System prepiped to liquid and suction line "shut off" valves on
condensing unit mounting base.
UL Approved System for outdoor applications
Standard voltages 115/60/1; 208-230/60/1 and 208-230/60/3 (not
all systems available in 115/60/1 or 208-230/60/3)
AVAILABLE OPTIONAL FEATURES OR COMPONENTS
Protective coatings for evaporator coils (high temperature
applications)
Copper fins on evaporator coil
Standard profile evaporator
Vibrasorber on suction line
Vibrasorber on liquid line
Electric defrost for normal temperature systems
Precharged system with quick connect precharged lines
Crankcase pressure regulating valve
Pressure relief valve
Fused Disconnect
All weather hoods
Water cooled condensing units
Special temperature application
5 year compressor warranty
Other voltage including 480/60/3, 220/50/1, etc.
* All refrigeration sized to customer specied product load requirements.
** Scroll compressors used on certain hermetic applications.
** Consult factory for compressor style available on specic systems.
SPECIFICATION
GUIDE
Page 2
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Welded Hermetic Refrigeration Systems
35˚F Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
16 Hour Run Time
CONDENSING UNITUNIT COOLER
MODEL
NUMBER
NAWD50RL010.514.820ASA18-53BA27.5L x 15D x 15.25H1.0155,2234,802R-404A15.320
NAWD75RL49.012.415ASA18-66BA27.5L x 15D x 15.25H1.0156,2905,449R-404A15.420
NAWD125RL47.011.715ASA28-76BA41.5L x 15D x 15.25H2.0158,6647,822R-404A13.715
NAWD125RL34.78.815ASA28-76BA41.5L x 15D x 15.25H2.0158,6647,822R-404A10.815
NAWD150RL412.416.520ASA28-106BA 41.5L x 15D x 15.25H2.01510,2489,407R-404A18.520
NAWD150RL37.512.215ASA28-106BA 41.5L x 15D x 15.25H2.01510,2489,407R-404A14.220
NAWD200RL410.915.920BSA28-134BA 41.5L x 15D x 15.25H2.01513,27512,434R-404A17.920
NAWD200RL3NA11.715BSA28-134BA 41.5L x 15D x 15.25H2.01513,27512,434R-404A13.715
NAWD225RL413.817.825BSA38-160BA 63.5L x 15D x 15.25H3.01514,98813,726R-404A20.825
NAWD225RL3NA13.720BSA38-160BA 63.5L x 15D x 15.25H3.01514,98813,726R-404A16.720
NAWD300RL416.025.835BSA48-212BA 81.5L x 15D x 15.25H4.01519,66317,981R-404A29.835
NAWD300RL3NA18.820BSA48-212BA 81.5L x 15D x 15.25H4.01519,66317,981R-404A22.825
NAWD325RL420.029.140BSA48-212BA 81.5L x 15D x 15.25H4.01521,23119,548R-404A33.140
NAWD325RL3NA20.125BSA48-212BA 81.5L x 15D x 15.25H4.01521,23119,548R-404A24.125
NAWDA400RL426.433.550CCSA68-318BA 117.5L x 15D x 15.25H6.01531,21028,686R-404A39.550
NAWD400RL3NA23.135CCSA68-318BA 117.5L x 15D x 15.25H6.01531,21028,686R-404A29.135
NAWD500RL433.742.060CCSA68-390CA 117.5L x 15D x 15.25H6.01534,85332,329R-404A48.050
NAWD500RL3NA27.040CCSA68-390CA 117.5L x 15D x 15.25H6.01534,85332,329R-404A33.040
COMP
RLA
COND
MCA**
UNIT
C.U.
MAX
FUSE**
RACK
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 3
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Welded Hermetic Refrigeration Systems
-10˚F Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
20 Hour Run Time
CONDENSING UNITELECTRIC DEFROST UNIT COOLER
MODEL
NUMBER
LAWD75RL411.014.920ASE16-41BD27.5L x 15D x 15.25H4.4152,9832,332R-404A15.620
LAWD75RL36.49.215ASE16-41BD27.5L x 15D x 15.25H4.4152,9832,332R-404A9.915
LAWD100RL411.417.225ASE26-60BD41.5L x 15D x 15.25H7.0155,3774,143R-404A18.930
LAWD100RL37.011.715ASE26-60BD41.5L x 15D x 15.25H7.0155,3774,143R-404A13.420
LAWD150RL418.626.240ASE26-75BD41.5L x 15D x 15.25H7.0155,5474,313R-404A27.940
LAWD150RL311.417.225ASE26-75BD41.5L x 15D x 15.25H7.0155,5474,313R-404A18.930
LAWD200RL416.726.735BSE26-92BD45.5L x 15D x 15.25H8.7158,4387,136R-404A28.140
LAWD200RL310.218.620BSE26-92BD45.5L x 15D x 15.25H8.7158,4387,136R-404A20.030
LAWD250RL420.531.445BSE26-92BD45.5L x 15D x 15.25H8.71510,8398,674R-404A31.350
LAWD250RL312.321.225BSE26-92BD45.5L x 15D x 15.25H8.71510,8398,674R-404A20.630
LAWD250RL76.611.515BSE26-92BD45.5L x 15D x 15.25H8.71510,8398,674R-404A12.920
LASD250RL416.422.835BSE26-92BD45.5L x 15D x 15.25H8.7159,7818,480R-404A24.240
LASD250RL311.116.220BSE26-92BD45.5L x 15D x 15.25H8.7159,7818,480R-404A17.620
LASD300RL420.728.245BSE36-120BD 63.5L x 15D x 15.25H13.01511,6699,716R-404A30.650
LASD300RL313.619.330BSE36-120BD 63.5L x 15D x 15.25H13.01511,6699,716R-404A21.730
LASD350RL426.839.360BSE46-164BD 81.5L x 15D x 15.25H17.42014,48511,882R-404A42.760
LASD350RL315.024.630BSE46-164BD 81.5L x 15D x 15.25H17.42014,48511,882R-404A28.040
COMP
RLA
COND
MCA**
UNIT
C.U.
MAX
FUSE**
RACK
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
HTRS**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
LASD400RL431.845.570BSE46-185BD 81.5L x 15D x 15.25H17.42017,25814,654R-404A49.080
LASD400RL321.432.645BSE46-185BD 81.5L x 15D x 15.25H17.42017,25814,654R-404A36.050
LASD500RL323.935.750BSE56-210BE 99.5L x 15D x 15.25H18.82020,22316,969R-404A40.160
LASD500RL79.314.820BSE56-210BE 99.5L x 15D x 15.25H18.82020,22316,969R-404A19.220
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 4
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Accessible Hermetic Refrigeration Systems
-10˚F Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
20 Hour Run Time
CONDENSING UNITELECTRIC DEFROST UNIT COOLER
MODEL
NUMBER
LAAD75RL45.68.215ASE16-41BD27.5L x 15D x 15.25H4.4153,1962,699R-404A8.915
LAAD75RL33.25.215ASE16-41BD27.5L x 15D x 15.25H4.4153,1962,699R-404A5.915
LAAD100RL46.99.815ASE16-46BD27.5L x 15D x 15.25H4.4154,0923,441R-404A10.515
LAAD100RL34.66.915ASE16-46BD27.5L x 15D x 15.25H4.4154,0923,441R-404A7.615
LAAD150RL49.914.720BSE26-60BD41.5L x 15D x 15.25H7.0155,8574,624R-404A16.120
LAAD150RL36.610.615BSE26-60BD41.5L x 15D x 15.25H7.0155,8574,624R-404A12.015
LAAD200RL414.720.730BSE26-92BD45.5L x 15D x 15.25H8.7158,0737,079R-404A22.130
LAAD200RL37.411.615BSE26-92BD45.5L x 15D x 15.25H8.7158,0737,079R-404A13.020
LAAD300RL116.726.735BSE36-140BD63.5L x 15D x 15.25H13.01512,53010,578R-404A29.140
LAAD300RL312.821.825BSE36-140BD63.5L x 15D x 15.25H13.01512,53010,578R-404A24.230
LADD400RL316.825.435CSE46-185BD81.5L x 15D x 15.25H17.42017,55114,948R-404A29.140
LADD400RL78.112.515CSE46-185BD81.5L x 15D x 15.25H17.42017,55114,948R-404A15.720
LADD500RL326.337.350CSE56-210BE99.5L x 15D x 15.25H18.82021,35518,871R-404A42.060
LADD500RL710.215.220CSE56-210BE99.5L x 15D x 15.25H18.82021,35518,871R-404A17.420
LADD600RL328.840.460CSE66-245BE117.5L x 15D x 15.25H22.63024,60620,701R-404A46.170
LADD600RL710.215.220CSE66-245BE117.5L x 15D x 15.25H22.63024,60620,701R-404A22.630
LADD750RL331.543.870ESE56-210BE (2)99.5L x 15D x 15.25H 18.8 ea.20 ea.36,58330,075R-404A53.590
LADD750RL716.122.535ESE56-210BE (2)99.5L x 15D x 15.25H 18.8 ea.20 ea.36,58330,075R-404A33.540
COMP
RLA
COND
MCA**
UNIT
C.U.
MAX
FUSE**
RACK
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
HTRS**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 5
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Welded Hermetic Refrigeration Systems
-20˚F Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
20 Hour Run Time
CONDENSING UNITELECTRIC DEFROST UNIT COOLER
MODEL
NUMBER
XAWD200RL416.726.735BSE26-75BD41.5L x 15D x 15.25H 7.0155,8594,626R-404A28.140
XAWD200RL310.218.620BSE26-75BD41.5L x 15D x 15.25H7.0155,8594,626R-404A20.030
XAWD250RL420.531.445BSE26-92BD45.5L x 15D x 15.25H8.7157,6646,220R-404A33.850
XAWD250RL312.321.225BSE26-92BD45.5L x 15D x 15.25H8.7157,6646,220R-404A23.630
XAWD250RL76.611.515BSE26-92BD45.5L x 15D x 15.25H8.7157,6646,220R-404A13.920
XASD250RL416.422.835BSE26-92BD45.5L x 15D x 15.25H8.7158,0776,776R-404A24.240
XASD250RL311.116.220BSE26-92BD45.5L x 15D x 15.25H8.7158,0776,776R-404A17.620
XASD300RL420.728.245BSE36-120BD63.5L x 15D x 15.25H13.0159,6387,686R-404A30.650
XASD300RL313.619.330BSE36-120BD63.5L x 15D x 15.25H13.0159,6387,686R-404A21.730
XASD350RL426.839.360BSE36-140BD63.5L x 15D x 15.25H13.01511,5059,552R-404A41.760
XASD350RL315.024.630BSE36-140BD63.5L x 15D x 15.25H13.01511,5059,552R-404A27.040
XASD400RL431.845.570BSE46-164BD81.5L x 15D x 15.25H17.42013,90511,301R-404A49.080
XASD400RL321.432.645BSE46-164BD81.5L x 15D x 15.25H17.42013,90511,301R-404A36.050
XASD500RL323.935.750BSE46-185BD81.5L x 15D x 15.25H17.42016,50613,903R-404A39.160
XASD500RL79.314.820BSE46-185BD81.5L x 15D x 15.25H17.42016,50613,903R-404A16.220
COMP
RLA
COND
MCA**
UNIT
C.U.
RACK
MAX
FUSE**
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
HTRS**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 6
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Accessible Hermetic Refrigeration Systems
-20˚F Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
20 Hour Run Time
CONDENSING UNITELECTRIC DEFROST UNIT COOLER
MODEL
NUMBER
XAAD75RL45.68.215ASE16-36BD41.5L x 15D x 15.25H4.4152,4041,753R-404A8.915
XAAD75RL33.25.215ASE16-36BD41.5L x 15D x 15.25H4.4152,4041,753R-404A5.915
XAAD100RL46.99.815ASE16-41BD27.5L x 15D x 15.25H4.4153,0802,429R-404A10.515
XAAD100RL34.66.915ASE16-41BD27.5L x 15D x 15.25H4.4153,0802,429R-404A7.615
XAAD150RL49.914.720BSE26-60BD41.5L x 15D x 15.25H7.0154,6013,368R-404A16.120
XAAD150RL36.610.615BSE26-60BD41.5L x 15D x 15.25H7.0154,6013,368R-404A12.015
XAAD200RL414.720.730BSE26-75BD41.5L x 15D x 15.25H7.0156,0104,777R-404A22.130
XAAD200RL37.411.615BSE26-75BD41.5L x 15D x 15.25H7.0156,0104,777R-404A13.020
XAAD300RL416.726.735BSE36-120BD45.5L x 15D x 15.25H13.0159,0577,105R-404A29.140
XAAD300RL312.821.825BSE36-120BD45.5L x 15D x 15.25H13.0159,0567,105R-404A24.230
XADD400RL316.825.435CSE46-164BD81.5L x 15D x 15.25H17.42013,42310,820R-404A29.140
XADD400RL78.112.515CSE46-164BD81.5L x 15D x 15.25H17.42013,42310,820R-404A17.420
XADD500RL326.337.350CSE46-185BD81.5L x 15D x 15.25H17.42016,36413,761R-404A41.060
XADD500RL710.215.220CSE46-185BD81.5L x 15D x 15.25H17.42016,36413,761R-404A17.420
XADD600RL328.840.460CSE56-210BD99.5L x 15D x 15.25H18.82018,97815,724R-404A46.170
XADD600RL710.215.220CSE56-210BD99.5L x 15D x 15.25H18.82018,97815,724R-404A18.820
COMP
RLA
COND
MCA**
UNIT
C.U.
MAX
FUSE**
RACK
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
HTRS**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
XADD750RL331.543.870ESE46-185BD (2)81.5L x 15D x 15.25H 17.4 ea.20 ea.28,75323,547R-404A53.580
XADD750RL716.122.535ESE46-185BD (2)81.5L x 15D x 15.25H 17.4 ea.20 ea.28,75323,547R-404A27.240
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 7
Remote Refrigeration Rack
"Y"
CONNECTIONS THIS END
ELECTRICAL & REFRIGERATION
"Y"
END VIEWTOP VIEW
AIR FLOW
"Z"
"X"
RackDimension "X" Dimension "Y" Dimension "Z"
Rack "A"19" High26-1/4" Wide35-3/4" Deep
Rack "B"22" High36-1/8" Wide37" Deep
Rack "C"34" High31-7/8" Wide56-7/8" Deep
Rack "CC"34" High46-3/8" Wide49-3/8" Deep
Rack "D"44" High66-5/8" Wide54-1/8" Deep
Rack "E"41-1/4" High42-1/4" Wide58-1/8" Deep
Rack "S"25" High36-1/8" Wide49-1/2" Deep
Dimensions Include Optional Hood
WITH OPTIONAL LEGS, ADD 4"
TO DIMENSION "X".
Air Cooled, Accessible Hermetic Refrigeration Systems
35˚ Operating Temperature -- 100˚F Ambient Temperature
Condensing Unit/Unit Cooler Balance
16 Hour Run Time
CONDENSING UNITUNIT COOLER
MODEL
NUMBER
NAAD50RL43.75.715ASA18-41BA27.5L x 15D x 15.25H1.0153,8823,461R-404A6.715
NAAD50RL32.23.715ASA18-41BA27.5L x 15D x 15.25H1.0153,8823,461R-404A4.715
NAAD75RL45.47.930ASA18-53BA27.5L x 15D x 15.25H1.0155,2154,785R-404A8.915
NAAD75RL33.04.915ASA18-53BA27.5L x 15D x 15.25H1.0155,2154,785R-404A5.915
NAAD100RL47.49.815ASA28-76BA41.5L x 15D x 15.25H2.0157,3906,549R-404A11.820
NAAD100RL34.36.515ASA28-76BA41.5L x 15D x 15.25H2.0157,3906,549R-404A8.515
NAAD150RL47.511.115BSA28-106BA45.5L x 15D x 15.25H2.0159,3768,535R-404A13.120
NAAD150RL34.37.715BSA28-106BA45.5L x 15D x 15.25H2.0159,3768,535R-404A9.715
NAAD200RL110.615.620BSA28-134BA45.5L x 15D x 15.25H2.01513,46212,621R-404A17.620
NAAD200RL36.810.815BSA28-134BA45.5L x 15D x 15.25H2.01513,46212,621R-404A12.815
NAAD300RL312.421.325BSA48-264BA81.5L x 15D x 15.25H4.01523,43921,756R-404A25.350
NAAD300RL75.810.515BSA48-264BA81.5L x 15D x 15.25H4.01523,43921,756R-404A14.520
NADD500RL322.332.350CSA68-390BA117.5L x 15D x 15.25H6.01536,70534,181R-404A38.350
NADD500RL710.415.420CSA68-390BA117.5L x 15D x 15.25H6.01536,70534,181R-404A21.425
NADD750RL332.045.770ESA68-318BA (2)117.5L x 15D x 15.25H6.01561,67456,626R-404A57.770
NADD750RL714.120.630ESA68-318BA (2)117.5L x 15D x 15.25H6.01561,67456,626R-404A32.640
COMP
RLA
COND
MCA**
UNIT
C.U.
MAX
FUSE**
RACK
SIZE
MODEL
NUMBER
SIZE
COIL
MCA**
COIL
MAX
FUSE**
UNADJUSTED
BTU/HOUR
AVAILABLE
BTU/HOUR
REFRIG
SYSTEM
MCA
SYSTEM
MAX
FUSE
**USE MCA & MAX FUSE VALUES FOR 2 PT ELECTRICAL CONNECTIONS SINGLE POINT ELECTRICAL DATA
Page 8
Room Temperature
N = 38˚/35˚F
F = 0˚F
L = -10˚F
X = -20˚F
A = Air Cooled
W = Water cooled
Condensing Unit Body
A = Accessible Hermetic
W = Welded Hermetic
D = Discus
S = Scroll
Refrigerant
D = R-404A
System Size*
50 Series
75 Series
100 Series
125 Series
150 Series
200 Series
225 Series
250 Series
300 Series
325 Series
350 Series
400 Series
500 Series
600 Series
700 Series
750 Series
1000 Series
REMOTE REFRIGERATION MODEL NUMBER NOMENCLATURE
NDWA100RL3-______
OPTIONS
W = All Weather Hood
A = 0˚F & up Ambient Control Kit
B = 0˚F to -20˚F Ambient Control Kit
C = -20˚F to -45˚F Ambient Control Kit
E = Electrical Defrost on Normal Temperature
System
V = Vibrasorber (Suction Line)
T = Timer Defrost on Normal Temperature
System
1 = 5' Precharged Lines
2 = 10' Precharged Lines
3 = 15' Precharged Lines
4 = 20' Precharged Lines
5 = 25' Precharged Lines
6 = 30' Precharged Lines
7 = 35' Precharged Lines
8 = 40' Precharged Lines
9 = 45' Precharged Lines
0 = 50' Precharged Lines
R = Crankcase Pressure Relief Valve
X = Pressure Relief Valve
Y = Prepiped (includes liquid line drier, sight
glass & hand valve installed on rack)
P = Prewired (condensing unit/unit cooler
interwired)
Z = Fused Disconnect
R = Remote System* Not all system sizes are available in all
condensing unit bodies. Consult Factory for specic
availabilities.
General:
Condensing units shall be accessible hermetic or welded hermetic with air cooled or optional water cooled condenser. Condensing units shall be factory assembled and UL
listed. Evaporators shall be forced air type designed for ceiling installation. Air discharge shall be parallel to the walk-in ceiling. Fan motors, guards, multi-n and tube-type coil
shall be housed in heavy gauge aluminum housing. Unit shall have drain pan with suitable drain pipe connection. Freezer evaporators shall have an automatic electric defrost
system including heaters, time clock, defrost end and fan delay control and heated drain pan. Defrost shall be time initiated and temperature terminated with built-in fail-safe
control. All cooler systems are equipped with an "off cycle" timer to maximize heat transfer and maintain optimum energy efciency. Evaporators shall be U.L. listed and be
available in Lo Prole design.
Split-Pak™ Pre-Assembled Remote Systems:
Pre-assembled systems shall be furnished for remote condensing unit installations using the basic components described under the general section. Condensing unit shall be
factory mounted to a galvanized steel rack. Rack is to include a control box enclosing factory pre-wired pressure controls and contactor for three phase units. Optional condens-
ing unit housing and low ambient controls for the specic application shall be factory installed. Liquid line lter drier, sight glass, expansion valve and temperature control shall
be factory installed. A time clock housed in an enclosure shall be provided loose, for eld installation. The systems shall be designed to require no evaporator/condensing unit
inter-wiring. Field provided two point electrical connection and refrigerant piping shall be required. Optional pre-charged systems and Line sets shall be available up to 300 Series
and up to 50 ft. maximum length using quick connect refrigerant line ttings.
Specications subject to change.
NOR-LAKE, INCORPORATED
727 Second Street
Hudson, Wisconsin 54016
800-955-5253
715-386-2323
800-961-5253 PARTS
800-388-5253 SERVICE
715-386-4291 FAX
www.norlake.com
101500 5/10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.