SK CU4-PNT
Technical Information / Datasheet
Part number: 275 271 015
PROFINET IO® - Internal Bus – Interface
NOTICE
This document is only valid in of the information that is relevant for a safe start-up of this module and the frequency inverter is only available under these conditions.
Validity of this document

Scope of delivery

1 x Module SK CU4-PNT 1 x System bus cable set grey / black 1 x 24 VDC cable set brown / blue 2 x Connecting screws M4 x 20, cross-head

Field of use

Internal interface f or the connection of a decentralise d frequency i nverter (SK 180E … SK 2xxE) to a PROFINET IO field bus . This is connec ted to the inverter v ia the system bus a nd can directly acc ess up to 4 frequency inverters. 2 digital inputs are available.

Technical data

Module
Temperature range -25°C … xx °C * Vibration resistance 3M7 Temperature class Class 3K3 Firmware version V1.2 R0 Protection class IP20 Hardware version AA Supply voltage 24 V ± 20 %, ≈ 100 mA
Reverse polarity protected
* The upper temperature limit depends on the frequency inverter and the operating mode à see "Derating"
Digital input - working range Low: 0 V … 5 V, High: 15 V … 30 V Digital input - specif ic dat a Ri = 10 kΩ, input capacity: 10 nF, response time 3 ms,
inputs as per EN 61131-2 type 1
PROFINET IO Bus module SK CU4-PNT
1.0 Erstausgabe / first issue 4913 Rck TI 275271015 GB
version reason for change(s) issue name document speech
PROFINET IO Bus module – SK CU4-PNT
Depending on the installation location of the module (SK 180E, SK 190E or SK 2xxE), the operating mode (S1, motor used (IE1 / IE2 / ...) restrictions to the permissible ambient temperature must be taken into account. If the
S3 ED 50 %, 10min
Motor
40°C
n. s.
S3 ED 60 %, 10min
Motor
n. s.
40°C
S1
Wall (ve ntilated)
47°C
45°C
Bus specification
PROFINET IO Max. 100 MBaud Cable Min. Ethernet CAT-5 Electrical isolation 500 V
Max. cable length 100 m between two
eff
modules Bus connection Screw terminals Shield Direct to PE bus termination performed automat ica lly PE connection via PE screw connection Status display 6 LEDs in the terminal box Topology Star, tree, ring, linear bus
Performance
Update interval for process data between module and frequency inverter ≈ 5 ms Parameter read access on the frequency inverter ≈ 25 ms Parameter write access with storage in EEPROM ≈ 70 ms Cycle times ≥ 1 ms
Pos: 7 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/Derati ng [SK CU 4-PNT] @ 4\mod_1385651939979_388.docx @ 107331 @ 5 @ 1

Derating

NOTICE
Derating
S3 ...) and the installation type (wall-mounting, motor -mounting) of the frequency inverter as well as the type of permissible ambient temperature is exceeded, the module may heat up to an impermissible extent and switch off
with an error message (E104.0).
Maximum ambient temperature *
Operating mode Installation type SK 180E / SK 190E SK 2xxE
S1 Motor 25°C 27°C
S1 Wall (unventilated) 37°C 39°C
* The limits of the frequency inverter must not be exceeded (refer to the frequency inverter manual).
Pos: 8 /Technis c h e Inf ormation en/ SK xUx - Bus - Er weiterung en/PROFIN ET IO/Mer kmal e [PNT Allge mei n] @ 4\mod_1385365458675_388.docx @ 106301 @ 5 @ 1
2 / 8 TI 275271015 - 4913
PROFINET IO Bus module – SK CU4-PNT
Isochronous real time communication of synchronised
Transmission and receiver cables are automatically
diagnosis socket on the device (if available) and possibly

Module features

Communication RT (Real Time)
à Real time communication of process data
IRT (Isochronous Real Time)
à process data
Addressing Automatic address assignment via IO controller using DCP
(Discovery Configuration Protocol) Data transfer via Switched Ethernet Autonegotiation Negotiation of transfer parameters Autocrossover
crossed in the switch as necessary Conformity classes CC-B, and CC-C Access for NORD diagnosis tool via
via frequency inverter and
Ethernet protocols UDP or TCP/IP
Pos: 10 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - Systemübergreifend/Montage [SK CU4-xxx] @ 3\mod_1371811235059_388.docx @ 79455 @ 5 @ 1

Installation

Installation location Within the connection unit of a frequency inverter (SK 180E, SK 190E, 2xx E) Mounting with screw fastenings
Pos: 13 /T echnische I nformatio nen/SK xUx - Bus - Erweit erungen/Al lgemein - S ystemüberg reifend/Ans chlüsse [ SK CU4 - ...] @ 4\ mod_1378291237620_388.docx @ 93067 @ 5 @ 1
TI 275271015 - 4913 3 / 8