See Section ALE-24 for Accessories
Littleton, CO USA Phone 303-794-2611 www.norgren.com
B74G
● EXCELON design allows in-line or modular
installation
● Quick release bayonet bowl
● Highly visible, prismatic liquid level indicator lens
● Full flow gauge ports
● Balanced valve design minimizes effect of variation
in the inlet pressure on the outlet pressure
● Modular installations with EXCELON 72, 73, and 74
series can be made to suit particular applications
Excelon®74 Series Filter/Regulator
3/8",1/2",3/4" Port Si zes
ALE-12-8
Ordering Information. Models listed include PTF threads, knob adjustment, automatic drain, metal bowl with liquid level indicator, 40 µm element,
relieving diaphragm, 5 to 150 psig (0.3 to 10 bar) outlet pressure adjustment range*, with gauge.
† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.
Main Port Size Model Number Flow†scfm (dm3/s) Weight lb (kg)
3/8" B74G-3AK-AD3-RMG 163 (77) 2.62 (1.19)
1/2" B74G-4AK-AD3-RMG 212 (100) 2.59 (1.17)
3/4" B74G-6AK-AD3-RMG 212 (100) 2.55 (1.16)
Alternative Models
B 7 4-G
★ ★
-
★★ ★ ★
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel G
Adjustment Substitute
Knob K
T-bar T
Diaphragm Substitute
Relieving R
Non relieving N
Gauge Substitute
With G
Without N
Outlet Pressure
Adjustment Range* Substitute
5 to 60 psig (0.3 to 4 bar) F
5 to 150 psig(0.3 to 10 bar ) M
10 to 250 psig (0.7 to 17 bar )** S
Bowl Substitute
Metal with liquid level indicator D
Transparent with guard P
Element Substitute
5 µm 1
25 µm 2
40 µm 3
-
★★ ★
* Outlet pressure can be adjusted to pressures in e xcess of, and less than, those
specified. Do not use these units to control pressures outside of the specified
ranges.
** Units with 250 psig (17 bar) outlet pressure range are available only with the Tbar adjustment; therefore substitute T at the 7th digit and Sat the 12th position.
Drain Substitute
Automatic A
Manual, 1/4 turn Q
Port Size Substitute
3/8" 3
1/2" 4
3/4" 6