combination with the operating instructions for the relevant frequency inverter. All
Technical Information / Datasheet
Pos: 4 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/SK TU4- PNT-C / 27528116 5 / Basisinfor mationen [S K TU4-PNT-C] @ 4\mod_1385374809425_388.docx @ 106478 @ 555 @ 1
SK TU4-PNT-C
Part number: 275 281 165
PROFINET IO® - External Bus – Interface
NOTICE
This document is only valid in
of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.
Validity of this document
Scope of delivery
1 x Module SK TU4-PNT-C
4 x Hexagon socket M4 x 40 mm
Accessories required:
1 x Bus connection unit SK TI4-TU-BUS-C
TI 275280500 (Part No. 275 280 500)
Field of use
External technolog y unit for c onnecti on of a dec entral ised f requency inverter (SK 1 80E … S K 2xxE) to
a PROFINET IO field bus. The module can be mounted on, or in the immediate vicinity of the
frequency inverter. I t is connected to the inverter via the system bus, and can comm unicate directly
with up to 4 frequency inverters. 8 digital inputs and 2 digital outputs are available.
Technical data
Module
Temperature range -25 °C … 50 °C Vibration resistance 3M7
Temperature class Class 3K4 Firmware version V1.2 R0 (from 2014)
Protection class IP66 Hardware version AA
Supply voltage 24 V ± 20 %, ≈ 100 mA
Dimensions [mm]* H x W x D: 95 x 136 x 109
Reverse polarity
protected
* module fitted to BUS-connection unit
Depth: 154 mm with cover caps on RJ45
-connection
PROFINET IO Bus module SK TU4-PNT-C
1.0 Erstausgabe / first issue 4913 Rck TI 275281165 GB
version reason for change(s) issue name document speech
PROFINET IO Bus module – SK TU4-PNT-C
Isochronous real time communication of synchronised
Transmission and receiver cables are automatically
socket on the device (if available) and possibly
Digital input - working range Low: 0 V … 5 V, High: 15 V … 30 V
Digital input - specif ic dat a Ri = 8 kΩ, input capacity: 10 nF, response time 3 ms,
inputs as per EN 61131-2 type 1
Digital output - 24 VDC power supply ≤ 400 mA (input)
Digital output - working range Low = 0 V, High = 24 V; max. 200 mA
Bus specification
EtherNet/IP Max. 100 MBaud Cable Min. Ethernet CAT-5
Electrical isolation 500 V
Max. cable length 100 m between two
eff
modules
Bus connection 2 x RJ45 sockets Shield Via RJ45 directly to PE
Bus termination performed automatically PE connection via PE screw connection
Status display 8 LEDs in the terminal box
Topology Star, tree, ring, linear bus
Performance
Update interval for process data between module and frequency inverter ≤ 5 ms
Parameter read access on the frequency inverter ≈ 15 ms
Parameter write access with storage in EEPROM ≈ 25 ms
Cycle times ≥ 1 ms
Pos: 8 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/Mer kmal e [PNT Allge mei n] @ 4\mod_1385365458675_388.docx @ 106301 @ 5 @ 1
Module features
Communication RT (Real Time)
à Real time communication of process data
IRT (Isochronous Real Time)
à
process data
Addressing Automatic address assignment via IO controller using DCP
(Discovery Configuration Protocol)
Data transfer via Switched Ethernet
Autonegotiation Negotiation of transfer parameters
Autocrossover
crossed in the switch as necessary
Conformity classes CC-B, and CC-C
Access for NORD diagnosis tool via diagnosis
via frequency inverter and
Ethernet protocols UDP or TCP/IP
Pos: 11 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - Systemübergreifend/Montage [SK TU4-xxx-xxx] @ 2\mod_1353315135994_388.docx @ 51251 @ 5 @ 1
Installation
The module must be attac h ed to t he s u ita ble c o nn ec tio n un it (S K TI4-TU- …) and connected using th e
four M4 x 40 mm provided hexagon s ocket collar sc rews. Installation det ails can be found in the data
sheet for the relevant connection units.
Pos: 15 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/PR OFINET IO /Anschlüss e [SK TU4-PN T(-C) - PROFINET IO Baugruppen mit RJ45 (SK TU4-PNT(-C)] @ 4\mod_1385379540114_388.docx @ 106672 @ 5 @ 1
2 / 8 TI 275281165 - 4913
PROFINET IO Bus module – SK TU4-PNT-C
Supply potential (+24 V, ≤ 200 mA)
Supply potential (+24 V, ≤ 200 mA)
Reference potential (0 V / GND)
Reference potent ial (0 V / GND)
Supply potential (+24 V, ≤ 200 mA)
Supply potential (+24 V, ≤ 200 mA)
Reference potential (0 V / GND)
Reference potential (0 V / GND)
Reference potential (0 V / GND)
Reference potential (0 V / GND)
Reference potential (0 V / GND)
Reference potential (0 V / GND)
Reference potent ial (0 V / GND)
Supply potential (+24 V - in) of the digital outputs
Reference potential (0 V / GND) of the digital outputs
Digital output 1 (+24 V, ≤ 200 mA)
Digital output 2 (+24 V, ≤ 200 mA)
Reference potential (0 V / GND) of the digital outputs
Reference potential (G ND )
Connections
The two Ethernet l ines are connected ex clusiv ely via t he two RJ4 5 sock ets on th e front. If the m odule
is the final participant on the line, one RJ45 socket can remain unoccupied.
PIN connections
RJ45 socket:
Pos: 16 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - S ystemüberg reifend/Ans chlüsse - K lemmenleis te [SK TU 4(-C) - EtherNet B aug ruppen all g e mei n] @ 3\mod_1362998963057_388.docx @ 61424 @ @ 1
The connection to other signal and control lines takes place via the BUS - connection units.
1
2
6 DIN8 Digital input 8
Digital inputs
System bus level and digital inputs
3
35 0V2 Reference potential (0 V / GND) of the digital outputs
Digital outputs
4
Diagnosis
TI 275281165 - 4913 3 / 8