Nordyne AireCare 707831C User Manual

AireCare TM Electronic Air Filter
For M1 and E2 Series Furnaces
Congratulations on your installation of an
AireCare TMElectronic Air Filter - the newest
and one of the most efficient ways to reduce indoor air pollution in the home. Used correctly, it will help protect your indoor
environment from allergy causing pollutants such as pollen, plant spores, lung damaging
particles like tobacco and cooking smokes,
fungi, bacteria, and some viruses.
iMPORTANT: Read all instructions carefully before starting the installation. Specifica- tions or designs are subject to change or
discontinuance without notice and without
incurring obligations.
These instructions are primarily intended to assist qualified individuals experienced in the
proper installation of heating and/or air condi- tioning appliances. Some local codes require licensed installation/service personnel for this
type of equipment.
WARNING:
improper installation may damage equipment, create a hazard, and will void thewarranty. DO NOT CONNECT
TO 110 Volts AC - the unit is designed to operate on 24 VAC.
/!X DANGER:
Shut off electrical supply to the furnace at the household breaker box
to prevent electrical shock and avoid
injury.
M1 AireCare TM Electronic Air Filter
Installation Instructions
Before starting this installation, make sure that all electrical power to the furnace has been
disconnected.
The M1 AireCare TM Electronic Air Filter kit con- sists of two brackets, four screws, a filter grille,
two protective edging strips, and the electronic air filter with power cable. To install the kit, the
two brackets must be mounted onto the door of the M1 furnace as shown in Figure 1.
Install the Brackets
1. install the protective sheet metal edging strips into the upper left louver of the M1
door (See Figure 1).
2. Locate the bottom bracket (See Figure 1) and remove the protective tape from the
back.
3. Place the bracket into the bottom louver of the M1 door with the flange pointing to-
wards the top of the door. Permanently
mount the bracket to the door using two of the supplied screws.
4. Locate the top bracket (See Figure 1) and remove the protective tape from the back.
5. Place the bracket into the top louver of the M1 door with the flange pointing towards
the bottom of the door. Permanently mount the bracket to the door using two of the
supplied screws.
Install the Filter
1. Connectthe electronicairfilterpowerwires (24 VAC) to the red and gray low voltage
terminals (R and C). Run this wire through the left side of the top louver of the M1 door. Connect the power wire marked with white
stripe or dash to C, the other to R. Place the door on the furnace and latch.
2. Place the electronic air filter into the brack- ets on the door by inserting it up into the top
bracket then allowing it to drop into the bottom bracket.
3. Connect the electronic air filter power wire
jack into the filter. Power the furnace. The AireCare TM Electronic Air Filter is active if
the light on top of the electronic air filter is lit.
4. Place the filter grille over the top bracket. There are two tabs that attach the grille to the top bracket. The grille will now fit over
the bottom bracket and is held there by a permanent magnetic.
AireCare
Electronic
Air Filter
Protective
Edging Strips
Upper Bracket
Lower
Bracket
Grille
Figure 1. M1 Bracket Installation
E2 AireCare TM Electronic Air Filter
installation Instructions
(2-4 Ton A/C)
Before starting this installation, make sure that all electrical power to the furnace has been disconnected.
The E2 electronic air filter kit consists of one filter bracket, two screws, and the electronic air
filter with power cable.
Install the Brackets
1. Remove the grille from the top of the furnace.
2. As shown in Figure 2, place the filter bracket into the grille frame and attach using the
two screws provided.
Install the Electronic Air Filter
1. Connect the electronic air filter power wires (24 VAC) to the red and gray (or black) low
voltage terminals (R and C) in the E2 furnace. Connect the power wire marked
with awhite stripe or dash to C, the other to
R.
2. Place the filter into the filter bracket and con- nect the filter power cable by plugging it into
the connector located at the top of the filter.
3. Turn on power to the furnace. The
AireCare TM Electronic Air Filter is active
if the light on top of the electronic air filter is lit.
4. Replace the grille.