kit (Item # 165919). This portable single phase generator has 1 - 50 amp (A) thermal magnetic 2 pole breaker, 1 - 30 amp (A) thermal magnetic 2 pole breaker 1 - 30 amp (A) push to reset circuit breaker, and 2 - 20 amp (A) push to reset circuit breakers. Circuit breakers protect against electrical overloads. This receptacle is a 120/240V 50A NEMA 14-50R receptacle. This receptacle accepts a NEMA plug number 14-50P. Use this receptacle if installing a transfer switch. This locking device is a 120/240V 30A NEMA L14-30R receptacle. This receptacle accepts a NEMA plug number L14-30P. This locking device is a 120V 30A NEMA L5-30R receptacle. This receptacle accepts a NEMA plug number L5-30P. The generator has a control panel with two duplex (two receptacles in a common housing) receptacles. Each duplex is a 120 volt (V) 20 amp (A) straight blade receptacle, National Electrical Manufacturer’s Association (NEMA) number 5-20R. This receptacle accepts NEMA plug numbers 5-15P and 5-20P. Each duplex is capable of drawing 20A at 120V. Refer to your Honda engine manual for oil change recommendations. The engine and generator head is mounted on rubber cylinders that absorb most of the engine vibration. This feature eliminates the tendency of the machine to “walk” which is common in engine powered equipment. Refer to your Honda engine manual. Large tank allows for extended run capabilities. Always allow room for gasoline expansion by not filling the gas tank completely full. The engine key switch is located on the front of the engine. Always locate this switch and be familiar with its location before operating the generator. Used during cold starts. Refer to the starting/stopping instructions and the Honda engine manual for usage. Refer to your Honda engine manual for muffler maintenance. Honda oil filter The battery box provides protection for the battery, and will accept the standard lawn tractor size battery (Group U1-7). The engine requires a 12 volt battery. See battery section for sizing. The generator tank has an ON-OFF valve mounted underneath the tank. Always keep this valve closed when the generator is not in use. The electricity producing part of the generator. The gas cap is extra large, creating a large hole for refilling and a comfortable grip. You can always monitor the fuel level without removing the cap by using the fuel level indicator built into the gas cap.
9
Power Load Planning & Management
NEVER exceed the rated wattage capacity of your generator.
WARNING
OVERLOADING may cause SERIOUS DAMAGE to the generator and attached electrical devices, and may result in fire.
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage of the devices you will be powering. Before using your generator, determine the running and starting wattage requirements of all the electrical devices you will be powering simultaneously. The sum of the running and starting wattages of the devices being powered must not exceed the continuous output rating of your generator. (The continuous output rating of your generator is listed in the “Specifications” section of this manual.) Note that:
Devices without electric motors such as light bulbs, radios, and televisions have the same running and starting wattage.
Devices with electric motors such as refrigerators, compressors, and hand tools typically require a starting wattage that is 3 to 5 times greater than the running wattage.
The running and starting wattage requirements are often listed on a device’s nameplate. If wattage is not given on the device’s nameplate, the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage, Watts = Volts X Amps.
Example conversion to watts:
120 Volts X 5 Amps = 600 Watts
If only the running voltage is given on the nameplate for a device with an electric motor, the starting wattage can be approximated to be three to five times the running wattage.
Estimates for the running wattage requirements for common devices are listed in Table 1 below. Guidance for starting wattages is provided in the table’s footnotes.
Table 1
Device
Air conditioner (12.000 BTU) 1700 (a,b) Jet pump 800 (a) Battery charger (20 Amp) 500 Lawn mower 1200 Belt sander (3”) 1000 Light bulb (100 Watt) 100 Chain saw 1200 Microwave oven 700 Circular saw (6½”) 2000 (a,b) Milk cooler 1100 (a) Coffee maker 1800 (a,b) Oil burner on furnace 300 Compressor (1 HP) 1400 (a,b) Oil-fired space heater (140,000 Btu) 400 Compressor (3/4 HP) 1800 (a) Oil-fired space heater (85,000 Btu) 225 Compressor (1/2 HP) 1400 (a) Oil-fired space heater (30,000 Btu) 150 Curling iron 700 Oven 4500 Dishwasher 1200 Paint sprayer, Airless (1/3 HP) 600 (a) Edge trimmer 500 Paint sprayer, Airless (handheld) 150 Electric nail gun 1200 Radio 200 Electric range (1 element) 1500 Refrigerator 600 (b) Electric skillet 1250 Slow cooker 200
Running
Watts Device
Running
Watts
10
Power Load Planning & Management (cont’d)
Device
Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/2 HP) 2800 (a) Freezer 800 (b) Submersible pump (1 HP) 2000 (a) Hair dryer 1200 Submersible pump (1/2 HP) 1500 (a) Hand drill (1”) 1100 Sump pump 600 (a) Hand drill (1/2”) 875 Table saw 2000 (a) Hand drill (3/8”) 500 Television 500 Hand drill (1/4”) 250 Toaster 1000 Hedge trimmer 450 Vacuum cleaner 250 Home computer 150 VCR 70 Impact wrench 500 Water Heater 3000 Weed trimmer 500
(a) Hard-starting motors require 3-5 times the rated running watts (b) For extremely hard to start loads such as air conditioners and air compressors, consult the equipment dealer to
determine maximum wattage
Running
Watts Device
Running
Watts
To calculate the running and starting wattage requirements for the devices you will be powering, follow these steps:
1. Make a list of all electrical devices you will be powering at the same time with the generator.
2. List the greater of the running or starting wattage next to each device as obtained from the
devices’ nameplate or Table 1. If only the running wattage for a device with an electric motor is known, the starting wattage can be estimated to be at least 3 times the running wattage.
3. Add the wattages for all devices on your list. This total must be lower than the continuous output rating of your generator.
Example:
Device to be Powered
Starting/Running Wattage
Greater of
Light Bulb 75 W Refrigerator – 18 Cu. Ft. 1600 W Microwave 700 W Window AC 1800 W Sump pump (1/3 hp) 2100 W
Total 6275W
In this example, the generator must have a continuous output of at least 6275 W in order to power all of the devices simultaneously.
STAGGERING LOADS
You can increase the number of devices your generator can power by staggering the load on the generator. For example, you could alternately power your refrigerator and air conditioner for limited periods of time -- powering only one of the devices at a time and never powering both at the same time.
11
Installation / Initial Set-Up
There are a number of important steps required to set up your generator for initial use. These steps are:
Each of these steps is discussed in detail below:
You should inspect the generator immediately after you receive delivery.
If you have missing components, contact Product Support at 1-800-270-0810.
If you have damaged components, contact the freight company that delivered the unit and file a
Plan your power load so that you do not exceed the generator’s rated capacity. See the “Power Load Planning & Management” section of this manual to review how to plan and
manage power loads for the generator.
Steps for Installation / Initial Set-Up
1. Unpacking & delivery inspection.
2. Planning the power load to stay within the generator’s rated capacity.
3. Setting up generator for the type of power generation you need:
a. portable power source, or b. connected to a building as a back-up power source.
4. Selecting a site for using the generator.
5. Grounding.
6. Battery installation (electric start models only).
1. Unpacking & Delivery Inspection
See the “Machine Component Identification” section of this manual for a diagram of the generator and its components.
claim.
2. Planning the Power Load
12
Installation / Initial Set-Up
3. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source
This generator is designed to provide up to 13,000W of electrical power. It can supply electricity in two ways:
1. As a back-up, standby power source for a building. For this application, you must arrange
for a licensed electrician to connect the generator to your building’s electrical system via the installation of an UL-approved transfer switch accordance with building electrical code and guidelines supplied by your power company.
2. As a portable power source. You can plug appliances or tools directly into the generator’s
electrical outlets.
Specific requirements for each are given below.
Note: Regardless of whether you use your generator as a back-up power source connected to a
building or as a portable power source, you must not overload the generator. Overloading may cause serious damage to the generator and attached electrical devices.
Using as a Back-up Power Source for a Building
Contact a licensed electrician to install a UL-approved transfer switch if
you want to use your generator as a back-up power source for a building. What does a transfer switch do? It:
a) Safely connects the generator to your building’s electrical system by
isolating your generator from your utility company’s power lines, AND
b) Connects your generator to a critical subset of your building’s circuits
that are needed for emergency power needs.
If your generator will be connected to your building’s electrical system, it MUST ALWAYS be isolated from the utility power grid with a UL-approved transfer switch installed by a licensed electrician in compliance with all applicable building and electrical codes, and in accordance with guidelines supplied by your power company.
DANGER:
A transfer switch must be installed in order to isolate your generator from the utility power grid. If your generator is NOT properly isolated from the utility system, serious hazards will arise: When your generator is running, it’s output will back feed into
the utility power line and transformer that are normally used to provide you with power. The transformer will step up the current to the normal line voltage. An unsuspecting utility line worker working on what he thinks is a deactivated line could be electrocuted.
If your generator is connected (running or not) when utility
power is restored, your generator will be destroyed. It could also explode or cause fire.
In addition to isolating your generator from the utility system, the transfer switch connects your generator to a limited set of circuits in your building that have been chosen as critical to operate during a power outage.
. The transfer switch must be installed in
13