NORD TI 275281172 User Manual

only valid in combination with the operating instructions for the relevant frequency inverter. All
Technical Information / Datasheet
Pos: 6 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/SK TU4- PNT-M12-C / 27528117 2 / Basi s i nformati o ne n [S K TU4-PNT-M12- C] @ 4\mod_1385375045040_388.docx @ 106503 @ 555 @ 1
SK TU4-PNT-M12-C
Part number: 275 281 172
PROFINET IO® - External Bus – Interface
NOTICE
This document is of the information that is relevant for a safe start-up of this module and the frequency inverter is only available under these conditions.
Validity of this document

Scope of delivery

1 x Module SK TU4-PNT-M12-C 4 x Hexagon socket M4 x 40 mm
Accessories required:
1 x Bus connection unit SK TI4-TU-BUS-C TI 275280500 (Part No. 275 280 500)

Field of use

External technolog y unit for c onnecti on of a dec entral ised f requency inverter (SK 1 80E … S K 2xxE) to a PROFINET IO field bus. The module can be mounted on, or in the immediate vicinity of the frequency inverter. I t is connected to the inverter via the system bus, and can comm unicate directly with up to 4 frequency inverters. 8 digital inputs and 2 digital outputs are available.

Technical data

Module
Temperature range -25 °C … 50 °C Vibration resistance 3M7 Temperature class Class 3K4 Firmware version V1.2 R0 (from 2014) Protection class IP66 Hardware version AA
Supply voltage 24 V ± 20 %, ≈ 100 mA
Dimensions [mm]* H x W x D: 95 x 136 x 99
Reverse polarity protected
* module fitted to BUS-connection unit
Depth: 108mm with covers on M12
-connection
PROFINET IO Bus module SK TU4-PNT-M12-C
1.0 Erstausgabe / first issue 4913 Rck TI 275281172 GB
version reason for change(s) issue name document speech
PROFINET IO Bus module – SK TU4-PNT-M12-C
Isochronous real time communication of synchronised
Transmission and receiver cables are automatically
diagnosis socket on the device (if available) and possibly
Digital input - working area Low: 0 V … 5 V, High: 15 V … 30 V Digital input - specif ic dat a Ri = 8 kΩ, input capacity: 10 nF, response time 3 ms,
inputs as per EN 61131-2 type 1 Digital output - 24 VDC power supply ≤ 400 mA (input) Digital output - working range Low = 0 V, High = 24 V; max. 200 mA
Bus specification
EtherNet/IP Max. 100 MBaud Cable Min. Ethernet CAT-5 Electrical isolation 500 V
Max. cable length 100 m between two
eff
modules Bus connection 2 x M12 sockets Shield via M12 direct to PE Bus termination performed automatically PE connection via PE screw connection Status display 8 LEDs in the terminal box Topology Star, tree, ring, linear bus
Performance
Update interval for process data betw een module and frequency inverter ≤ 5 ms Parameter read access on the frequency inverter ≈ 15 ms Parameter write access with storage in EEPROM ≈ 25 ms Cycle times ≥ 1 ms
Pos: 8 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/Mer kmale [PNT Allgemein] @ 4\ mod_1385365458675_388.docx @ 106301 @ 5 @ 1

Module features

Communication RT (Real Time)
à Real time communication of process data
IRT (Isochronous Real Time)
à process data
Addressing Automatic address assignment via IO controller using DCP
(Discovery Configuration Protocol) Data transfer via Switched Ethernet Autonegotiation Negotiation of transfer parameters Autocrossover
crossed in the switch as necessary Conformity classes CC-B, and CC-C Access for NORD diagnosis tool via
via frequency inverter and
Ethernet protocols UDP or TCP/IP
Pos: 11 /T echnische I nformatio nen/SK xU x - Bus - Erwei terungen/ Allgemein - Systemübergreifend/Montage [SK TU4-xxx-xxx] @ 2\mod_1353315135994_388.docx @ 51251 @ 5 @ 1

Installation

The module must be attac h ed to t he s u ita ble c o nn ec tio n un it (S K TI4-TU- …) and connected using th e four M4 x 40 mm provided hexagon s ocket collar sc rews. Installation det ails can be found in the data sheet for the relevant connection units.
Pos: 14 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - S ystemüberg reifend/Ans chlüsse - E thernetsei te - Variant e M12 [SK TU 4-...EIP/ ECT/POL/A nschlüsse - E thernetsei te - Variant e M12 [SK TU4-...EIP/ECT /POL/PNT(-M12) ...-C)] @ 4\mod_1385383150995_388.docx @ 106697 @ 5 @ 1
2 / 8 TI 275281172 - 4913
PROFINET IO Bus module – SK TU4-PNT-M12-C
PIN
Signal
Description
1
TX+
Transmission Data +
2
RX+
Receive Data +
3
TX-
Transmission Data -
4
RX-
Receive Data -
Potential
Contact
Designation
Description
1
24V
Supply potential (+24 V, ≤ 200 mA)
2
24V
Supply potential (+2 4 V, ≤ 200 mA)
3
DIN5
Digital input 5
4
DIN7
Digital input 7
5
DIN6
Digital input 6
6
DIN8
Digital input 8
7
0V
Reference potential (0 V / GND)
8
0V
Reference potential (0 V / GND)
9
24V
Supply potential (+24 V, ≤ 200 mA)
10
24V
Supply potential (+24 V, ≤ 200 mA)
11
24V
Supply voltage (+24 V)
12
24V
Supply voltage (+24 V)
13
24V
Supply voltage (+24 V)
14
SYS +
System bus data line +
15
0V
Reference potential (0 V / GND)
16
SYS -
System bus data line -
17
0V
Reference potential (0 V / GND)
18
0V
Reference potential (0 V / GND)
19
DIN1
Digital input 1
20
DIN3
Digital input 3
21
0V
Reference potential (0 V / GND)
22
0V
Reference potential (0 V / GND)
23
24V
Supply voltage (+24 V)
24
24V
Supply voltage (+24 V)
26
DIN4
Digital input 4
27
0V
Reference potential (0 V / GND)
28
0V
Reference potential (0 V / GND)
29
24V
Supply voltage (+24 V)
30
24V
Supply voltage (+24 V)
31
VI 24V2
Supply potential (+24 V - in) of the digital outputs
32
0V2
Reference potential (0 V / GND) of the digital outputs
33
DOUT1
Digital output 1 (+24 V, ≤ 200 mA)
34
DOUT2
Digital output 2 (+24 V, ≤ 200 mA)
35
0V2
Reference potential (0 V / GND) of the digital outputs
36
0V2
Reference potential (0 V / GND) of the digital outputs
RJ12 - 1
RS485_A
Data cable RS485
RJ12 - 2
RS485_B
Data cable RS485
RJ12 - 3
GND
Reference potential (GND)
RJ12 - 4
RS232_TxD
Data cable RS232
RJ12 - 5
RS232_RxD
Data cable RS232
RJ12 - 6
24 V
Supply voltage (+24 V)

Connections

The two Ethernet lines are connected exclusively via the two M12 sockets on the front. If the module is the final subscriber on the line, one M12 socket can remain unoccupied. The use of EMC screw connections is recommended.
PIN assignment M12-4 socket ("D“- coded):
Pos: 16 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - S ystemüberg reifend/Ans chlüsse - K lemmenleis te [SK TU 4(-C) - EtherNet B aug ruppen all g e mei n] @ 3\mod_1362998963057_388.docx @ 61424 @ @ 1
The connection to other signal and control lines takes place via the BUS - connection units.
1
Digital inputs
2
25 DIN2 Digital input 2
System bus level and digital inputs
3
Digital outputs
4
Diagnosis
TI 275281172 - 4913 3 / 8