NORD TI 275271019 User Manual

combination with the operating instructions for the relevant frequency inverter. All
Pos: 4 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/EtherN et/IP/SK CU4-E IP / 275271 019 / Basisi nformati onen [SK CU 4-EIP] @ 4\mod_1384951329490_388.docx @ 105631 @ 555 @ 1
SK CU4-EIP
Technical Information / Datasheet
EtherNet/IP® - Internal bus – interface
NOTICE
This document is only valid in of the information that is relevant for a safe start-up of this module and the frequency inverter is only available under these conditions.
Validity of the documents

Scope of supply

1 x Module SK CU4-EIP 1 x System bus cable set grey / black 1 x 24 VDC cable set brown / blue 2 x Connecting screws M4 x 20, cross-head

Field of use

Internal interface for connecting decentralised frequency inverter (SK 180E … SK 2xxE) to a EtherNet/IP field bus . It is connecte d to the inverter via the system bus and can respond directly with up to 4 frequency inverter. 2 digital inputs are available.

Technical data

Module
Temperature range -25°C … xx °C * Vibration resistance 3M7 Temperature class Class 3k3 Firmware version V1.2 R0 Protection class IP20 Hardware version AA
Supply voltage 24 V ± 20 %, ≈ 100 mA
Reverse polarity protected
* The upper temperature limit depends on the frequency inverter and the operating mode à see "Derating"
Digital input - working range Low: 0 V … 5 V, High: 15 V … 30 V Digital input - specif ic dat a Ri = 10 kΩ, input capacity: 10nF, reaction time 1 ms, inputs
according to EN 61131-2 type 1
EtherNet/IP Bus module SK CU4-EIP
1.1 LED - Anzeigen / LED displays, Derating 4913 Rck TI 275900150 GB
version reason for change(s) issue name document speech
EtherNet/IP Bus module – SK CU4-EIP
motor used (IE1 / IE2 / ...) restrictions to the permissible ambient temperature must be taken into account. If the
bient temperature is exceeded, the module may heat up to an impermissible extent and switch off
S3 ED 50 %, 10min
Motor
40°C
n. s.
S3 ED 70 %, 10min
Motor
n. s.
40°C
S1
Wall (ve ntilated)
47°C
48°C
DIP switches, module parameters, BOOTP and DHCP
diagnosis socket on the device (if available) and possibly
Bus specification
EtherNet/IP Max. 100 MBaud Cable Min. Ethernet CAT-5 Electrical isolation 500 V
Max. cable length 100 m between two
eff
modules Bus connection Screw terminals Shield Direct to PE bus termination performed automat ica lly PE connection via PE screw connection Status display 6 LEDs in the terminal box Topology Star, tree, linear bus
Performance
Update interval for process data between module and frequency inverter ≈ 2.5 ms Parameter read access on the frequency inverter ≈ 25 ms Parameter write access with storage in EEPROM ≈ 70 ms Cycle times ≥ 1 ms
Pos: 5 /Technis c h e Inf ormation en/ SK xUx - Bus - Erweiterung en/Allge mein - Syste mübergreif end/Derati ng [SK CU 4 - ...] @ 4\mod_1378288335408_388.docx @ 92917 @ 5 @ 1

Derating

ATTENTION
Derating
Depending on the installation location of the module (SK 180E, SK 190E or SK 2xxE), the operating mode (S1, S3 ...) and the installation type (wall-mounting, motor -mounting) of the frequency inverter as well as the type of
permissible am with an error message (E104.0).
Maximum ambient temperature *
Operating mode Installation type SK 180E / SK 190E SK 2xxE
S1 Motor 25°C 30°C
S1 Wall (unventilated) 37°C 42°C
* The limits of the frequency inverter must not be exceeded (refer to the frequency inverter manual).
Pos: 6 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/EtherN et/IP/Mer kmale [EIP Al lgemein] @ 3\mod_1362996549668_388.docx @ 61397 @ 5 @ 1

Module features

IO messages (process data connections) One "Exclusive Owner“ Max. 2 “Listen Only” connections Type "Cyclic", min cycle time 1 ms Explicit messages Yes UCMM Supported DLR Supported Switch with two ports integrated Addressing via
possible
Access for NORD diagnosis tool via
via frequency converter and Ethernet protocols UDP or TCP/IP
2 TI 275900150 - 4913
EtherNet/IP Bus module – SK CU4-EIP
Potential
Contact
Designation
Description
E8
PHY1 RX-
Ethernet connection 1 Receive Data -
E7
PHY1 RX+
Ethernet connection 1 Receive Data +
E6
PHY1 TX-
Ethernet connection 1 Transmission Data -
E5
PHY1 TX+
Ethernet connection 1 Transmission Data +
E4
PHY0 RX-
Ethernet connection 2 Receive Data -
E3
PHY0 RX+
Ethernet connection 2 Receive Data +
E2
PHY0 TX-
Ethernet connection 2 Transmission Data -
E1
PHY0 TX+
Ethernet connection 2 Transmission Data +
78
SYS -
System bus data line -
77
SYS +
System bus data line +
C1
DIN1
Digital input 1
C2
DIN2
Digital input 2
40
GND/0V
Reference potential (0 V / GND)
44
24V
Supply voltage (+24 V)
40
GND/0V
Reference potential (0 V / GND)
44
24V
Supply voltage (+24 V)
VI 24V
GND/0V
SYS +
SYS -
24V
GND/0V
SYS + SYS -
Pos: 8 /Technis c h e Inf ormation en/ SK xUx - Bus - Erweiterung en/Allge mein - Syste mübergreif end/Mont age [SK CU 4-xxx] @ 3\mod_1371811235059_388.docx @ 79455 @ 5 @ 1

Installation

Installation location Within the connection unit of a frequency inverter (SK 180E , SK 190E, 2xxE) Mounting with screw fastenings
Pos: 13 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - S ystemüberg reifend/Ans chlüsse [ SK CU4 - ...] @ 4\ mod_1378291237620_388.docx @ 93067 @ 5 @ 1

Connections

Connection is via the terminal bar of the module
1
Ethernet
2
digital inputs
System bus level and
Schematic diagram - electrical connection
(Terminal designation on example of NORD frequency inverter SK 180E … SK 2xxE)
SK CU4-… SK 180E … SK 2xxE
Pos: 16 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Et herNet/IP /Konfigurati on [SK CU 4-EIP] @ 4\mod_1384951929342_388.d ocx @ 105681 @ 5 @ 1
TI 275900150 - 4913 3
Loading...
+ 5 hidden pages