See Section ALE-24 for Accessories
Littleton, CO USA Phone 303-794-2611 www.norgren.com
B07
● Compact design
● Full flow gauge ports
● Low torque, non-rising adjusting knob
● Snap action knob locks pressure setting when
pushed in
● Standard relieving models allow reduction of outlet
pressure even when the system is dead-ended
● Protects air operated devices by removing liquid and
solids contaminants
● Screw-on bowl reduces maintenance time
● Can be disassembled without the use of tools or
removal from the air line
Series 07 General Purpose Filter/Regulator
1/8" and 1/4" Port Sizes
ALE-12-2
ISO Symbols
Automatic Drain
Relieving
Manual Drain
Relieving
Automatic Drain
Non Relieving
Manual Drain
Non Relieving
Alternative Models
-
★★★ ★★ ★
-
0★B 7
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel G
Drain Substitute
Automatic A
Manual M
Port Size Substitute
1/8
"
1
1/4
"
2
Element Substitute
5 µm 1
Bowl Relief Type Gauge Substitute
Transparent Relieving Without 01
Transparent Relieving With 02
Transparent Non-relieving Without 03
Transparent Non-relieving With 23
Metal Relieving Without 33
Metal Relieving With 34
Metal Non-relieving Without 35
Metal Non-relieving With 36
Outlet Pressure Adjustment Ranges* Substitute
1 to 10 psig (0.1 to 0.7 bar) A
5 to 50 psig (0.3 to 3.5 bar) E
5 to 100 psig (0.3 to 7 bar) K
5 to 125 psig (0.3 to 8.6 bar) L
Ordering Information. Models listed include PTF threads, transparent bowl, relieving diaphragm, gauge, automatic drain, 5 µm element, 5 to
100 psig (0.3 to 7 bar) outlet pressure adjustment range* .
Port Size Model Number Flow† scfm (dm3/s) Weight lbs (kg)
1/8" B07-102-A1KA 13 (6.2 dm3/s) 0.57 (0.26)
1/4" B07-202-A1KA 14 (6.5 dm3/s) 0.57 (0.26)
* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified
ranges.
† Typical flow with 100 psig (7 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.