Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER indicates an imminently hazardous situation which,
DANGER
if not avoided, will result in death or serious injury.
WARNING
CAUTION
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Disconnect
Power
Ground
Be sure to do
CAUTION
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
•
After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
SAR8563-6
Rev. 08/08
CERTIFIED
R
Low NOx
Approved by
SCAQMD
Accepted For Use
City of New York
Department of Buildings
MEA 19-03-E
FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED
HOME APPLICATIONS.
I
nstallation must conform with local codes, or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).
When applicable, installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the
Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86.
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
*SAR8563 C*
1.
Included Accessories
The following accessories are included with the unit.
Check for any missing items before starting installation.
PartShapeQ’ty
Tapping Screw
Remote Controller
(See p. 20)
2.
Optional Accessories
Flue Terminal
VT4-TL
Flue Terminal
VT4-TS
5
1
1
1
Owner's Guide, Warranty,
Installation Manual
(this document)
Remote Controller
Cord (10ft)
The accessories listed below are not
included with the units, but may be necessary
for installation.
Quick Connect
Cord
Remote Controller
Cord (26 ft)
Q’tyShapePart
1
each
1
Q’tyShapePartPartShapeQ’ty
1
1
Isolation Valves
(includes pressure
relief valve)
1
Pipe Cover
(PC-3S)
1
2
3.
Quick Connect Multi System Installation
• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
The Quick Connect Cord is 6 ft. long. Install the units 2-19" apart from each other to ensure the
cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).
System Diagram
Quick Connect
Cord
Cord
Connector
Typical Plumbing
Cord
Connector
Terminal Block
Remote Controller
Remote Controller Cord
G
Distance at center: 20.3-37.4".
Distance on sides
2-19".
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
Gas Supply Piping
Cold Water Supply
Hot Water
Union
Union
Gas Valve
Shutoff Valve
Shutoff
Valve
Hot Water
Cold Water
Size the piping to allow for the maximum
flow rates of the units.
Make this distance as short as possible.
* The hot water temperature will
become unstable as the pipe
length increases.
Union
Quick Connect
Cord
Pressure
Relief
Valve
Shutoff
Valve
Leave enough clearance around the plumbing
to apply insulation. It will be necessary to add
bends to the piping to ensure that this
clearance is available.
• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold
water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold
temperatures.
3
Before Installation
199,900 BTU
12,000 BTU
202
0.65
3.3
765
15
150
N-0751M-D
4.
DANGER
Checkup
• Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
WARNING
Precautions on Vent Pipe Replacement
• The vent system will almost certainly need to be replaced when this appliance is being installed.
Use vent pipe that is listed to UL 1738 for Category III appliances for the exhaust venting. Category
III listed vent pipe is suggested for the air supply pipe also, but other materials may be acceptable.
Consult local codes.
* If Category III listed vent pipe is already installed, check for punctures, cracks or blockages and
consult with the vent pipe manufacturer before reusing.
Use Approved Vent Materials
• Use only vent materials that are listed to UL 1738 for Category III appliances for the exhaust venting
of this appliance.
Improper venting may result in fires, property damage or exposure to Carbon Monoxide.
Snow Precaution
• If this product will be installed in an area where snow is known to accumulate, protect the vent
termination from blockage by snow drifts or damage from snow falling off of roofs.
Check the Gas
• Check that the rating plate indicates the
N-0751M-D
correct type of gas.
• Check that the gas supply line is sized for
199,900 Btuh for this unit.
V
199,900 BTU
12,000 BTU
202
765
0.65
3.3
150
15
2
Check the Power
• The power supply required is 120VAC, at 60Hz.
May result in fire or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
• Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
CAUTION
Do Not Use Equipment for Purposes Other Than Those Specified
• Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
• If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
4
Choosing Installation Site
5.
* Locate the appliance in an area where leakage from the unit or connections will not result in damage
to the area adjacent to the appliance or to the lower floors of the structure. When such locations
cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict combustion air flow.
DANGER
• Locate the vent terminal so that there are no obstacles around the termination and so that exhaust can't accumulate. Do not enclose the termination with corrugated metal or other materials.
WARNING
• Avoid places where fires are common, such as those where gasoline,
benzene and adhesives are handled, or places in which corrosive gases
(ammonia, chlorine, sulfur, ethylene compounds, acids) are present.
Using the incorrect voltage may result in fire or cracking.
• Avoid installation in places where dust or debris will accumulate.
Dust may block the air-supply opening, causing the performance of the
device fan to drop and incomplete combustion to occur as a result.
Prohibited
• Avoid installation in places where special chemical agents
(e.g., hair spray or spray detergent) are used.
Ignition failures and malfunction may occur as a result.
• Carbon Monoxide Poisoning Hazard. Do not install this water heater in a
recreational vehicle or on a boat.
CAUTION
• The water heater is designed for indoor installation only. Never install it
outdoors or in a bathroom, it may be damaged or a fire may be caused.
• Consult with the customer concerning the location of installation.
• Install the water heater in an area that allows for the proper clearances
to combustible and noncombustible construction. Consult the rating
plate on the appliance for proper clearances.
• Do not install the water heater in a place where it may be threatened by
falling objects, such as under shelves.
• The water heater must be installed in a place where supply and exhaust
pipes can be installed as directed.
• Do not install the water heater where the exhaust will blow on outer
walls or material not resistant to heat. Also consider the surrounding
trees and animals.
The heat and moisture from the water heater may cause discoloration of
walls and resinous materials, or corrosion of aluminum materials.
Prohibited
5
CAUTION
• Avoid installation above gas ranges or stoves.
• Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.
• Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neighbors.
Prohibited
• Before installing, make sure that the exhaust flue termination will
have the proper clearances according to the National Fuel Gas
Code (ANSI Z223.1).
State of California: The water heater must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.
The Commonwealth of Massachusetts: The water heaters can be used for domestic hot water or space
heating systems, not in a combination of domestic and space heating.
For Venting Manufacturers Requirements, see websites or phone numbers listed below:
Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI
Z223.1/NFPA 54 – latest edition. In Canada, see NSCNGPIC for detailed requirements.
Item
• Maintain the following clearances
from both combustible and
non-combustible materials.
Distance from combustibles
• If possible, leave 8" or more on either
side of the unit to facilitate inspection.
• If possible, leave 24" or more in front of
the unit to facilitate maintenance
and service if necessary.
• If possible, leave 3" or more above and
below the vent pipe to facilitate inspec-
repair/inspection
tion and repair if necessary
Securing of space for
CheckIllustration
2" or
more
Distance from
the side
8" or
more
8" or
more
24" or
more
12"
or
more
4" or
more
3"
3"
or more
or more
• There must be a clearance of 24" or
more in front of the Flue terminal.
• This restriction will not be applied to an
area where an effective shield makes a
clearance of 24" or more in front of the
exhaust outlet.
into Any Building
Outdoor Clearances to Opening
There must be no
building opening
within this area.
12"
or more
12" or
more
12" or
more
Flue terminal
12" or
more
7
Clearance Requirements from Vent Terminations to Building Openings
* All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code,
ANSI Z223.1 and in Canada, in accordance with NSCNGPIC.
Clearance
Above grade, veranda, porch, deck,
A=
or balcony
Window or door that may be opened
B=
Permanently closed window
C=
Vertical clearance to ventilated soffit
located above the terminal within a
D=
horizontal distance of 2 feet from the
center of the terminal
Unventilated soffit
E=
Outside corner
F=
Inside corner
G=
Each side of center line extended
H=
above meter/regulator assembly
Service regulator vent outlet
I=
Nonmechanical air supply inlet or
J=
combustion air inlet to any other
appliance
Mechanical air supply inlet
K=
Above paved sidewalk or paved
L=
driveway located on public property
Under veranda, porch, deck, or
M=
balcony
Vent Terminal
Air Supply Inlet
12" (12")
12" (36")
*
*
*
*
*
3' within a height 15' above
meter/regulator assembly
3'
12" (36")
3' above if within 10' (6')
(7' ***)
* (12"- Canada Only****)
Area Where Terminal
is Not Permitted
()= indicates clearances required in Canada
*Maintain clearances in accordance with local installation codes and the requirements of the gas supplier
***A vent shall not terminate directly above a sidewalk or paved driveway that is located between two
single family dwellings and serves both dwellings.
****Permitted only if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor.
7. Installation
Securing to the wall
8
Be sure to do
• The weight of the device will be applied to the wall. If the strength of the wall is not sufficient, reinforcement must be done to prevent the transfer of vibration.
• Do not drop or apply unnecessary force to the device when installing. Internal parts may
be damaged and may become highly dangerous.
• Install the unit on a vertical wall and ensure that it is level.
Item
CAUTION
• When installing with bare hands, take caution to
not inflict injury.
• Be careful not to hit electrical wiring, gas, or water
piping while drilling holes.
1. Drill a single screw hole, making sure to hit a stud.
2. Insert and tighten the screw and hang the unit by
the upper wall mounting bracket.
Locating Screw Holes
3. Determine the positions for the remaining four screws
(two for the top bracket and two for the bottom), and
remove the unit.
4. Drill holes for the remaining four screws.
5. Hang the unit again by the first screw, and then
insert and tighten the remaining four screws.
6. Take waterproofing measures so that water does
not enter the building from screws mounting the
Mounting
device.
IllustrationCheck
Location of Screw Hole
Mounting Bracket
(upper)
Locating Screw Holes
Tapping Screw
• Make sure the unit is installed securely so that it will
not fall or move due to vibrations or earthquakes.
Structure
• If this water heater is being installed at an elevation of 2,000
ft. (610m) or higher, disconnect the connector labeled "High
Elevation Disconnect" as illustrated on the right. This connector is located inside the unit.
• Disconnect power to the water heater before disconnecting
this connector. Failure to perform this step will result in a
"73" code displayed on the remote controller and a cease in
Above 2,000 ft.
operation. If this occurs, disconnect, then reconnect power
to the water heater to reset the system.
Installations at Elevations
Vent Pipe Installation
8.
(Indoor Installation Only)
DISCONNECT
HIGH ELEVATION
Vent Terminal Installation
• Follow the installation instructions included with the vent terminal. It is suggested that the appliance be
vented horizontally through a sidewall. If a vertical vent termination is required, it must follow the
requirements of this section (p.9-12).
9