Nordson 752V-HL Operating Manual

752V-HL Dispense Gun
Operating Manual
Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com
752V-HL Dispense Gun
Introduction
The 752V-HL (#7021415) hand-operated dispense gun is a rugged, industrial, lever-actuated fluid dispensing valve. The valve incorporates a quick change fluid body for fast and easy maintenance. The fluid inlet fitting for 1/4" OD feed tubing and an assortment of dispensing tips are included.
1. Install the feed tube from the fluid reservoir to
the inlet fitting and tighten the compression nut to secure. The location of the inlet fitting can be changed by removing the two fluid body retainer screws and fluid body. Follow the service instructions to reinstall the fluid body with the inlet fitting in the desired position.
2. Apply air pressure to the fluid reservoir. Start with
a low setting of 1.4 bar (20 psi). If using a Nordson EFD fluid reservoir, refer to the operating manual for further instructions.
Typical System Setup
#7002002 5-micron filter / regulator for clean, dry filtered factory air
For dispensing with cyanoacrylates, order #7016548 with coalescing filter.
3. Install an appropriate size dispensing tip on
the outlet tip adapter. Use large tips for high viscosity materials and small tips for low viscosity materials.
4. Press the hand lever to begin fluid flow. Release
the lever to stop fluid flow.
5. To achieve the desired flow, change the size of
the dispensing tip or adjust the reservoir fluid pressure.
Shutoff valve
#7020105
Hand-lever
valve stand
#7010004
accommodates a one
2 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.