Tankless Water Heater Accessories
Specification Sheet
Quick Connect Cord
• Connects two identical water heater models together in
order to get twice the output of hot water
• Provides a communication link and rotates the operation
between the two units evenly
• Simple installation, just attach the cord to the proper
connectors inside each water heater
• Compatible with larger Residential models and ALL
Commercial models (see Compatibility Chart below)
Dimensions
(Connector wiring colors)
Example Installation
6 ft.
Connector Cable
(Connector wiring colors)
Quick Connect Cord
Quick Connect Cord (#QC-1)
Quick Connect Cord (#QC-2)
Models Compatible with QC-1
NR98 Series
NC199 Series
NCC199 Series
NRC111 Series
Models Compatible with QC-2
NRC83 Series
NRC98 Series
NR50 Series
NR83 Series
NR981 Series
NRC1111 Series
NC1991 Series
NCC1991 Series
NR111 Series
NC250 Series
NC380 Series
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Rev. 5/12
Quick Connect Multi System Installation
• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
The Quick Connect Cord is 6 ft. long. Install the units 2-18" apart from each other to ensure the
cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the dierence in pipe length
between the two units).
System Diagram
Quick Connect
Cord
Cord
Connector
Typical Plumbing
Cord
Connector
Terminal Block
Remote Controller
Remote Controller Cord
G
Distance at center: 16-32 in.
Distance on sides
2-18 in.
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
Gas Supply Piping
Cold Water Supply
Hot Water
Union
Union
Gas Valve
Shutoff Valve
Shutoff
Valve
Hot Water
Cold Water
Size the piping to allow for the maximum
flow rates of the units.
Make this distance as short as possible.
* The hot water temperature will
become unstable as the pipe
length increases.
Union
Quick Connect
cord
Pressure
Relief
Valve
Shutoff
Valve
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold
water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold
temperatures.