Norgren N17 User Manual

R17
Installation & Maintenance
Instructions
DISASSEMBLY
1. Regulator can be disassembled without removal from air line.
2. Shut off inlet pressure. Reduce pressure in inlet and outlet lines to zero.
3. Turn adjustment (1 or 3) fully counterclockwise to remove all force on regulating spring (7).
4. Disassemble in general accordance with the item numbers on exploded view.
CLEANING
1. Clean parts with warm water and soap. Do not submerge knob type bonnets (1) in solution, as lubricant will be removed.
2. Rinse and dry parts. Blow out internal passages in body with clean, dry compressed air.
3. Inspect parts. Replace those found to be damaged.
ASSEMBLY
1. Lubricate o-rings, valve stem (15), valve bore in bottom plug (12), adjusting screw tip and adjusting screw threads inside bonnet (1, 6), threads on bonnets (1, 6) and bottom plug (12) with a light coat of good quality o-ring grease.
2. Assemble the unit as shown on the exploded view.
3. Torque Table Item Torque in Nm (Foot-Pounds) 1, 6 (Bonnets) 41 to 48 (30 to 35) 12 (Bottom plug) Hand tight
WARNING
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data.
If outlet pressure in excess of the regulator pressure setting could cause downstream equipment to rupture or malfunction, install a pressure relief device downstream of the regulator. The relief pressure and flow capacity of the relief device must satisfy system requirements.
The accuracy of the indication of pressure gauges can change, both during shipment (despite care in packaging) and during the service life. If a pressure gauge is to be used with these products and if inaccurate indications may be hazardous to personnel or property, the gauge should be calibrated before initial installation and at regular intervals during use.
Before using these products with fluids other than air, for non industrial applications, or for life-support systems consult Norgren.
TECHNICAL DATA
Fluid: Compressed air Maximum pressure: 20 bar (300 psig) Operating temperature: -34° to +80°C (-30° to +175°F) * Air supply must be dry enough to avoid ice formation at
temperatures +2°C (+35°F). Typical flow at 10 bar (150 psig) inlet pressure, 6,3 bar (90 psig) set pressure, and a droop of 1 bar (15 psig) from set: 227 dm
3
/s (480 scfm)
Gauge ports:
1/4" PTF with PTF main ports
Rc1/4 with ISO Rc and ISO G main ports Materials:
Body: Aluminum Bonnet: Aluminum Bottom plug: Acetal Valve: Aluminum and nylon Elastomers: Nitrile
REPLACEMENT ITEMS
Service kit (includes items circled on exploded view)
Relieving...............................................................5578-02
Non-relieving........................................................5578-01
Tamper resistant seal wire .......................................2117-01
PANEL MOUNTING DIMENSIONS
Panel mounting hole diameter: 58 mm (2.28") Panel thickness: 2 to 4 mm (0.06" to 0.16")
INSTALLATION
1. Shut off air pressure. Install regulator in air line -
with air flow in direction of arrow on body,
upstream of lubricators and cycling valves,
as close as possible to the device being serviced.
at any angle.
2. Connect piping to proper ports using pipe thread sealant
on male threads only. Do not allow sealant to enter interior of regulator.
3.
Install a pressure gauge or plug the gauge ports. Gauge ports can also be used as additional outlets for regulated air.
4. Install a Norgren general purpose filter upstream of the
regulator.
ADJUSTMENT
1. Before applying inlet pressure to regulator, turn
adjustment (1 or 3) counterclockwise to remove all force on regulating spring (7).
2. Apply inlet pressure, then turn adjustment (1 or 3)
clockwise to increase and counterclockwise to decrease pressure setting.
3. Always approach the desired pressure from a lower
pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than that desired, then bring up to the desired pressure.
NOTE
With non-relieving regulators, make pressure reductions with some air flow in the system. If made under no flow (dead-end) conditions, the regulator will trap the over-pressure in the downstream line.
4. KNOB ADJUSTMENT. Push lockring on knob down to
lock pressure setting. Pull lockring up to release. Install tamper resistant wire (see Replacement Items) to make setting tamper resistant.
5. T-BAR ADJUSTMENT. Tighten lock nut (4) lock pressure
setting.
© Norgren 2001
IM-341.200
(5/01)
Pressure Regulator
R17 - ★★★ - ★★★★
Thread Form
A....PTF
B....ISO Rc taper
G....ISO G parallel
Port
6....3/4"
8....1"
A....1-1/4"
B....1-1/2"
Relief Type
R....Relieving
N....Non relieving
Gauge
G....With
N....Without
Adjustment Type
0....Knob
1....T-Handle
* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
Spring (Outlet Pressure Range) *
E....0,3 to 3,5 bar (5 to 50 psig)
L....0,3 to 8,5 bar (5 to 125 psig)
S....0,7 to 17 bar (10 to 250 psig)
Option
0....Not applicable
2
1
7
8
9
18
16
15
17
14
13
12
3
4
6
5
10
11