VALVES
Norgren.com/usa – 303.794.2611 – help@amer.norgren.com
VAL-76
V40/V41 Mini ISO Star Valves
2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO 15407-1 / VDMA 24 563 Size 18 mm
Model Spool Operator Return Flow Operating Pres. Pilot Pres. Weight Repair Kit
Techn. 14 12 Cv (psig) (psig) (lb.)
V405537A-X0090 Gl Air Spring 0.58 26" Hg - 232 23.2 - 232 0.24 V70440-K5O
V415537A-X0090 Ss Air Spring 0.66 26" Hg - 145 29 - 145 0.22 V70442-K5O
V405533A-X0020 Gl Air Air 0.58 26" Hg - 232 29 - 232 0.24 V70441-K5O
V415533A-X0020 Ss Air Air 0.66 26" Hg - 145 29 - 145 0.24 V70443-K5O
V405533A-X0020 Gl Air (priority) Air 0.58 26" Hg - 232 29 - 232 0.24 V70441-K5O
Model Function Actuation Flow Operating Pres. Pilot Pres. Weight Spares Kit
2x3/2 3/2 Function Cv (psig) (psig) (lb.)
V415A33A-X0020 NC Air/Spring 0.62 0 - 145 24.7 + (0.35 x op. pressure) 0.26 V70447-K5O
V415B33A-X0020 NO Air/Spring 0.62 0 - 145 24.7 + (0.35 x op. pressure) 0.26 V70448-K5O
V415C33A-X0020 NO/NC Air/Spring 0.62 0 - 145 24.7 + (0.35 x op. pressure) 0.26 V70449-K5O
2x3/2 Air Pilot Actuated Valves (Softseal Spool)
5/2 Air Pilot Actuated Valves
5 1 3
4 2
10
10
12
14
5 1 3
4 2
14
12
1010
5 1 3
4 2
10
12
1014
4 2
14
12
35
1
4
2
14
12
35
1
4
2
14
12
35
1
Model Spool Valve Pilot Pilot Operator Return Flow Operating Pilot Pres. Weight Repair Kit
Techn. Function Supply Exhaust 14 12 Cv Pres. (psig) (psig) lb.
V405611D-C3**† Gl APB Internal Collected Solenoid Solenoid 0.62 29 - 145 - 0.40 V70441-K5O
V415611D-C3**† Ss APB Internal Collected Solenoid Solenoid 0.69 29 - 145 - 0.40 V70444-K5O
V405622D-C3**† Gl APB External Not collected Solenoid Solenoid 0.62 26" Hg - 232 29 - 145 0.40 V70441-K5O
V415622D-C3**† Ss APB External Not collected Solenoid Solenoid 0.69 26" Hg - 145 29 - 145 0.40 V70444-K5O
V405711D-C3**† Gl COE Internal Collected Solenoid Solenoid 0.62 29 - 145 - 0.40 V70441-K5O
V415711D-C**† Ss COE Internal Collected Solenoid Solenoid 0.69 29 - 145 - 0.40 V70441-K5O
V405722D-C3**† Gl COE External Not collected Solenoid Solenoid 0.62 26" Hg - 232 29 - 145 0.40 V70441-K5O
V415722D-C3**† Ss COE External Not collected Solenoid Solenoid 0.69 26" Hg - 145 29 - 145 0.40 V70445-K5O
V405811D-C3**† Gl COP Internal Collected Solenoid Solenoid 0.62 29 - 145 - 0.40 V70441-K50
V415811D-C3**† Ss COP Internal Collected Solenoid Solenoid 0.69 29 - 145 - 0.40 V70446-K5O
V404822D-C3**† Gl COP External Not collected Solenoid Solenoid 0.62 26" Hg - 232 29 - 145 0.40 V70441-K5O
V415822D-C3**† Ss COP External Not collected Solenoid Solenoid 0.69 26" Hg - 145 29 - 145 0.40 V70446-K5O
5/3 Solenoid Pilot Actuated Valves
4
2
12
14
35
1
84
82
4 2
12
14
35
1
84
82
4
2
12
14
35
1
84
82
4
2
12
14
14351
84
82
4 2
12
14
14351
84
82
4
2
12
14
14351
84
82
Table 1
**Voltage Codes and Spare Pilot Valves
Voltage Code Power Inrush / Hold Pilot Valve Part.-no.
12 V d.c. 12 1.2 W VZC7L2C1-C312A
24 V d.c. 13 1.2 W VZC7L2C1-C313A
24 V 50/60 Hz. 14 2.1 / 1.5 VA VZC7L2C1-C314A
48 V 50/60 Hz 16 2.1 / 1.5 VA VZC7L2C1-C316A
110 V d.c. 17 1 W VZC7L2C1-C317A
115 V 50/60 Hz 18 2.1 / 1.5 VA VZC7L2C1-C318A
230 V 50/60 Hz 19 2.1 / 1.5 VA VZC7L2C1-C319A
Other voltages available on request.
Spare pilot valves are delivered with mounting screws.
Table 2
†Connector Codes and Part Number
Code Part Number
A = Solenoid without connector
B = Cable grip V10027-D00
C = 10 ft. molded cable, 0-240 VAC/VDC V10013-D03
H = Cable grip w/indicator light, 24 VAC/VDC V10012-D13
J = Cable grip w/indicator light, 120 VAC/VDC V10012-D18
5 = 10 ft. molded cable with indicator light, surge suppression, 24 VAC/VDC V10014-D03
6 = 10 ft. molded cable with indicator light, 110V/50 Hz-120V.60Hz V10015-D03
** Insert voltage code from Table 1 “Voltage Codes and Spare Pilot Valves”.
† Add connector code from Table 2 “Connector Codes and Part Number”.