Norgren R06 User Manual

See Section ALE-24 for Accessories
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-5-2
R06
Compact design, corrosion resistant construction
Brass body with choice of plastic or brass bonnet
Plastic bonnet equipped with low torque, non-rising
Brass bonnet equipped with pressure adjusting
screw
Non-relieving models for air and water service
Relieving models for air service allow reduction of
outlet pressure even when the system is dead-ended
Can be disassembled without the use of tools or
removal from the air or water line
Miniature Brass Body Regulator
Water and Compressed Air Service
1/8" and 1/4" PTF Port Sizes
ISO Symbols
Relieving Non relieving
Alternative Models
0R 6
★ ★ ★ ★
-
★ ★
-
Port Size Substitute 1/8" 1 1/4" 2
Threads Substitute PTF A
Outlet Pressure Adjustment Range† Substitute 1 to 10 psig (0.1 to 0.7 bar) A 5 to 50 psig (0.3 to 3.5 bar) E 5 to 100 psig (0.3 to 7 bar) K 5 to 125 psig (0.3 to 8.6 bar) L
Gauges Substitute With G Without N
Diaphragm Substitute Relieving R Non relieving N
Bonnet Substitute Plastic 21 Brass 22
† Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.Do not use these units to control pressures outside of the specified ranges.
Ordering Information.Models listed include PTF threads, plastic bonnet with knob adjustment, non-relieving diaphragm, 5to 100 psig (0.3 to 7 bar)
outlet pressure adjustment range†, and without gauge.
Port Model Flow*scfm (dm3/s) Flow**gpm (lpm) Weight lb (kg) 1/8" PTF R06-121-NNKA 12 (5.7) 1.3 (4.9) 0.2 (0.09) 1/4" PTF R06-221-NNKA 12 (5.7) 1.3 (4.9) 0.2 (0.09)
* Approximate flow with 100 psig (7 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set. ** Approximate flow with100 psig ( 7 bar) inlet pressure, 60 psig (4 bar) set pressure and a 15 psig (1 bar) droop from set.
ALE-5-3
All Dimensions in Inches (mm)
Littleton, CO USA Phone 303-794-2611 www.norgren.com
R06 Special Purpose Regulators
Technical Data
Fluid: Water and compressed air Maximum pressure: 400 psig (27 bar) Operating temperature
Water service: 35° to 150°F (2° to 65°C)† Air service: -30° to 150°F (-34° to 65°C) *†
* Air supply must be dry enough to avoid ice formation at temperatures
below 35°F (2°C).
Typical flow for water service at 100 psig (7 bar) inlet pressure, 60 psig (4 bar) set
pressure and a droop of 15 psig (1 bar) from set: 1.3 gpm (4.9 lpm)
Typical flow for compressed air service at 100 psig (7 bar) inlet pressure, 90 psig
(6.3 bar) set pressure and a droop of 15 psig (1 bar) from set: 12 scfm (5.7 dm
3
/s) Gauge ports: 1/8" PTF Materials
Body: Brass Bonnet
Standard: Acetal resin
Optional: Brass Valve: Brass/nitrile Valve seat: Acetal resin Elastomers: Nitrile
PORT SIZE 1/8" SPRING RANGE: 5 to 100 psig (0.3 to 7 bar) INLET PRESSURE: 100 psig (7 bar)
WATER FLOW CHARACTERISTICS
0 2 4 6 8 10 litres/min
WATER FLOW
0 0.5 1.0 1.5 2.0 2.5 US gal./min
OUTLET PRESSURE
8
6
4
2
0
bar
100
80
60
40
20
0
psig
PORT SIZE: 1/8" SPRING RANGE: 5 to 100 psig (0.3 to 7 bar) INLET PRESSURE: 100 psig (7 bar)
AIR FLOW CHARACTERISTICS
024 6810dm
3
/s
AIR FLOW
0 4 8 12 16 20 scfm
OUTLET PRESSURE
8
6
4
2
0
bar
100
80
60
40
20
0
psig
Typical Performance Characteristics
0.91
(23)
2.46 (63)
2.86 (73)
1.1 (28)
1.03 (26)
3.01 (77)
3.41 (87)
Models with Plastic Bonnet
Models with Brass Bonnet
1.50 (38)
1.50 (38)
1.50 (38)
1.50 (38)
2.13 (54)
1.57 (40)
2.13 (54)
1.57 (40)
Panel mounting hole diameter:
Models with plastic bonnet: 1.19" (30 mm) Models with brass bonnet: 0.81" (21mm)
Maximum panel thickness:0.25" (6 mm)
Service Kits
Item Type Part number Service kit
Relieving 3407-18 Non relieving 3407-17
Service kit includes slip ring, diaphragm, standard valve seat with o-ring, valve, valve spring.
† Brass bonnet & body combination max temperature 200°F
Loading...