This document is only valid in combination with the operating instructions for the relevant drive unit. All of the
up of this module and the drive unit is only available under these
Technical Information / Datasheet
Pos: 1 /Tec hnische Inf ormation en/Zubehör/ Platine_P egelwandl er_Contelec tgeber/Pl atine Pegel anpassung HTL - RS42 2 / 1855209 0 / Basisi nformation en [ - HTL-RS422] @ 4\mod_138028803 7127_388.docx @ 100101 @ 555 @ 1
Level adapter PCB HTL - RS422
Part number: 18 552 090
Level converter HTL – RS422
NOTICE
information that is relevant for a safe startconditions.
Validity of the document
Scope of delivery
1 x Module PCB, lacquered
Accessories required
1 x Mounting kit
OBW MOUNTING KIT
PCB 185520xxx
(Part No. 18552160)
Usage area
The module, which is inten ded for installat ion in th e motor ter m inal box, is used t o convert H TL or TTL
signals into complementary signals with RS422 levels. With this form of signal, th e pr oba bi lity of errors
in data transmission is c onsiderab ly reduce d. Use of this m odule is rec omm ended for cable le ngths in
excess of 30 m.
Technical data
Module
Ambient temperature -25°C … +75 °C Weight 20 g
Protection class IP00 Dimensions [mm] L x W x H: 46 x 35 x 22
Electrical data
Electrical connection Spring terminals Cross-section 20-16 AWG
Input voltage 10 … 30 V DC Connection terminals (0.5 – 1.5 mm2)
Input level "0" ≤ 0.8 V Power consumption 10 mA (own consumption)
Input level "1" ≥ 2.4 V Max. frequency 100 kHz
Max. output voltage
Typical output current: 45 mA (120 Ω) RS422 1200 m
Maximum: 100 mA Frequency inverters 500 m at 100 kHz
+ 5.5 V
Max. cable lengths
Level adapter PCB HTL-RS422
V1.0 Erstausgabe / first issue 4813 Rck TI 18522090 GB
version reason for change(s) issue name document speech
Level adapter PCB – HTL-RS422
Insert the M4 screws (1) with toothed washers (2) from above into
Signal delay Tests
Rising flank 250 ns EN61000-4-2 ESD 4 kV contact discharge
Falling flank 750 ns 8 kV air discharge
Protection EN61000-4-4 Burst 1 kV signal cables
Power supply Reverse polarity protected 2 kV power supply
Outputs Short-circuit protected EN61000-4-5 Surge 1 kV signal cables
Overtemperature Switch-off at 150°C 2 kV power supply
Pos: 3 /Tec hnische Inf ormation en/Zubehör/ Platine_P egelwandl er_Contelec tgeber/Mo ntage [Plat ine Pegel anpassung ] @ 4\mod_1380536273119_388.docx @ 100204 @ 5 @ 1
Installation
Installation location In motor terminal box
Mounting Double screw fastening with installation kit (Part No.: 18552160)
Installation kit consisting of: 2 x M4 screws
Illustration of installation
kit
Tools Slot-head screwdriver 0.6 x 3.5
The PCB is installed in an adequately dimensioned motor terminal box. Installation in a one-piece terminal box
(EKK) is not possible.
1.
the holes provided (3).
2. Put 3 plastic washers (1) onto each screw from the underside.
3. Screw the PCB into the terminal box.
Pos: 4 /Tec hnische Inf ormation en/Zubehör/ Platine_P egelwandl er_Contelec tgeber/Ans chlüsse [ Platine Peg elanpass ung HTL ... ] @ 4\mod_1380537501717_388.docx @ 100255 @ 5 @ 1
2 TI 18522090 - 4813