RadiatedCanadaICES-003/CISPR22 Class BANSI C63.4
Emissions USFCC Part 15/CISPR22 Class B ANSI C63.4
UKEN55022ANSI C63.4
Conducted CanadaICES-003/CISPR22 Class BANSI C63.4
Emissions United States FCC Part 15/CISPR22 Class B ANSI C63.4
UKEN 55022ANSI C63.4
EN50082-1
SafetyCanadaCSA C22.2 No. 950-95 (CUL)
USUL 1950 edition 3
UKEN 60950
InternationalIEC 950 edition 2
1
NOTE
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. The limits are designed
to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
WARNING
Use only UL CSA/cUL approved Class 2 Wall Mount
Power Supply with a rated output of 12VAC.
DS30/Station Port AdapterInstallation Guide
2
PRODUCT DESCRIPTION
Table 2. Product Description
CONNECTOR RJ-45 JacksTwo RJ-45 jacks each accepting up to
INTERFACESfour TCM Loops
DS-30 FiberOne female DS-30
Connectorfiber optic connector pair
PowerOne barrel jack for internal
Connectorpower supply to wall mounted 12 VAC
power source
SIZEApprox. 9.75” (248 mm) x 5.06” (129 mm) x 1.22”
(36mm)
WEIGHTEstimated 20 ounces (567 grams) includes bezel and
PCB but not wall-mounted power supply
POWER
RELIABILITY Mean time before failure (MTBF) target is greater than
FUNCTIONAL Multiplexes up to eight Nortel Norstar TCM Loops
DESCRIPTION (up to 16 voice paths) into one DS-30 fiber optic
CountryOutput/Input Rating
North America12VAC @ 600mA/110VAC
United Kingdom12VAC @ 600mA/240VAC
Australia12VAC @ 600mA/240VAC
20 years using Mil-Std-217F method TBD reliability
calculations.
line. Each TCM Loop may include up to two active
voice/data paths as well as a control signaling path.
14 7
2 5 8
3 6
TCM
Loop
Status
LEDs (8)
FIBER
LINE
POWER
AC Power
Connector
DS - 30
FIBER OPTIC
DS30 Fiber
Connector
RJ-45 Connectors
TCM
TCM
Loops
Loops
1-4
5-8
KSU 1- 4
KSU 5 - 8
Fiber Line Status LED
Figure 1. DS-30/Station Port Adapter
Installation GuideDS30/Station Port Adapter
INSTALLATION
1. Connect the TCM Loops from the KSU to a male RJ-45 connector
using the wiring scheme in Figure 2 below. Connect up to 8 TCM
Loops with TCM Loops 1 to 4 in RJ-45 connector 1 and TCM Loops 5
to 8 in RJ-45 connector 2.
2. Insert KSU RJ-45 male connector(s) into the appropriate female RJ-45
connector in the adapter.
3. Insert DS-30 fiber connector of fiber line from Applications Module
into DS-30 Fiber Connector of adapter.
4. Plug power cord into AC Power Connector.
5. Plug the adapter power into an AC wall outlet.
CSA/cUL approved Class 2 Wall Mount Power Supply with a rated
output of 12VAC.
To Adapter
RJ-45
Connector
➝
WARNING: Use only UL
To Adapter
RJ-45
Connector
➝
3
Female RJ-45
JP1
TCM Loops 1-4
Pins 1-8
Loops 1-4
8 7 6 5 4 3 2 1
4- 3- 2- 1- 1+ 2+ 3+ 4+
➝
To Norstar KSU
Female RJ-45
JP1
TCM Loops 5-8
Pins 1-8
Loops 5-8
8 7 6 5 4 3 2 1
8- 7- 6- 5- 5+ 6+ 7+ 8+
➝
To Norstar KSU
Figure 2. TCM Loop RJ-45 Pinout Connections
DS-30/Station Port Adapter
14 7
2 5 8
FIBER
DS - 30
3 6
LINE
POWER
KSU 1- 4
KSU 5 - 8
FIBER OPTIC
Norstar KSUApplications Module
Fiber
Spool
Figure 3. Installation Diagram
DS30/Station Port AdapterInstallation Guide
4
TROUBLESHOOTING
Table 3. Troubleshooting Guide
SITUATIONINDICATIONLINKACTION
Fiber Line LED light isPower onInvalidCheck fiber
flashingconnection between
units
Fiber Line LED light is offNo PowerInvalidCheck power source
Fiber Line LED light is onPower onValidNone
TCM Loop LED port lightActive portValidNone
is onconnection
TCM Loop LED port lightInactive portInvalidCheck corresponding
is offconnectionport connection
The DS30/Station Port Adapter is compatible with ACCESS 2.6
ver. 6.52 and higher within application products running on the
NAM II platform. Systems with previous versions of ACCESS
should obtain an appropriate upgrade.
TCM Loop 1
14 7
Fiber Line
2 5 8
3 6
Figure 4. Close-up View of LEDs
Installation GuideDS30/Station Port Adapter
FIBER
LINE
Norstar is a trademark of Northern Telecom.
P0878745 Issue 01