SK TU3-EIP
Technical Information / Datasheet
Part number: 275 900 150
EtherNet/IP® - External bus – interface
ATTENTION
This document is only valid in combination with the operating instructions for the relevant frequency inverter. All
of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.
Validity of document
Scope of delivery
1 x Module SK TU3-EIP
Usage area
Technology box for connec ting a f requency inverter (S K 5xxE) t o a EtherNet/IP f ield bus. The m odule
must be attached directly to the technology slot of the frequency inverter.
Technical data
Module
Temperature range 0 °C … 40 °C Vibration resistance 2M1
Temperature class Class 3k3 Firmware version V1.1 R1
Protection class IP20 Hardware version AA
Supply voltage 24 V ± 20 %, ≈ 100 mA
Reverse polarity protected
Dimensions [mm] H x W x D: 27 x 73 x 101
EtherNet/IP Bus module SK TU3-EIP
1.1 LED - displays, technical datas, Error 10.9 4913 Rck TI 275900150 GB
version reason for change(s) issue name document speech
EtherNet/IP Bus module – SK TU3-EIP
DIP switches, module parameters, BOOTP and DHCP
diagnosis socket on the device (if available) and possibly
Bus specification
EtherNet/IP Max. 100 MBaud Cable Min. Ethernet CAT-5
Electrical isolation 500 V
Max. cable length 100 m between two
eff
modules
Bus connection 2 x RJ45 Shield via RJ sockets highbus termination Takes place automatically Ohmic & capacitive to PE
Status display 8 LEDs PE connection via PE post-type connector
Topology* Star*, ring, linear bus (rating less than 24 V)
* additional switch for "star" topology required
Performance
Update interval for process data between module and frequency inverter ≤ 2.5 ms
Parameter read access to frequency inverter ≈ 15 ms
Parameters write access with storage on EEPROM ≈ 25 ms
Cycle times ≥ 1ms
Pos: 6 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/EtherN et/IP/Mer kmale [EIP Al lgemein] @ 3\mod_1362996549668_388.docx @ 61397 @ 5 @ 1
Module features
IO messages (process data connections) One "Exclusive Owner“
Max. 2 “Listen Only” connections
Type "Cyclic", min cycle time 1 ms
Explicit messages Yes
UCMM Supported
DLR Supported
Switch with two ports integrated
Addressing via
possible
Access for NORD diagnosis tool via
via frequency converter and
Ethernet protocols UDP or TCP/IP
Pos: 9 /Anl eitungen/El ektronik /FU und Star ter/3. /4. Anzeige u nd Bedien ung [BU 050 0 / BU 0200 ]/SK 5xxE/ 3.2 Übersic ht der Tec hnologieboxen -2- Monta ge @ 1\mod_1340712929975_388.docx @ 28340 @ 5 @ 1
2 TI 275900150 - 4913
Push the control terminals cover down
edge and pulling off
with an upward turning movement. If
Installing
EtherNet/IP Bus module – SK TU3-EIP
Note
Installing the technology unit
Modules should not be inserted or removed unless the device is free of voltage. The slots may only be used for
the intended modules.
Installation of a technology unit separate from the frequency inverter is not possible. It must be connected directly
to the frequency inverter.
The technology units must be installed as follows:
1. Switch off the mains voltage, observe the
waiting period.
2.
slightly or remove.
3. Remove the blank cover, by loosening the
release on the lower
necessary, the attachm ent screw next to the
release must be removed.
4. Hook the technology unit onto the upper edge slots and press in lightly until it engages.
Ensure full contact with t he connector strip and fasten with the screws if necessary (separate
packet).
5. Close the control terminal cover again.
Pos: 12 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Et herNet/IP /Anschlüss e [SK TU3-E IP] @ 3\mod_1363958898449_388.docx @ 62382 @ 5 @ 1
Connections
The two Ethernet l ines are connected ex clusiv ely via t he two RJ45 sock ets on th e front. If the m odule
is the final subscriber on the line, one RJ45 socket can remain unoccupied.
( 1 ) RJ45 socket detail ( 2 ) Power supply detail
Pos: 15 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Et herNet/IP /Konfigurati on [SK TU 3-EIP] @ 3\mod_1363947436882_388.docx @ 62357 @ 5 @ 1
TI 275900150 - 4913 3