Nordson Ultimus V Operating Manual

Ultimus V High Precision Fluid Dispenser
Operating Manual
Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com
Ultimus V High Precision Fluid Dispenser
You have selected a reliable, high-quality dispensing system from Nordson EFD, the world leader in fluid dispensing. The Ultimus™ V high precision dispenser was designed specifically for industrial dispensing and will provide you with years of trouble-free, productive service.
This manual will help you maximize the usefulness of your UltimusV high precision dispenser.
Please spend a few minutes to become familiar with the controls and features. Follow our recommended testing procedures. Review the helpful information we have included, which is based on more than 50years of industrial dispensing experience.
Most questions you will have are answered in this manual. However, if you need assistance, please do not hesitate to contact EFD or your authorized EFD distributor. Detailed contact information is provided on the last page of this document.
The Nordson EFD Pledge
Thank You!
You have just purchased the world’s finest precision dispensing equipment.
I want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.
If at any time you are not fully satisfied with our equipment or the support provided by your Nordson EFD Product Application Specialist, please contact me personally at 800.556.3484 (US), 401.431.7000 (outside US), or Tara.Tereso@nordsonefd.com.
I guarantee that we will resolve any problems to your satisfaction.
Thanks again for choosing Nordson EFD.
Tara
Tara Tereso, Vice President
2 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Contents

Contents ..........................................................................................................................................................................3
Nordson EFD Product Safety Statement ........................................................................................................................4
Halogenated Hydrocarbon Solvent Hazards ...............................................................................................................5
High Pressure Fluids ....................................................................................................................................................5
Qualified Personnel ......................................................................................................................................................5
Intended Use ...............................................................................................................................................................6
Regulations and Approvals ..........................................................................................................................................6
Personal Safety ............................................................................................................................................................6
Fire Safety ....................................................................................................................................................................7
Preventive Maintenance ..............................................................................................................................................7
Important Disposable Component Safety Information ................................................................................................8
Action in the Event of a Malfunction ............................................................................................................................8
Disposal .......................................................................................................................................................................8
Specifications ..................................................................................................................................................................9
UltimusV Features ........................................................................................................................................................10
Unpacking the Dispenser ..............................................................................................................................................11
Features and Controls ...................................................................................................................................................12
Front Panel ................................................................................................................................................................12
Back Panel .................................................................................................................................................................13
Initial Setup for Testing..................................................................................................................................................14
Connect Power ..........................................................................................................................................................14
Connect Foot Pedal ...................................................................................................................................................14
Connect Air Input ......................................................................................................................................................14
Connect Air Output ...................................................................................................................................................14
Attach Syringe Barrel and Tip ...................................................................................................................................14
Dispensing System Setup .............................................................................................................................................15
Using Steady Mode to Dispense a Dot or Stripe or Fill a Cavity ...............................................................................15
Using Timed Mode to Make Repeatable Deposits ....................................................................................................16
Using the Vacuum Control Feature for Low Viscosity Fluids ...................................................................................16
Filling the Syringe Barrel ............................................................................................................................................17
Initial Settings ................................................................................................................................................................18
Basic Menu Operation ...................................................................................................................................................19
Setting the Real Time Clock ......................................................................................................................................19
Setting the Date .........................................................................................................................................................19
Setting Units of Pressure ...........................................................................................................................................20
Setting Units of Vacuum ............................................................................................................................................20
Setting Language .......................................................................................................................................................20
General Operator Lockout Procedures......................................................................................................................21
Setting a New Password ...........................................................................................................................................22
Clearing a Password ..................................................................................................................................................22
Alarm Options Screen ................................................................................................................................................22
Communications Port Options Screen ......................................................................................................................24
Contrast Control ........................................................................................................................................................24
Information Screen ....................................................................................................................................................24
Setting Dispense Time, Pressure, And Vacuum ............................................................................................................25
Dispense Modes ............................................................................................................................................................25
Timed Mode ...............................................................................................................................................................25
Teach Mode ...............................................................................................................................................................25
Steady Mode .............................................................................................................................................................26
Setting Pressure ........................................................................................................................................................26
Setting Vacuum .........................................................................................................................................................26
Using Auto Increment Mode .........................................................................................................................................27
Dispense Count Mode ...............................................................................................................................................28
Time Mode .................................................................................................................................................................28
Auto Sequence Mode ................................................................................................................................................28
Sample Memory Cell Settings ...................................................................................................................................29
Part Numbers ................................................................................................................................................................30
Accessories ...................................................................................................................................................................30
Continued on next page
3www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Contents (continued)
Replacement Parts
Ultimus V ....................................................................................................................................................................30
Optimeter ...................................................................................................................................................................32
Appendix A — I/O Connector Pin Descriptions ............................................................................................................33
Appendix B — RS-232 Connection Protocol ................................................................................................................37
........................................................................................................................................................30

Nordson EFD Product Safety Statement

WARNING
The safety message that follows has a WARNING level hazard.
Failure to comply could result in death or serious injury.
ELECTRIC SHOCK
Risk of electric shock. Disconnect power before removing covers and / or disconnect, lock out, and tag switches before servicing electrical equipment. If you receive even a slight electrical shock, shut down all equipment immediately. Do not restart the equipment until the problem has been identified and corrected.
CAUTION
The safety messages that follow have a CAUTION level hazard.
Failure to comply may result in minor or moderate injury.
READ MANUAL
Read manual for proper use of this equipment. Follow all safety instructions. Task- and equipment­specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure these instructions and all other equipment documents are accessible to persons operating or servicing equipment.
MAXIMUM AIR PRESSURE
Unless otherwise noted in the product manual, the maximum air input pressure is 7.0 bar (100psi). Excessive air input pressure may damage the equipment. Air input pressure is intended to be applied through an external air pressure regulator rated for 0 to 7.0 bar (0 to 100 psi).
RELEASE PRESSURE
Release hydraulic and pneumatic pressure before opening, adjusting, or servicing pressurized systems or components.
BURNS
Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury.
4 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Nordson EFD Product Safety Statement (continued)

Halogenated Hydrocarbon Solvent Hazards

Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components. Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage. Halogenated hydrocarbon solvents contain one or more of the following elements.
Element Symbol Prefix
Fluorine F “Fluoro-” Chlorine Cl “Chloro-” Bromine Br “Bromo-” Iodine I “Iodo-”
Check the Safety Data Sheet (SDS) or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your EFD representative for compatible EFD components.

High Pressure Fluids

High pressure fluids, unless they are safely contained, are extremely hazardous. Always release fluid pressure before adjusting or servicing high pressure equipment. A jet of high pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning.
WARNING
Any injury caused by high pressure liquid can be serious. If you are injured or even suspect an injury:
• Go to an emergency room immediately.
• Tell the doctor that you suspect an injection injury.
• Show the doctor the following note.
• Tell the doctor what kind of material you were dispensing.
Medical Alert — Airless Spray Wounds: Note to Physician
Injection in the skin is a serious traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream.

Qualified Personnel

Equipment owners are responsible for making sure that EFD equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks.
5www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Nordson EFD Product Safety Statement (continued)

Intended Use

Use of EFD equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include:
• Using incompatible materials.
• Making unauthorized modifications.
• Removing or bypassing safety guards or interlocks.
• Using incompatible or damaged parts.
• Using unapproved auxiliary equipment.
• Operating equipment in excess of maximum ratings.
• Operating equipment in an explosive atmosphere.

Regulations and Approvals

Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be impaired.

Personal Safety

To prevent injury, follow these instructions:
• Do not operate or service equipment unless you are qualified.
• Do not operate equipment unless safety guards, doors, and covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices.
• Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement.
• Make sure spray areas and other work areas are adequately ventilated.
• When using a syringe barrel, always keep the dispensing end of the tip pointing towards the work and away from the body or face. Store syringe barrels with the tip pointing down when they are not in use.
• Obtain and read the Safety Data Sheet (SDS) for all materials used. Follow the manufacturer’s instructions for safe handling and use of materials and use recommended personal protection devices.
• Be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons.
• Know where emergency stop buttons, shutoff valves, and fire extinguishers are located.
• Wear hearing protection to protect against hearing loss that can be caused by exposure to vacuum exhaust port noise over long periods of time.
6 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Nordson EFD Product Safety Statement (continued)

Fire Safety

To prevent a fire or explosion, follow these instructions:
• Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected.
• Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored.
• Do not heat materials to temperatures above those recommended by the manufacturer. Make sure heat monitoring and limiting devices are working properly.
• Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local codes or the SDS for guidance.
• Do not disconnect live electrical circuits when working with flammable materials. Shut off power at a disconnect switch first to prevent sparking.
• Know where emergency stop buttons, shutoff valves, and fire extinguishers are located.

Preventive Maintenance

As part of maintaining continuous trouble-free use of this product, Nordson EFD recommends the following simple preventive maintenance checks:
• Periodically inspect tube-to-fitting connections for proper fit. Secure as necessary.
• Check tubing for cracks and contamination. Replace tubing as necessary.
• Check all wiring connections for looseness. Tighten as necessary.
• Clean: If a front panel requires cleaning, use a clean, soft, damp rag with a mild detergent cleaner. DO NOT USE strong solvents (MEK, acetone, THF, etc.) as they will damage the front panel material.
• Maintain: Use only a clean, dry air supply to the unit. The equipment does not require any other regular maintenance.
• Test: Verify the operation of features and the performance of equipment using the appropriate sections of this manual. Return faulty or defective units to Nordson EFD for replacement.
• Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD representative for information and advice.
7www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Nordson EFD Product Safety Statement (continued)

Important Disposable Component Safety Information

All Nordson EFD disposable components, including syringe barrels, cartridges, pistons, tip caps, end caps, and dispense tips, are precision engineered for one-time use. Attempting to clean and re-use components will compromise dispensing accuracy and may increase the risk of personal injury.
Always wear appropriate protective equipment and clothing suitable for your dispensing application and adhere to the following guidelines:
• Do not heat syringe barrels or cartridges to a temperature greater than 38° C (100° F).
• Dispose of components according to local regulations after one-time use.
• Do not clean components with strong solvents (MEK, acetone, THF, etc.).
• Clean cartridge retainer systems and barrel loaders with mild detergents only.
• To prevent fluid waste, use Nordson EFD SmoothFlow™ pistons.

Action in the Event of a Malfunction

If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps:
1. Disconnect and lock out system electrical power. If using hydraulic and pneumatic shutoff valves, close and relieve pressure.
2. For Nordson EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For Nordson EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
3. Identify the reason for the malfunction and correct it before restarting the system.

Disposal

Dispose of equipment and materials used in operation and servicing according to local codes.
8 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Specifications

NOTE: Specifications and technical details are subject to change without prior notification.
Item Specification
Cabinet size 22.5 Weight 3.4 kg (7.7 lb) Input AC (to power supply) 100–240 VAC (±10%), 50/60 Hz, 0.5 A Output DC (from power supply) 24 VDC, 1.66 A maximum Internal voltage 24 VDC Cycle rate Exceeds 600 cycles per minute Time range 0.0000–9.9999 s Foot pedal Voltage: 24 VDC
End-of-cycle feedback circuits 5–24 VDC, 100 mA maximum Cycle initiate Foot pedal, finger switch, or 5–24 VDC signal Input air pressure 7.0 bar (100 psi) maximum Air output 0–7.0 bar (0–100 psi) Ambient operating conditions Temperature: 5–50° C (41–122° F)
Product classification Installation: Category II
Approvals CE, TÜV, RoHS, WEEE, China RoHS
W x 9.50H x 19.9D cm (8.86W x 3.74H x 7.85D”)
Current: 20 mA
Humidity: 85% RH at 30° C non-condensing Height above sea level: 2,000 m max (6,562 ft)
Pollution: Degree 2
RoHS标准相关声明标准相关声明 (China RoHS Hazardous Material Declaration)
产品名称
Part Name
外部接口
External Electrical Connectors
O:表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C
的标准低于SJ/T11363-2006限定要求。
Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is below the limit requirement in SJ/T11363-2006.
X:表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C
的标准高于SJ/T11363-2006限定要求.
Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the limit requirement in SJ/T11363-2006.
有害物质及元素
Toxic or Hazardous Substances and Elements
铅 
Lead
(Pb)
汞 
Mercury
(Hg)
镉 
Cadmium
(Cd)
六价铬
Hexavalent Chromium (Cr6)
多溴联苯
Polybrominated Biphenyls (PBB)
X 0 0 0 0 0
多溴联苯醚
Polybrominated Diphenyl Ethers (PBDE)
WEEE Directive
This equipment is regulated by the European Union under WEEE Directive (2012/19/EU). Refer to
www.nordsonefd.com/WEEE for information about how to properly dispose of this equipment.
9www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
UltimusV Features
• Electronically change / adjust dispensing Time, Pressure, and Vacuum
• Simultaneously display dispensing Time, Pressure, and Vacuum
• Auto Increment mode to adjust dispensing parameters after a certain number of shots or
a specific lapsed time
• Auto Sequence mode that allows deposit patterns to be repeated automatically
• 400 individual memory storage cells
• Scroll or select cells via front panel keypad or external PC / PLC control
• Switching between Steady, Timed, and Teach modes
• Front panel Manual Cycle key
• Teach function
• Multi-level operator lockout
• Alarm indicators
• End of Cycle Feedback loop
• Soft button data input 0–9 keypad
• Operator control of LCD display brightness
• Easy UP / DOWN arrow key navigation
• External PC interface for data input
• Display cycle counter
• RS-232 interface compatible with standard RS-232 protocol
• ESD-safe via connection with external ESD grounding plug
• 0–7.0 bar (0–100 psi) air regulation range; 0–18 H2O vacuum regulation range
• Internal universal power supply
• D-sub I/O (15-pin) and communication (9-pin) connections
• Alarm input / output I/O signals
10 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.

Unpacking the Dispenser

Unpack the contents of the package and lay them out on a clean workbench.
5
Ultimus V High Precision Fluid Dispenser
8
6
14
9
10
13
The following items should be included with your UltimusV dispenser:
Tubing — 6 mm OD Blue Urethane
1.
Connector 15 Pos Plug D-Sub Solder
2.
Backshell 15 Pos D-Sub
3.
Hose Support Adapter
4.
Filter Regulator
5.
Power Cord, American Plug
6.
Foot Pedal Assembly
7.
Barrel Holder Sleeve
8.
Barrel Holder
9.
Ergonomic Barrel Holder
10.
Hose Support Locating Washer
11.
Fitting — 1/4 NPT X 6 mm OD
12.
Wrench — Hex Key, 4 mm
13.
Screw — M6 X 25 mm, Bh, Blk
14.
11
4
12
1
7
3
2
(Not Shown) Literature — Optimum Component Poster Dot Test Kit Sheet Box of 50 tip caps
11www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Features and Controls

RS-232 Connector
Power Switch
LCD Display
Function Buttons
Cycle Button
Air Output Quick Connector
ESD Jack
Numeric Keypad
Scroll Keys
Easy Adjust
Buttons
Enter Key

Front Panel

Power Switch: Turns the UltimusV dispenser on and off. RS‑232 Connector: Allows all dispensing parameters to be modified from a remote PC or PLC. LCD Display: Shows data and system status as well the current function selected. Function Buttons: Used to select items shown on the bottom of the LCD display above the individual function
buttons. The function of each key depends on the current screen display and / or mode. Cycle Button: Initiates a dispense cycle.
Air Output Quick Connector: Syringe barrel adapter / Optimeter ESD Jack: Standard 0.166" banana jack allows the user to connect grounding for ESD-sensitive equipment. Numeric Keypad: Used to enter settings. Scroll Keys: The arrow-shaped 2,4, 6, and 8 keys on the numeric keypad can be used for cursor scrolling as well as
data entry.
Easy Adjust Buttons: Adjusts dispense time or memory cell location.
Enter Key:
Confirms highlighted selection or data entered.
connection.
12 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser
Features and Controls (continued)

Back Panel

Air In: Main filtered air supply input.
6 mm push-in fitting, used to connect main air supply. Minimum 1.0 bar (15 psi) above desired dispensing pressure; maximum 0–7.0 bar (0–100 psi).
Exhaust: Syringe barrel and vacuum air exit port. 6 mm push-in fitting. Output air from the syringe barrel exits from this port at the end of every dispensing cycle. The air consumed by the vacuum generator exhausts through this port as well. The push-in fitting allows tubing to be connected for remote discharge.
Foot Pedal / Finger Switch Connector: Connection for dispenser actuating device. Connection is for a momentary contact closure switching device. EFD strongly suggests the use of EFD foot pedals and finger switches, which are specifically designed for this application.
RS‑232 Connector: (DB-9 Male Style) Either the front or rear RS-232 port can be enabled at one time. The RS-232 port is selected in the Communication LCD screen.
Any communications to the disabled RS-232 port will be ignored by the dispenser. The RS-232 protocol is covered in Appendix B.
I/O (Input / Output) Connector: (DB-15 Female Style) Used to connect to any input or output. For detailed pin information, refer to Appendix A.
AC Power Input: Connects dispenser to local power source.
Air In
Exhaust
Foot Pedal /
Finger Switch
Connector
RS-232
Connector
Power Input
I/O (Input / Output)
Connector
Jack
13www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Initial Setup for Testing

Connect Power

1. Connect the power cord to the back of the dispenser.
2. Plug the power cord into your local power source.
3. Turn the power switch on the front panel to the on position.

Connect Foot Pedal

The UltimusV can be operated using the foot pedal provided, or by an external device via a DB-15 connector.
1. Plug the foot pedal into the connector on the back of the dispenser.
2. You can also operate the UltimusV with an optional finger switch or a 5 to 24
VDC pulse.

Connect Air Input

NOTE: Clean, dry, filtered factory air is required to meet warranty. To ensure air
quality, install the five-micron filter regulator provided with the UltimusV.
1. Push one end of the air input hose into the Air In fitting on the back of the
dispenser.
2. Connect the other end of the air input hose to the filter regulator supplied
with the UltimusV dispenser.
NOTE: Input air should be set at least 1.0 bar (15 psi) — or more — higher than dispensing pressure, up to a maximum of 0–7.0 bar (0–100 psi).

Connect Air Output

Push the connector on the adapter / Optimeter into the connector on the front of the UltimusV and twist clockwise to lock.

Attach Syringe Barrel and Tip

1. Secure an EFD syringe barrel filled with your fluid to the adapter / Optimeter.
2. Replace the tip cap with an appropriate EFD precision dispense tip.
14 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Dispensing System Setup

Deposit size is controlled by time, pressure and tip size. Please follow these instructions to test each function. Use the convenient Dot Standards sheet
included in your dispensing kit.

Using Steady Mode to Dispense a Dot or Stripe or Fill a Cavity

1. Start with pressure set to zero.
2. Place the syringe barrel over a piece of paper or test surface.
3. Place the unit in “Steady” mode.
4. Unsnap the safety clip. Depress and hold the foot pedal for the remainder of setup.
5. While resting the tip on the paper (test surface), increase the air pressure by 0.069–0.138 bar
(1–2 psi) using the keypad until you have reached the desired fluid dispensing flow rate.
NOTE: Always use the lowest possible pressure and the largest possible tip size. The combination of the lowest possible output pressure + largest possible tip size + longest possible dispense duration = most consistent and accurate deposits.
6. Release the foot pedal.
7. Retest the dispensing rate a few more times. Fine tune as required by making small changes
in pressure.
Remember — always bring the tip in contact with the work surface at the illustrated angle. After the tip is in position, press the foot pedal. Release pedal and remove tip by lifting straight up.
Correct angle for consistent deposits.
15www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Ultimus V High Precision Fluid Dispenser

Using Timed Mode to Make Repeatable Deposits

1. Refer to the previous section to purge your dispense tip of air and fill it with fluid.
2. Place the unit into “Timed” mode.
3. Set the dispense time. The dispense time or duration may be set in one of two ways:
• Using the Up / down Arrows to set time. Refer to the “Features and Controls” section.
• Using the Program / Teach button to set time. Refer to the “Features and Controls” section.
4. Press the foot pedal / finger switch to activate the dispense cycle. The dispenser will now continuously
dispense for the pre-set duration of time. Once the time has expired, the dispenser will stop dispensing and await another triggering signal from the foot pedal / finger switch or signal from the host controller.
NOTE: The foot pedal / finger switch only needs to be pressed for a moment. If the foot pedal / finger switch or contact closure I/O signal is initiated at any time during the dispense cycle,
the dispenser will immediately abort and stop dispensing. This is a unique safety feature to prevent accidental dispensing.

Using the Vacuum Control Feature for Low Viscosity Fluids

The Vacuum Control feature allows you to dispense low viscosity fluids consistently without dripping between cycles. The vacuum overcomes head pressure on the fluid within the barrel, which prevents dripping.
1. Make sure that you have attached an EFD syringe barrel filled with the
fluid intended for dispensing, and that the air pressure is set all the way to zero. EFD recommends the use of a Blue LV Barrier piston for watery, low viscosity materials.
2. Make sure the barrel adapter safety clip is closed.
LV Barrier
Air gap
3. Remove the tip cap and replace it with an appropriate EFD dispense tip.
4. Set the air pressure at 0.1 bar (2 psi).
1/2 maximum fill
5. While pointing the tip over a container or resting it on a test surface, release
the safety clip on the adapter / Optimeter hose assembly.
6. Place the dispenser in “Steady” mode. Depress and hold the foot pedal
until a drip begins to form at the end of the tip.
7. Release the foot pedal. At this point, fluid will continue to exit the tip.
8. Increase the vacuum using the keypad by 0.5 to 1.0 inches of water until
the fluid deposit size stabilizes without growing.
NOTE: Do not increase the vacuum to the point where the deposit is actually drawn back into the tip or to where bubbles form in the barrel. Excessive vacuum causes inconsistent dispensing.
9. Lift the tip off the test surface, wipe the tip end and retest by pressing the foot pedal momentarily. The deposit
should stay at the intended size and not increase or decrease in size. If it does, repeat steps 4–8 to fine-tune the vacuum control.
10. Once the vacuum is properly set, increase air pressure to the desired production setting before beginning your
dispensing process.
16 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.