NORD TI 275280500 User Manual

This document is only valid in combination with the operating instructions for the relevant frequency converter. All
Technical Information / Datasheet
Pos: 2 /Technis c h e Inf ormation en/ SK xUx - Bus - Erweiterung en/Ansc hlusseinhei t [SK TI4-TU-.. .]/SK TI4-TU4-BUS-C / 2752805 00 / Basisi nformati onen [SK TI 4-TU-BUS-C] @ 3 \mod_1364468636 695_388.docx @ 62945 @ 555 @ 1
SK TI4-TU-BUS-C
Bus connection unit
ATTENTION
of the information that is relevant for a safe start-up of this assembly and the frequency converter is only available under these conditions
Validity of document

Scope of delivery

1 x Bus connection unit SK TI4-TU-BUS-C 1 x System bus cable set grey / black 1 x 24 VDC cable set brown / blue 1 x PE cable green/yellow 1 x Gasket 2 mm, self-adhesive 2 x Leadthrough grommet 22 mm x 9.5 mm 4 x Hexagon socket M4 x 20 1 x Diaphragm valve M12x1.5 RAL9005 1 x Reducer (brass) M20 à M12

Usage area

The bus connection unit f orms the basis for the bus options and IO - expansions of model SK TU4-. The terminal strip is divided into three potential levels . The functions of the individual term inals are dependent upon the se lected field bus or IO - expansion and are not defined until both elem ents are joined together (BUS - connection un it and field bus or IO expansion). The BUS - connec tion unit can be fitted to or in the immediate vicinity of a frequency converter (SK 180E … SK 2xxE).

Technical data

Temperature range -25 °C … 50 °C Vibration resistance 3M7 Temperature class Class 3k4 Hardware version BB Protection class IP66 Dimensions [mm] H x W x D: 95 x 136 x 55 Current rating 3A
Pos: 3 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/Anschl usseinheit [SK TI4-TU-...]/M erkmale [SK TI 4-TU-BUS] @ 3\mod_1364469965939_388.docx @ 62995 @ 5 @ 1
Connection unit SK TI4-TU-BUS-C
1.0 Erstausgabe / first issue 1613 Rck TI 275280500 GB
version reason for change(s) issue name document speech
Connection unit – SK TI4-TU-BUS-C
Incoming or outgoing line for system bus or 24 V supply, for
Leadthrough for wiring between optional assembly and frequency

Features

1. No function, M20 x 1,5
2. Diagnosis access, RJ12 socket
3.
Cable entry M20 x 1.5 (1 on left, 1 on right):
example
4.
Cable entry M25 x 1.5 (2 pcs.):
converter with direct attachment.
5.
Cable entry M16x1.5 (4 pcs.): Leadthrough of wiring to sensors, actuators etc., direct attachment
Information
NORD can supply prefabricated M12 connection expansions for manufacturing plug-in connections.
System M12 connection expansion Part . No.
Profibus DP SK TIE4-M12-PBR 275274500 CANopen SK TIE4-M12-CAO 275274501 AS Interface SK TIE4-M12-ASI 275274502 AS Interface with aux. power SK TIE4-M12-ASI-AUX 275274513 Initiators / actuators SK TIE4-M12-INI 275274503 NORD system bus (outgoing) SK TIE4-M12-SYSM 275274505 NORD system bus (incoming) SK TIE4-M12-SYSS 275274506 24 V supply SK TIE4-M12-POW 275274507 Analog initiators / actuators SK TIE4-M12-ANA 275274508 Safe input (incoming) SK TIE4-M12-SH 275274509 HTL transmitter SK TIE4-M12-HTL 275274512
These can be screwed directly into the M16 cable lead-ins. The two existing side cable lead-ins (M20) can be used if a suitable reducer is used.
M12 connector
Pos: 4 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/Anschl usseinheit [SK TI4-TU-...]/M ontage [SK TI 4-TU-xxx] @ 3\mod_1364470201374_388.docx @ 63045 @ 5 @ 1

Installation

Installation location To the left or right of the frequency converter connection unit.
Alternatively using the wall mounting kit SK TIE4-WMK-TU (Mat no.: 275 274 002, TI 275274002) near the converter
Mounting Using screw connection (4 x hexagon socket M4 x 20)
ATTENTION
Ensure that no leaks are present during installation (assembly, cable leadthroughs, cable glands) in order to avoid penetration by moisture and therefore the risk of corrosion and short circuiting.
2 TI 275280500 - 1613
Sealing
Connection unit – SK TI4-TU-BUS-C
Remove the two M25 blind caps from the relevant side of the
(with terminal strip) from connection unit
Insert both of the provided leadthrough grommets into the M25 leadthroughs (to protect internal wiring between assembly and
(see point 3) and make the electrical
kit accessory pack) into the provided holes (countersunk) from the
the freely accessible holes in the rear panel from the inside and
The installation steps desc r ibe d in the following are va l id f or att ac hi ng a c onn ec tio n un it of the o pti ona l assemblies (SK TI4-TU- NET / BUS / MSW) to a frequency converter in model series SK 180E / SK 190E and SK 2xxE).
Installation steps for attachment to frequency converter
1. Switch off the mains power.
2. frequency inverter (right / left).
3.
Remove circuit board SK TI4-TU-….
4. Fit provided seal to SK TI4-TU-…. connection unit and fit to device with the 4 provided screw bolts.
5. frequency converter).
6.
Re-install circuit board connection.
7. Fit SK TU4 assembly and screw in place.
Wall mounting assembly steps
1. Switch off the mains power.
2. Install provided seal to SK TI4-TU-…. connection unit and attach to wall mounting kit. Screw the 2 cheese-head screws (wall mounting
outside.
3. Insert the two screw bolts (wall mounting kit accessory pack) into screw in place.
Install unit at usage location and make electrical connection (cable
4. length max 20m).
5. Attach SK TU4 assembly and screw in place.
TI 275280500 - 1613 3
Connection unit – SK TI4-TU-BUS-C
board. The terminals of the terminal strip in the BUS connection unit with identical potential are not connected to
assembly from condensation, the provided diaphragm valve must be screwed in. In order to do
this, remove the uppermost M20 cable screw connection and screw in the reducer that is also included in the Double tension
spring terminal
If installed to converter: make connection to PE of Interface for connecting
Document
Name
Document
Meaning
TI 275274002
Various
Data sheets for connection expansions
Information
Contacting
The connection between the field bus or IO - expansion and the BUS connection unit is made using a socket each other until the field bus or IO - expansion and the BUS connection unit ar e con nec ted to each other.
Pos: 5 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/Anschl usseinheit [SK TI4-TU-...]/Montage Ergänzung IP66 [SK T I4-TU-xxx-C] @ 3\mod_1364470637028_388.docx @ 63070 @ @ 1
ATTENTION
IP66 addition
To protect the scope of delivery.
The diagnosis access (transparent screw connection) may not be used for this purpose.
Pos: 6 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/Anschl usseinheit [SK TI4-TU-.. .]/Anschlüs se [SK TI 4-TU-BUS(-C)] @ 3 \mod_1364476178630_388.docx @ 63100 @ 5 @ 1

Connections

1 Terminal strip
strip
Wire cross-
AWG 14-26 rigid: 0.14 … 2.5 mm²
section
2 PE connection via housing
2 x 18 contacts
flexible: 0.14 … 1.5 mm² with wire end sleeves
converter using the provided cable (green/yellow).
3 Diagnosis RJ12 socket
parameterisation tool
Details of the functional ass ignment of the terminals can be found in the techn ical information of the relevant bus option or IO expansion of the SK TU4-.
Pos: 7 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/Anschl usseinheit [SK TI4-TU-...]/Weiterführende Dokument ationen und Software [S K TI4-TU-...] @ 3\mod_1364480506538_388.docx @ 63125 @ 5 @ 1

Additional documentation and software (www.nord.com)

Wall mounting kit for SK TIE4-WMK-TU
=== Ende der Liste für Textmar ke Inhalt ===
4 TI 275280500 - 1613
Loading...