![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg1.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
Description
NT0X10AA PCP, SCAN, MISCELLANEOUS 02 C C C C C C C C C C C
NT2T00AA PCP, LINE, SINGLE PARTY C C C C C C C C C C C C
402.52 NOTE: VINTAGES F,G,H,J ARE NOT COMPATIBLE.
402.53 NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES F,G,H,J ARE NOT COMPATIBLE.
403.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T00AB PCP, LINE, SINGLE PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGES A,B,C,G ARE NOT COMPATIBLE.
402.53 NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES A,B,C,G ARE NOT COMPATIBLE.
403.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: ALL VINTAGES COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T00AC PCP, LINE, SINGLE PARTY C C C C C C C C C C C C
402.52 NOTE: VINTAGES C THROUGH J ARE NOT COMPATIBLE.
402.53 NOTE: VINTAGES C THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES C THROUGH J ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGES C THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGES C THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGES C THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGES C THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T00AD PCP, LINE, SINGLE PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGES A THROUGH G ARE NOT COMPATIBLE.
402.53 NOTE: VINTAGES A THROUGH G COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES A THROUGH G ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGES A THROUGH G COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGES A THROUGH G COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGES A THROUGH G COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGES A THROUGH G COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T00BB PCP, LINE, SINGLE PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGES A AND B ARE NOT COMPATIBLE.
402.53 NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES A AND B ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 1
![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg2.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
406.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T00BC PCP, LINE, SINGLE PARTY A C C C C C C C C C C C
NT2T01AA PCP, LINE, 2-PARTY E C C C C C C C C C C C
NT2T01AB PCP, LINE, 2-PARTY A C C C C C C C C C C C
NT2T01BA PCP, LINE, 2-PARTY A C C C C C C C C C C C
NT2T01BB PCP, LINE, 2-PARTY A C C C C C C C C C C C
NT2T02BA PCP, LINE, 4-PARTY, ANI B C C C C C C C C C C C
NT2T03AA PCP, LINE, MISC. FUNCTION G C C C C C C C C C C C
NT2T03AB PCP, LINE, MISC. FUNCTION A C C C C C C C C C C C
NT2T03BB PCP, LINE, MISC. FUNCTION A C C C C C C C C C C C
NT2T03CA PCP, LINE, MISC. FUNCTION B C C C C C C C C C C C
NT2T04AA PCP, LINE, COIN, PREPAY J C C C C C C C C C C C
NT2T04BA PCP, LINE, COIN, PREPAY A C C C C C C C C C C C
NT2T05AA PCP, LINE, 8-PARTY H C C C C C C C C C C C
402.52 NOTE: VINTAGE H WITH GREEN DOT IS NOT COMPATIBLE.
402.53 NOTE: VINTAGE H WITH GREEN DOT COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGE H WITH GREEN DOT IS NOT COMPATIBLE.
403.XX NOTE: VINTAGE H WITH GREEN DOT COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGE H WITH GREEN DOT COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGE H WITH GREEN DOT COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGE H WITH GREEN DOT COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T05AB PCP, LINE, 8-PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGE A AND B ARE NOT COMPATIBLE.
402.53 NOTE: VINTAGE A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGE A AND B ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGE A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGE A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGE A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGE A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T05AC PCP, LINE, 8-PARTY G C C C C C C C C C C C
NT2T05AD PCP, LINE, 8-PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGE A THROUGH J ARE NOT COMPATIBLE.
402.53 NOTE: VINTAGE A THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGE A THROUGH J ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGE A THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGE A THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGE A THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGE A THROUGH J COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T05BB PCP, LINE, 8-PARTY A C C C C C C C C C C C
402.52 NOTE: VINTAGES A AND B ARE NOT COMPATIBLE.
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 2
![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg3.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
402.53 NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
403.1X NOTE: VINTAGES A AND B ARE NOT COMPATIBLE.
403.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
404.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
405.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
406.XX NOTE: VINTAGES A AND B COMPATIBLE IF MINIMUM NT4T05AD EQUIPPED.
NT2T07AA PCP, LINE, 2-PARTY, MF C C C C C C C C C C C C
NT2T07BA PCP, LINE, 2-PARTY, MF A C C C C C C C C C C C
NT2T08AA PCP, LINE, 2-PARTY, EXTENDED RANGE B C C C C C C C C C C C
NT2T08BA PCP, LINE, 2-PARTY, EXTENDED RANGE A C C C C C C C C C C C
NT2T09AA PCP, LINE, 8-PARTY, EXTENDED RANGE C C C C C C C C C C C C
NT2T09BA PCP, LINE, 8-PARTY, EXTENDED RANGE A C C C C C C C C C C C
NT2T10AA PCP, RECEIVER, MULTIFREQUENCY C C C C C C C C C C C C
NT2T10AB PCP, RECEIVER, MULTIFREQUENCY A C C C C C C C C C C C
NT2T10BA PCP, RECEIVER, MULTIFREQUENCY A C C C C C C C C C C C
NT2T10BB PCP, RECEIVER, MULTIFREQUENCY A C C C C C C C C C C C
NT2T11AA PCP, RECEIVER, DIGITONE D C C C C C C C C C C C
NT2T11AB PCP, RECEIVER, DIGITONE A C C C C C C C C C C C
NT2T11BA PCP, RECEIVER, DIGITONE B C C C C C C C C C C C
NT2T11BB PCP, RECEIVER, DIGITONE A C C C C C C C C C C C
NT2T12AA PCP, CONTROL, PERIPHERAL, #1 H C C C C C C C C C C C
NT2T13AA PCP, CONTROL, PERIPHERAL, #2 C C C C C C C C C C C C
NT2T13AB PCP, CONTROL, PERIPHERAL, #2 A C C C C C C C C C C C
NT2T13AC PCP, CONTROL, PERIPHERAL, #2 A C C C C C C C C C C C
NT2T14AA PCP, ACCESS, PERIPHERAL MAINT B C C C C C C C C C C C
NT2T16AA PCP, TRUNK, TEST, INCOMING H I I I I I I I I I I I
NT2T16BA PCP, TRUNK, TEST, INCOMING A I I I I I I I I I I I
NT2T16CA PCP, TRUNK, TEST, INCOMING E C C C C C C C C C C C
405.XX NOTE: MAY BE USED WHEN METALLIC LINE TESTING FOR SLC-96 IS NOT REQUIRED
406.XX NOTE: MAY BE USED WHEN METALLIC LINE TESTING FOR SLC-96 IS NOT REQUIRED
40X.XX NOTE: NOT COMPATIBLE WHERE SLC-96 IS INTERFACED.
NT2T16CB PCP, TRUNK, TEST, INCOMING C C C C C C C C C C C C
405.1 NOTE: MINIMUM WHEN METALLIC LINE TESTING FOR SLC-96 IS REQUIRED.
40X.XX NOTE: MINIMUM REQUIRED IN HOST AND PE BASED REMOTES.
NT2T17AA PCP, INTERFACE, NOLLER/BADGER C I I I I I I I I I I I
NT2T17BA PCP, TRUNK, TEST, NOLLER B I I I I I I I I I I I
NT2T17CA PCP, TRUNK, TEST, NOLLER A C C I I I I I I I I I
NT2T17CB PCP, TRUNK, TEST, NOLLER A C C C C C C C C C C C
40X.XX NOTE: MINIMUM REQUIRED IN HOST AND PE BASED REMOTES.
NT2T19AA PCP, TEST, LINE & TRUNK S I I I I I I I I I I I
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 3
![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg4.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
NT2T19AB PCP, TEST, LINE & TRUNK A I I I I I I I I I I I
NT2T19AC PCP, TEST, LINE & TRUNK A C C C C C C C C C C C
40X.XX NOTE: MINIMUM REQUIRED IN HOST AND PE BASED REMOTES.
NT2T20AA PCP, TRUNK, 4-WIRE E & M D C C C C C C C C C C C
NT2T20AB PCP, TRUNK, 4-WIRE E & M B C C C C C C C C C C C
NT2T20BB PCP, TRUNK, E & M, 4-WIRE R C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR STYLE C. STYLE A B/L IS VTG B.
NT2T20CA PCP, TRUNK, 4W E&M, DP, REMOTE A C C C C C C C C C C C
40X.XX NOTE: USED IN PE REMOTES ONLY.
NT2T20CB PCP, TRUNK, E & M,4-WIRE,DP,REM A C C C C C C C C C C C
40X.XX NOTE: USED IN DMS-10 HOST & PE REMOTES.
NT2T21AA PCP, TRUNK, E & M, 2-WIRE E C C C C C C C C C C C
NT2T21AB PCP, TRUNK, E & M, 2-WIRE B C C C C C C C C C C C
NT2T21BB PCP, TRUNK, E & M, 2-WIRE S C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR STYLE C. STYLE A B/L IS VTG A.
NT2T21CA PCP, TRUNK, 2W E&M, REMOTE B C C C C C C C C C C C
40X.XX NOTE: USED IN PE REMOTES ONLY.
4XX.XX NOTE: B/L VTG SHOWN IS FOR STYLE C. STYLE A B/L IS VTG A.
NT2T21CB PCP, TRUNK, 2W E&M, REMOTE A C C C C C C C C C C C
40X.XX NOTE: USED IN DMS-10 HOST & PE REMOTES.
NT2T23AA PCP, TRUNK, MISC. LOOP D C C C I I I I I I I I
404.3X NOTE: & HIGHER GENERICS CAN'T BE USED IN OUTGOING TRUNK; INCOMING ONLY
NT2T23BA PCP, TRUNK, LOOP, MISC. A C C C I I I I I I I I
404.3X NOTE: & HIGHER GENERICS CAN'T BE USED IN OUTGOING TRUNK; INCOMING ONLY
NT2T24AA PCP, TRUNK, LOOP, OUTGOING G C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR STYLE B. STYLE A B/L IS VTG F.
NT2T24BA PCP, TRUNK, LOOP, OUTGOING B C C C C C C C C C C C
NT2T25AA PCP, NETWORK, COMPROMISE A C C C C C C C C C C C
NT2T26AA PCP, CIRCUIT BREAKER B C C C C C C C C C C C
NT2T27AA PCP, TRUNK, E & M, 4-WIRE A C C C C C C C C C C C
NT2T27AB PCP, TRUNK, 4-WIRE E & M A C C C C C C C C C C C
NT2T27BB PCP, TRUNK, E&M, 4-WIRE, W/PAD A C C C C C C C C C C C
NT2T27CA PCP, TK, 4W E&M W/PAD, DP, REM A C C C C C C C C C C C
NT2T30AA PCP, INTERFACE, NETWORK B C C C C C C C C C C C
NT2T31AA PCP, SIGNALING CONVERTER B C C C C C C C C C C C
NT2T32AA PCP, INTERFACE, CARRIER B C C C C C C C C C C C
40X.XX NOTE: COMPATIBLE WITH DCM APPLICATIONS ONLY.
NT2T32AB PCP, INTERFACE, CARRIER C C C C C C C C C C C C
40X.XX NOTE: COMPATIBLE WITH DCM APPLICATIONS ONLY.
NT2T32AC PCP, INTERFACE, CARRIER A C C C C C C C C C C C
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 4
![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg5.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
40X.XX NOTE: COMPATIBLE WITH DCM, REQUIRED FOR REM APPLICATIONS.
NT2T32AD PCP, INTERFACE, CARRIER A C C C C C C C C C C C
40X.XX NOTE: REQUIRED FOR OSS FEATURE, BACKWARD COMPATIBLE. MINIMUM FOR J0T13A-1L3 & LATER SHELF.
NT2T32AE PCP, INTERFACE, CARRIER A C C C C C C C C C C C
40X.XX NOTE: REQUIRED FOR OSS FEATURE, BACKWARD COMPATIBLE. MINIMUM FOR J0T13A-1L5 & LATER SHELF.
NT2T33AA PCP, TERMINATOR, 6-LOOP A C C C C C C C C C C C
NT2T34AA PCP, BUFFER, NETWORK B C C C C C C C C C C C
NT2T35AA PCP, CONVERTER, MESSAGE C C C C C C C C C C C C
NT2T36AA PCP, BUFFER, SIGNALING D C C C C C C C C C C C
NT2T37AA PCP, NETWORK, REMOTE B C C C C C C C C C C C
NT2T38AA PCP, MESSAGE, REMOTE B C C C C C C C C C C C
NT2T39AA PCP, SIGNALING, REMOTE B C C C C C C C C C C C
NT2T39AB PCP, SIGNALING, REMOTE A C C C C C C C C C C C
NT2T40AA PCP, AUXILIARY RING & TONE F C C C C C C C C C C C
NT2T40BA PCP, AUXILIARY RING & TONE A C C C C C C C C C C C
NT2T40BB PCP, AUXILIARY RING & TONE A C C C C C C C C C C C
NT2T41AA PCP, CONTROLLER, PE SHELF H C C C C C C C C C C C
NT2T41AB PCP, CONTROLLER, PE SHELF U C C C C C C C C C C C
NT2T41AC PCP, CONTROLLER, PE SHELF A C C C C C C C C C C C
NT2T42AA PCP, CONVERTER, PE SHELF D C C C C C C C C C C C
NT2T42AB PCP, CONVERTER, PE SHELF, AB A C C C C C C C C C C C
NT2T43AA PCP, LINE, ZERO DB, 2-PARTY D C C C C C C C C C C C
NT2T43AB PCP, LINE, ZERO DB, 2-PARTY B C C C C C C C C C C C
NT2T43AC PCP, LINE, ZERO DB, 2-PARTY A C C C C C C C C C C C
NT2T43BB PCP, LINE, 2-PARTY, ZERO DB C C C C C C C C C C C C
NT2T44AA PCP, LINE, ZERO DB, MISC. FUNCTION C C C C C C C C C C C C
NT2T44AB PCP, LINE, ZERO DB, MISC. FUNCTION B C C C C C C C C C C C
NT2T44AC PCP, LINE, ZERO DB, MISC. FUNCTION A C C C C C C C C C C C
NT2T44BB PCP, LINE, ZERO DB, MISC. FUNCTION G C C C C C C C C C C C
NT2T44BC PCP, LINE, ZERO DB, MISC. FUNCTION B C C C C C C C C C C C
NT2T45AA PCP, LINE, ZERO DB, COIN C C C C C C C C C C C C
NT2T45AB PCP, LINE, ZERO DB, COIN K C C C C C C C C C C C
NT2T45BB PCP, LINE, ZERO DB, COIN Z C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR PCB STYLE "B". STYLE "A" B/L IS VTG "P".
NT2T46AA PCP, PROCESSOR, PERIPHERAL F C C C C C C C C C C C
NT2T46AB PCP, PROCESSOR, PERIPHERAL A C C C C C C C C C C C
NT2T47AA PCP, INTERFACE, ALARM, REMOTE A C C C C C C C C C C C
NT2T48AA PCP, SIGNALING, CAMA B C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR PCB STYLE "B". STYLE "A" B/L IS VTG "A".
NT2T48BA PCP, SIGNALING, CAMA A C C C C C C C C C C C
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 5
![](/html/01/01d1/01d1685386fd59d4c8fcb78b669965930d0518f63b9efd6c4457121f6c0cc23b/bg6.png)
DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
NT2T50AA PCP, SWITCH, TIME H C C C C C C C C C C C
NT2T51AA PCP, PROCESSOR, SYSTEM G C C C C C C C C C C C
NT2T52AA PCP, PROCESSOR, B WORD E C C C C C C C C C C C
NT2T53AA PCP, PROCESSOR, A-BIT G C C C C C C C C C C C
40X.XX NOTE: USED FOR SINGLE PARTY LINE CARD APPLICATIONS ONLY.
4XX.XX NOTE: B/L VTG SHOWN IS FOR PCB STYLE "B". STYLE "A" B/L IS VTG "E".
NT2T53AB PCP, PROCESSOR, A-BIT B C C C C C C C C C C C
40X.XX NOTE: USED FOR SINGLE PARTY LINE CARD APPLICATIONS ONLY.
NT2T53AC PCP, PROCESSOR, A BIT A C C C C C C C C C C C
40X.XX NOTE: USED IF DMS-1R HAS MULTI FREQUENCY RINGING.
NT2T54AA PCP, DIGITAL GROUP C C C C C C C C C C C C
NT2T55AA PCP, PROTECTION SWITCH,1 FOR N D C C C C C C C C C C C
NT2T56AA PCP, PROTECTION SWITCH, FAILSAFE D C C C C C C C C C C C
4XX.XX NOTE: B/L VTG SHOWN IS FOR PCB STYLE "B". STYLE "A" B/L IS VTG "B".
NT2T67AA PCP, LINE, ZERO DB, SUPERIMPOSED F C C C C C C C C C C C
NT2T67BB PCP, LINE, ZERO DB, SUPERIMPOSED G C C C C C C C C C C C
NT2T69BA PCP, LINE, ZERO DB, SGL PARTY D C C C C C C C C C C C
NT2T69BB PCP, LINE, ZERO DB, SGL PARTY A C C C C C C C C C C C
NT2T70AA PCP, PROCESSOR, PERIPHERAL MAINT. D C C C C C C C C C C C
40X.XX NOTE: ALIT FEATURE IS NOT SUPPORTED WHEN USED IN DC TEST SHELF.
NT2T70AB PCP, PROCESSOR, PERIPHERAL MAINT. B C C C C C C C C C C C
40X.XX NOTE: MINIMUM VINTAGE B REQUIRED TO SUPPORT ALIT.
NT2T71AA PCP, TEST, PERIPHERAL MAINT. B C C C C C C C C C C C
NT2T72AA PCP, TEST, FACILITY C C C C C C C C C C C C
NT2T73AA PCP, PROCESSOR, SIGNAL C C C C C C C C C C C C
NT2T74AA PCP, PROCESSOR, CONTROL E C C C C C C C C C C C
NT2T85AA PCP, ANNOUNCER, DIGITAL A C C C C C C C C C C C
NT2T85AB PCP, ANNOUNCER, DIGITAL, AB A C C C C C C C C C C C
NT2X06AB PCP, CONVERTER, POWER, 5V/40A 03 C C C C C C C C C C C
NT2X09AA PCP, CONVERTER, POWER, MULTI O/P 05 C C C C C C C C C C C
NT2X10AB PCP, TEST, LOOP AND LINE, ODD 12 C C C C C C C C C C C
40X.XX NOTE: USED WITH REMOTE MAINTENANCE MODULE IN RLCM AND OPM.
NT2X10AC PCP, LINE TEST UNIT, ANALOG 01 C C C C C C C C C C C
40X.XX NOTE: USED WITH REMOTE MAINTENANCE MODULE IN RLCM AND OPM.
NT2X11AA PCP, TEST, LOOP AND LINE, EVEN 4A C C C C C C C C C C C
40X.XX NOTE: USED WITH REMOTE MAINTENANCE MODULE IN RLCM AND OPM.
NT2X11AC PCP, LINE TEST UNIT, DIGITAL 01 C C C C C C C C C C C
40X.XX NOTE: USED WITH REMOTE MAINTENANCE MODULE IN RLCM AND OPM.
NT2X11AD PCP, LINE TEST UNIT, DIGITAL 01 C C C C C C C C C C C
40X.XX NOTE: USED WITH REMOTE MAINTENANCE MODULE IN RLCM AND OPM.
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 6