Nortel Networks CTA 500dm User Manual

dm
dm
dm
dm
dm
CTA 500
The CTA 500 digital modem (CTA 500 dm ) is an optional device used with the Norstar Integrated Communication System (ICS). With ICS software, using release 2.0 or higher, the CTA 500 provides integrated desktop solutions for digital networking applications. With optional Norstar Telephony API Service Provider (TAPI SP), the CTA 500
also supports Computer Telephony Integration (CTI) services required for today's ofÞce environment. With the CTA 500
you can access remote computers on networks including the Internet. You can also telecommute over a digital telephone network and access the CTA 500 CTA 500
allows you to access high-speed network features in
in your ofÞce. The
your ofÞce from your home telephone.
Internet
Service Provider
ISDN
Digital line
Norstar
ICS
Digital line
Norstar
ICS
CTA 500dm
CTA 500dm
LAN
Computer terminal Computer terminal
The CTA 500
P0873832 Issue 05 CTA 500
dm
in the Digital Network
Computer terminal
Norstar telephone
dm
On Line Guide
2
dm
dm
dm
dm
dm
dm
CTA 500dm
The CTA 500 dm serves as a digital modem and terminal adapter (TA). A terminal adapter is a device that allows non-ISDN devices to work with ISDN. It provides reliable high speed end-to-end digital connectivity between your computer and a remote data server using the ICS and the public switched telephone network (PSTN) or Integrated Services Digital Network (ISDN). The CTA 500 supports Point-to-Point Protocol (PPP) and Multilink PPP (MP), which are widely supported by Internet service providers (ISPs) for Internet access and corporate data communication networks (Intranets) for remote LAN access. PPP and MP are supported as built-in features of Windows95.
You can also connect a Norstar telephone to the CTA 500
to access Norstar voice services. You can use the same telephone line to simultaneously carry on a conversation while your computer is connected to the Internet or remote LAN with no loss of ICS features. The CTA 500
connects to the ICS using standard
telephone cabling.
MP works with intelligent bandwidth management software in the ICS to provide dynamic bandwidth allocation accessible at your desktop. Norstar station interfaces support two channels that are ßexibly allocated to transmit data, voice, or both. When the attached Norstar telephone is not in use, all bandwidth is allocated for data trafÞc (up to 128 kbit/s). However, if you want to use the phone to answer an incoming call, or place a call using the free line or the intercom, one channel is automatically allocated for the conversation and the data connection continues at 64 kbit/s. When you hang up the telephone, the second channel is automatically reallocated to the data connection.
Using a CTA 500 CTA 500
allows simultaneous PPP/MP data connections and
compliant Norstar TAPI Service Provider, the
TAPI computer telephony integration (CTI) applications on your PC.
CTA 500
In addition, some of the ICS resources normally used for voice applications, such as network access lines and calling line features, can be used for data trafÞc. Network access lines can be shared between CTA 500
s and other trafÞc within the system. Features such as call logging, call restriction, and routing based on time of day can be applied to data trafÞc for facility utilization and management.
dm
On Line Guide P0873832 Issue 05
dm
dm
dm
dm
dm

Applications

CTA 500dm 3
Any PC equipped with Windows95, Internet application software, and a 16550 UART (115.2 kbit/s capability) can use the CTA 500
.
The CTA 500 dm can be used for any application that requires dial-up capability and uses Point-to-Point Protocol.
These applications include
¥ Internet access
¥ remote LAN access
¥ high-speed modem replacement
¥ CTI based applications when Norstar TAPI SP is added
¥ data transmission at up to 64 kbit/s on either channel of an ISDN
link or 56 kbit/s on a T1 trunk
¥ supports Multilink PPP to enable the dial-up connections to use
two channels
Internet access
The CTA 500 dm allows Norstar customers using digital network interfaces on the Norstar ICS to access Internet service providers (ISPs). You can connect an ISP through the public switched digital network (PSDN) using regular dial-up methods.
Dial-Up Networking
You can use the CTA 500 dm for remote LAN access applications when PPP is used to connect to a remote LAN.
Data-to-data transfers
The CTA 500 dm can be used to establish a connection with an ISDN Terminal Adapter (PPP or MP must be supported) or another CTA 500 same ICS through their own CTA 500 through the network. Using the CTA 500
for Þle transfer. You can connect two computers to the
units, or connect them
connection allows analog modems to be replaced with high-speed digital connections. The CTA 500
does not support connection to analog or 56k
modems.
Computer Telephony Integration (CTI)
With a compliant Norstar TAPI SP, the CTA 500 dm allows simultaneous sessions of PPP/MP and CTI based applications to run on PCs.
P0873832 Issue 05 CTA 500
dm
On Line Guide
4
dm
dm
dm
dm
CTA 500dm
CTA 500
dm
feature summary
¥ digital networking using PPP/MP
¥ simpliÞed installation and conÞguration using installation wizard
¥ high-speed network rate (56, 64, 112, or 128 kbit/s)
¥ high-speed serial port support (maximum 115,200 baud)
¥ integrated desktop solutions (Norstar set, data transfer, and CTI)
¥ bonding of two 56/64 kbit/s channels using MP
¥ dynamic bandwidth allocation between voice and data sessions
¥ data transfer using 3.1 kHz audio call type in ISDN
¥ support of Password Authentication Protocol (PAP) and with
PPP connections, Challenge Handshake Authentication Protocol (CHAP)
¥ Hayes AT command dialing and conÞguration
¥ incoming call screening using calling line identiÞcation for
security
¥ in-Þeld software upgrade for feature enhancement
¥ ICS call management feature support (for example, dialing
restrictions, station message detail recording)
¥ ICS default conÞguration for simpliÞed installation

About this document

¥ The First-time setup section has initial installation information.
¥ The Installation and setup section has information on installing
the CTA 500
¥ The ConÞguration section has information on conÞguring the
CTA 500
¥ The Installing Norstar TAPI SP section has information on
setting up Norstar TAPI Service Provider
¥ The Resource sharing section shows how to conÞgure PCs
equipped with CTA 500
¥ The AT commands section details the commands used to
conÞgure the CTA 500
¥ The Troubleshooting section assists you if you experience
problems when using the CTA 500
and conÞguring your PC and ICS.
dm and Norstar TAPI Service Provider.
to act as Dial-Up Servers.
.
.
CTA 500
¥ The Appendix provides important electromagnetic and radio
frequency information.
dm
On Line Guide P0873832 Issue 05
dm
dm
First-time setup
This section guides you through the initial installation and setup of the CTA 500 Productivity Suite CD-ROM. Use the steps listed below to complete the installation.
. Installation is carried out from the Personal
1. Make the physical connections to the CTA 500
See Installation and setup
2. ConÞgure the ICS for the CTA 500 dm .
See Setting up the ICS
3. ConÞgure the Com port on the PC for the CTA 500 dm .
See ConÞguring the PC serial port
4. Install the CTA 500dm and if required, the Norstar TAPI Service
Provider software.
Installing CTA 500dm and Norstar TAPI Service Provider
See
software
.
.
P0873832 Issue 05 CTA 500
dm
On Line Guide
First-time setup
6
CTA 500
dm
On Line Guide P0873832 Issue 05
dm
dm

Installation and setup

You can place the CTA 500 dm on the desk or mount it on the wall. Refer to ÒWall mounting the CTA 500dmÓ on page 8 of this document for the procedure.
Tele-
phone
The CTA 500
KSU
Port
DB-25
9 V dc
Power
LED
has four jacks that are used to connect a Norstar
telephone, an ICS, a computer, and the power supply.
¥ connect a Meridian Norstar telephone to the Terminal jack (use
the telephone cable included with the Norstar set)
¥ connect the ICS wall plug to the Line jack (use the included
6-way modular socket). Depending on the ICS software release, restrictions may apply on the maximum number of ports and the physical ports to which the CTA 500 to the wiring information in
ICS Installation Guide for more
can be connected. Refer
information.
¥ connect the DB-25 connector to the serial port on the PC (use the
included RS-232 cable)
¥ connect the supplied 9 V dc, 0.6 A power adapter to the dc port
(plug the other end of the adapter into a standard three-prong ac outlet)
P0873832 Issue 05 CTA 500
dm
On Line Guide
8
dm
dm
dm
Installation and setup
Wall mounting the CTA 500
CAUTION!
Shock hazard
For protection from shock hazards, the CTA 500 receive power from an Approved Class 2 power pack equipped with a straight plug, center positive connector with a rating of 9 V dc at 0.6 A.
Note:
C-UL certified in Canada, and either UL or NRTL listed in the United States.
The approved power pack must be either CSA or
dm
must
dm
1. Tape the paper template, supplied with the product, to the wall
allowing 12.5 cm (6 in.) clearance for connections to the CTA 500
.
2. Insert the screws as indicated on the template. Use 4 mm (#8)
screws, leaving 6 mm (0.5 in.) of the screw exposed for mounting.
3. Remove the template.
dm
CTA 500
bottom view
4. Mount the CTA 500 dm onto the screws making sure to orient the
connector ports so they are at the top of the CTA 500
5. Route the cables away from the CTA 500
to avoid potential
.
electromagnetic interference.
CTA 500
dm
On Line Guide P0873832 Issue 05

Setting up the ICS

Program the ICS for the CTA 500dm the same way that you program the ICS for a Norstar set. You can program line access, line pool codes and restrictions to apply to outgoing calls. The CTA 500dm must be assigned to a digital line or to a digital line pool. Refer to the ÒTerminals and sets programmingÓ section of your Installer Guide for more information.
The CTA 500dm is a B2 channel device and must be assigned a B2 channel DN. The following table shows the default directory number (DN) that is assigned to the CTA 500dm based on the physical set port that connects the CTA 500dm to the ICS.
Compact ICS Modular ICS
ICS Port Default DN ICS Port Default DN
Installation and setup 9
101 80 123 697 102 81 124 698 103 82 125 699 104 83 126 700 105 84 127 701 106 85 128 702 107 86 129 703 108 87 130 704 109 88 131 705 110 89 132 706
You can change the DN that is assigned to the CTA 500dm in the same way that you change a DN for a Norstar telephone. Refer to ICS Installation Guide for more information.
Note: If you use automatic telephone relocation (set relocation) to
change the port used by a CTA 500dm, you must power down the CTA 500dm before changing the connections. If the CTA 500dm is not powered down, programming information will be lost. See ICS Installer Guide for more information about set relocation.
P0873832 Issue 05 CTA 500
dm
On Line Guide
10 Installation and setup

Setting up the PC

Each PC operating system requires a different set up.
Note: Installation using another vendorÕs protocol stack packages
will differ. See the AT commands section of this document for information on conÞguring advanced operations on the CTA 500dm from your PC. See the Appendix for a list of the DB-25 pins used by the CTA 500dm.
CTA 500dm On Line Guide P0873832 Issue 05
Configuration
Some operations that you can perform with the CTA 500dm include the following:
¥ ConÞguring the PC serial port
¥ Installing CTA 500dm and Norstar TAPI Service Provider
software
Note: Before you begin conÞguration, connect the ICS and the PC
as described in the ÒInstallation and setupÓ section and power up the CTA 500dm.
P0873832 Issue 05 CTA 500dm On Line Guide
12 Configuration
Configuring the PC serial port
¥ Verify the port baud rate is set to 115,200 (default) using the
Serial Interface Rate command.
¥ Set the character length, using the Set Data Bits command and
parity, using the Set Parity command. The default is 8 bits with no parity (recommended).
¥ Set the ßow control using the Flow Control command. The
default is hardware (recommended).
Installing CTA 500dm and Norstar TAPI Service Provider software
1. From the Norstar Personal Productivity Suite main screen, select
the Language, and then the Installation option.
2. After accepting the licensing terms and reading the TAPI
requirements (if displayed), select the Install option.
3. Select the CTA 500dm from the right hand side of the dialog box
(under the Drivers section).
4. On the left hand side of the dialog box, select the components
you wish to install:
Drivers Ñ the required drivers and conÞguration utility for the CTA 500dm
Toolkits Ñ CTE, Norstar TAPI Service Provider (TSP)
Applications
5. Follow the on-screen instructions to select automatic
conÞguration, and to select the proper communications port.
6. Choose the appropriate settings for your installation.
CTA 500dm On Line Guide P0873832 Issue 05
Configuration 13
7. Click Next. A message displays the name assigned to the
installation. If you need more than one init string for the CTA 500dm, refer to ÒAdding multiple CTA 500dm conÞgurationsÓ
on page 16 for the procedure.
8. Click OK.
9. Click Yes to automatically setup Internet access through your
CTA 500dm.
10. Click Next when you see the message indicating that all network
components required are present.
11. Click Yes to automatically setup a connection to your Internet
service provider.
12. Select Norstar CTA 500dm.
13. Click Next.
14. Select one of the Internet service providers from the list or click
None of the above.
15. When the Connect To window displays, enter your user name
and password.
16. Click Next.
P0873832 Issue 05 CTA 500dm On Line Guide
14 Configuration
17. When the Connection Settings dialog box displays, enter the
Internet service provider telephone number.
18. Click Next.
19. The installation is complete and you need to restart your
computer before using the CTA 500dm.
20. Click the Finish button.
Configuring the CTA 500dm (if not configured during installation)
1. From the Windows Start button, navigate to Programs, Norstar
CTA 500dm, CTA 500dm ConÞguration.
2. The CTA 500dm ConÞguration Options dialog box is displayed.
3. Choose the appropriate settings for your installation.
CTA 500dm On Line Guide P0873832 Issue 05
Configure CTA 500dm to access PP/MP data calls
1. Double-click on the My Computer icon on your desktop.
2. Double-click Dial-Up Networking icon.
3. Double-click Make New Connection icon.
4. When the Make New Connection window displays, choose
Norstar CTA 500dm modem from the pull-down menu.
Configuration 15
5. Click the ConÞgure button.
6. Click the Connection tab.
7. Click the Advanced button.
8. In the Advanced Connection Settings window, type AT&D1 in
the Extra settings box.
P0873832 Issue 05 CTA 500dm On Line Guide
16 Configuration
9. Click OK.
10. Close all windows.
Adding multiple CTA 500dm configurations
1. Click the Start button.
2. Choose Programs from the menu.
3. Choose CTA 500dm from the sub-menu.
4. Choose CTA 500dm conÞgurations.
5. Select the ConÞguration tab.
6. Choose settings for the required conÞguration.
7. Click OK.
You now have another CTA 500dm conÞguration with different settings than the Þrst one. Make sure that you note the speciÞc settings when you create the connection icons.
CTA 500dm On Line Guide P0873832 Issue 05

Upgrading the CTA 500dm software

CTA 500dm software upgrades are periodically made available through your Norstar distributor. Contact your Norstar distributor for details about receiving software upgrades.
Use the CTA 500dm conÞguration utility to display current settings or to update software.
1. Click the Browse button.
2. When Þle information displays, click Transmit.
3. Advanced connection settings can be deÞned using the setup
wizard or the Enter Download State command.
Configuration 17
Uninstalling the CTA 500
1. Open the Control Panel.
2. Open Modems.
3. Select the CTA 500dm conÞguration that you want to uninstall.
4. Click Remove.
Note: You must select another modem for any remaining
Dial-Up Networking connections.
If you need to completely uninstall the CTA 500dm, remove all CTA 500dm conÞgurations and delete the CTA 500dm directory and program group.
dm
P0873832 Issue 05 CTA 500dm On Line Guide
18 Configuration
CTA 500dm On Line Guide P0873832 Issue 05

Installing Norstar TAPI SP

To use a CTA 500dm for TAPI applications, Norstar TSP must be installed. It can be installed at the same time as the CTA 500dm software via the Personal Productivity Suite (PPS) installation procedure, or it can be installed later from the PPS CD.
Note: The current CTA 500dm conÞguration does not support
dynamic bandwidth allocation if you donÕt have access to a line pool with more than two ISDN lines. When you are making an MP data call and want to make a voice call at the same time, lift the telephone handset in order to make a channel available for the call.
Configure TAPI dialing properties
If you use an access code to get an external line or get a private network line to make a long distance call (for example, dial 9 before dialing an external number or dial 6 before dialing a long distance number), you need to conÞgure the Norstar set attached to the CTA 500dm.
1. Click the Start button and move the cursor to Settings.
2. Choose Control Panel from the sub-menu.
3. When the Control Panel window displays, double-click the
Telephony icon.
4. When the Telephony Properties window displays, click the
Dialing Properties button.
P0873832 Issue 05 CTA 500dm On Line Guide
20 Installing Norstar TAPI SP
5. In the Dialing properties window, locate To access an outside
line, first dial: and enter x for local (where x represent s the
access code) and when applicable, y for long distance (where y represents the code to access a private network).
6. Click OK.
7. Close all windows.

Installing Personal Call Manager

The Personal Call Manager (PCM) application is supplied on the Norstar Personal Productivity Suite (PPS) CD-ROM.
1. From the PPS main screen, select the Language, and then the
Installation option.
2. After accepting the licensing terms and reading the TAPI
requirements (if displayed), select the Install option.
3. On the left hand side of the dialog box, select Applications and
then select PCM from the right hand side of the dialog box.
CTA 500dm On Line Guide P0873832 Issue 05
4. As the installation progresses, choose the appropriate options
and click the Next button as required.
5. Once the Setup Complete window displays, click the Finish
button. The program is installed and a PCM icon appears on the desktop.
6. To access the program, double-click the PCM icon.
Using PCM for the first time
When the PCM software is installed, you need to choose a TAPI line to enable PCM to use a TAPI-enabled device. You can change the TAPI line at any time by choosing Dial Using from the Tools menu, which calls up the Choose a TAPI line window.
1. Double-click on the PCM icon on the desktop. The PCM
program loads and the Choose A TAPI line window displays on top of the program.
Installing Norstar TAPI SP 21
2. Use the pull-down menu to select the line for TAPI connection.
3. In the Address: box choose Default for a typical user
conÞguration or pull down the menu and select your line number to use a speciÞc line for all calls.
4. Click OK.
5. After restarting your PC, Personal Call Manager is ready for use.
Note: Whenever you make a change in the Choose a TAPI Line
window (connection, address, or both), you must restart your PC for the change to take effect.
Note: If your prime line is Intercom, you must have line pool access
codes in the Dialing Properties dialog box to make external calls. These line pool access codes will be used for both data and voice calls.
P0873832 Issue 05 CTA 500dm On Line Guide
22 Installing Norstar TAPI SP
Note: Refer to the Nortel ITAS web page for tips and information
on other conÞgurations.
CTA 500dm On Line Guide P0873832 Issue 05

Resource sharing

You can access information, software or peripheral devices (such as printers) that are installed on another PC from your PC when both PCs are equipped with a CTA 500dm and Win95 Plus! Dial-Up Server software.
Note: Dial-Up Server software is available from either the
Microsoft Plus! Pack or ISDN Accelerator Pack.
To share resources, complete the following sections:
¥ Installing Dial-Up Server
¥ Allowing access to your PC
¥ Connecting to a Windows 95 Dial-Up Server
¥ Connecting to Resources on the Dial-Up Server
P0873832 Issue 05 CTA 500dm On Line Guide
24 Resource sharing

Installing Dial-Up Server

If you use your PC to dial into other PCs, enable NetBEUI in the Server Types window. If other PCs will be dialling into your PC, enable IP, IPX and NetBEUI.
1. Install Dial-Up Server from either the Plus! Pack or the ISDN
Accelerator Pack.
2. Open My Computer.
3. Open Dial-Up Networking.
4. From the Connections menu, select Dial-Up Server.
5. Select Allow caller access.
6. Select Change Password to apply a password to the connection.
A password is recommended but is not mandatory when using Dial-Up Server.
7. Information that is entered in the Comment Þeld is displayed to
other PCs that attempt to dial in to your PC.
8. Click Apply.
The Status changes to Monitoring. When another PC dials in, the Status changes to Answering. Once a connection is established the guest PCÕs login name is shown.

Allowing access to your PC

1. Open My Computer.
2. Open the Control Panel.
3. Open Network.
4. Select the IdentiÞcation tab.
CTA 500dm On Line Guide P0873832 Issue 05
Resource sharing 25
The Computer Name is required by PCs attempting to access your PC.
5. Close the Network window. The Control Panel window is still
open.
6. Select one resource that you want to make available to other
PCs, (for example, fax machine) and select it.
7. From the File menu select Properties.
8. Click the Sharing tab.
9. Select Shared As.
10. Enter a Share Name, any applicable Comment, and a Password.
The Share Name and Password are required by PCs attempting to access your PC.
11. Close all open windows.

Connecting to a Windows 95 Dial-Up Server

1. Double-click the My Computer icon on the desktop.
2. Open Dial-Up Networking.
3. Select the CTA 500dm modem.
4. Use the File pull-down menu to choose Properties.
5. Click the Server Type... button.
6. Add a connection in Dial-Up Networking on the client PC with
the phone number of the CTA 500dm as the Dial-Up Server PC.
Note: You do not need to bring up a Terminal Window after
dialing.
P0873832 Issue 05 CTA 500dm On Line Guide
26 Resource sharing
7. Select PPP: Windows95,... as Type of Dial-Up Server.
8. Check the to network box in Advanced options.
9. Check NetBEUI for Allowed Network Protocols.
10. Click OK.
11. Click OK.
In the Dial-Up Networking window, double-click the icon of the modem you want to connect. The name and password are not yet required.

Connecting to Resources on the Dial-Up Server

Method one
1. Right-click on Network Neighborhood.
2. Select Find Computer.
3. Enter the name of the computer that you want to browse.
4. Click on the Find Now button.
Method two
1. Click on the Start button.
2. Move the cursor to Programs.
3. Select Windows Explorer from the sub-menu.
4. From the Tools menu, select Map Network Drive.
5. Enter the Drive letter you want to use. The default letter is the
Þrst available Drive. Windows Explorer will display the
CTA 500dm On Line Guide P0873832 Issue 05
Loading...