Noritz CB199-DV User Manual

Model CB199 and CB180 Series
Residential Condensing Gas Combination Boiler
Specification Sheet
• Standard Input- Gas consumption ranges:
CB199 : 18,000 BTUh to 199,000 BTUh CB180 : 18,000 BTUh to 180,000 BTUh
• Heating Mode Input- Gas consumption ranges:
CB199 : 18,000 BTUh to 120,000 BTUh CB180 : 18,000 BTUh to 100,000 BTUh
• Turndown Ratio- 6.7 (CB199) and 5.6 (CB180)
• Capacity Range- Flow rates of 0.5 GPM up to 9.3 GPM (CB199) and 9.1 GPM (CB180)
• Compact Design- ANSI A21.13/CSA 4.9 certified design that can be wall-mounted
indoors
• Durable Steel Casing with Polyester Coating
• Heat Exchanger- Manufactured with STS 304 stainless steel
• Venting Options- For indoor installation only. Convertible to Single Vent (-SV) with
the use of conversion kit (#SV-CK-3)
• Direct Electronic Ignition
DV Model
• AFUE- 0.95(NG) 0.95(LP)
• Temperature Controls- Includes remote thermostat that can precisely adjust the
output temperature with the capability to display temperatures in °C; Domestic Mode: 90°F to 140°F, Heating Mode: 100°F to 180°F
• Outdoor Reset Control- Built-in customizable programming for Energy Savings and Comfort with Outdoor Temperature Sensor (included)
• Power Cord Installation Kit- 6’ power cord is included
• Safety Devices- Flame Sensor, Overheat Cut off Limit Switch, Gas Leak Detector
Sensor, Water Leak Detector Sensor, Exhaust Temperature Sensor, Pressure Sensor, Heating Supply Temperature Sensor
• Internal Pump- Heating Mode: used for primary closed loop. Domestic Mode: used for pre-heating of internal plate heat exchanger
• 10-Year* Limited Heat Exchanger Warranty for Residential Use
• 5-Year Limited Parts Warranty
CB199-DV CB180-DV
3” PVC Termination (#VK3-H-PVC)
Vertical Adapter Set (#VK3-PVC-VAS)
PVC Terminal (#PRC-1)
Horizontal Hood Termination (#PVT-HL)
Isolation Valves (# IK-WV-200-1)
Vent Screens with Finishing (2”) (After Market)
PVC Reducer Bushing (3in X 2in) (After Market)
SV Conversion Kit (#SV-CK-3) 90 Elbow with Inlet Screen
*Primary Heat Exchanger warranty is maintained at 10 years when used in a single family dwelling and 3 years when product is supplied with pre-heated or circulated water on the domestic water side, in accordance with the Installation Manual. Refer to Noritz Limited Warranty for complete coverage details.
** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fount ain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
28.7" [730mm]
Dimensions
Flow Rates
Temperature Rise (°F)
Flow Rate
GPM)
(
CB199-DV
CB180-DV
30 40 45 50 60 70 80 90 100
7.7 7.0 5.8 4.9 4.3 3.89.3 8.6 3.2
9.1 8.3 7.2 6.5 5.4 4.6 4.0 3.6 3.2
70
60
50
40
30
Water Pressure (psi)
20
10
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
DHW Pressure Loss
Flow Rate (GPM)
Specifications
Model Name
Weight
Operating Pressure
Gas Supply Pressure
Water Holding Capacity
Water Inlet
Hot Water Outlet
r
erature
Gas Inlet
Condensate Drain
Auto Feeder Inlet Heating Supply Heating Return
Supply
Domestic Hot Water
Heating
°F Mode
°C Mode
°F Mode
°C Mode
Connection Sizes
Powe
Freeze Protection
Temp
Settings
CB199-DV
187W(71W+116W_PUMP)Consumption
90 (pounds)
15 - 150 psi
NG: 3.5” - 10.5” LP: 8.0” - 14.0”
Under 2 Gallons
3/4"
3/4"
3/4"
1/2" Threaded
3/4"
1" 1"
120VAC 60Hz
42°F (5.5°C) - 46°F (8°C)
Normal Temp: 90-120°F, High Temp : 121-140°F (In 1°F intervals)
Normal Temp: 32-49°C, High Temp : 49.5-60°C (In 1°C intervals)
100-180°F
38-82°C
CB180-DV
180W(64W+116W_PUMP)
ut notice.
Rev.
01/16