View of PCS-1 ...........................................................................................................22
Page 4Nokia Mobile Phones Ltd.Issue 1 03/01
Page 5
NSB-5
PAMS Technical DocumentationService Tools
Battery Adapter BDC-3
The Battery Adapter BDC-3 is used, along with an external battery capacity meter, to
check battery capacity.
Note that Li-ion batteries have an internal protection circuit to prevent deep discharge.
Product Code
Battery Adapter BDC-3:0770083
View of BDC-3
Issue 1 03/01Nokia Mobile Phones Ltd.Page 5
Page 6
NSB-5
Service ToolsPAMS Technical Document ation
Service Battery BBD-3
The Service Battery BBD-3 is used in place of the phone’ s normal battery during service,
to supply a controlled operating voltage to the phone for current and charger calibration,
and also is required when flashing the phone.
Note that the cable SCB-3 (0730114) also is required for charger calibration.
Product Code
Service Battery BBD-3:0775071
View of BBD-3
Page 6Nokia Mobile Phones Ltd.Issue 1 03/01
Page 7
NSB-5
PAMS Technical DocumentationService Tools
Module Jig MJS-8
The Module Jig MJS-8 is used for component level repair of the system/RF module. *
Product Code
Module Jig MJS-8:0775170
View of MJS-8
* Connect the External Antenna Cable XRC-1B, Service Cable SCH-5, and the DC Cable
PCS-1 to the MJS-8 jig.
The Service Cable SCH-5 can be replaced by the DAU-9P cable.
Note: The nominal supply voltage for MJS-8 is +4.1V. The supply voltage must not
exceed +6.0V.
Issue 1 03/01Nokia Mobile Phones Ltd.Page 7
Page 8
NSB-5
Service ToolsPAMS Technical Document ation
Audio Test Probe MP A-1
MPA-1 is an Audio Test Probe used for testing the microphone signal. MPA-1 is used in
conjunction with Module Jig MJS-8.
Product Code
Audio Test Probe MPA-1:0775169
View of MPA-1
MPA–1
Audio Test Probe
MJS–8
Module Jig
Page 8Nokia Mobile Phones Ltd.Issue 1 03/01
Page 9
NSB-5
PAMS Technical DocumentationService Tools
Flash Loading Adapter FLA-5 (Sales Pack)
The Flash Loading Adapter FLA- 5 is used with the Service Battery BBD-3 and Service
Cable SCH-5. Power is supplied to FLA-5 from the Flash Security Box TDF-4 via the DC
Cable PCC-1B (the PCC-1B cable can be replaced with a Travel Charger ACH-6), and is
connected to the Flash Prommer FPS-4S with the cable AXS-5.
The sales pack includes:
- Flash Loader Adapter FLA-50770085
- Service Cable SCH-50730098
- D15 - D15 Cable AXS-50730091
- Installation software for FPS-48400041
Product Code
Flash Loading Adapter FLA-5:0080178
View of FLA-5
Issue 1 03/01Nokia Mobile Phones Ltd.Page 9
Page 10
NSB-5
Service ToolsPAMS Technical Document ation
Flash Prommer FPS-4S (Sales Pack)
The Flash Prommer FPS-4S is used to update the main software of the phone. Updating is
done by first loading the new MCU software from the PC to the flash prommer, and then
loading the new SW from the prommer to the phone. When updating more than one
phone in succession, the MCU software only needs to be loaded to the prommer once.
The sales pack includes:
- Charger ACL-3E0680015
- Printer Cable0730029
- D9 - D9 Cable AXS-40730090
- Installation software for FPS-48400041
Product Code
Flash Prommer FPS-4S:0080178
View of FPS-4S
Page 10Nokia Mobile Phones Ltd.Issue 1 03/01
Page 11
NSB-5
PAMS Technical DocumentationService Tools
Security Box TDF-4
The Security Box TDF-4 is required for updating MCU software and for infrared testing.
Note1:TDF-4 is delivered in de-activated mode. Fill in the enclosed Activation Request
Form and fax it to NMP Salo to get the activation code.
Note2:The infrared module JLP-1 is not included in the TDF-4 sales package.
Product Code
Security Box TDF-4:0770106
View of TDF-4
Issue 1 03/01Nokia Mobile Phones Ltd.Page 11
Page 12
NSB-5
Service ToolsPAMS Technical Document ation
Service Audio Box JBA-4
The Service Audio Box JBA-4 is used between the Service Cable SCH-5, MBUS Cable
DAU-9S, and Audio Cable ADS-1.
Product Code
Service Audio Box JBA-4:0770094
View of JBA-4
Page 12Nokia Mobile Phones Ltd.Issue 1 03/01
Page 13
NSB-5
PAMS Technical DocumentationService Tools
Service Cable SCH-5
The Service Cable SCH-5 is used between the phone and the Service Audio Box JBA-4 (or
modular T-adapter). It also is used between the phone and the Flash Loading Adapter
FLA-5.
Product Code
Service Cable SCH-5:0730098
View of SCH-5
Issue 1 03/01Nokia Mobile Phones Ltd.Page 13
Page 14
NSB-5
Service ToolsPAMS Technical Document ation
Warranty Cable SCH-6
The Warranty Cable SCH-6 is used to connect two phones, and enables transfer of data
(stored numbers, etc.) from one phone to another.
Product Code
Warranty Cable SCH-6:0730099
View of SCH-6
Page 14Nokia Mobile Phones Ltd.Issue 1 03/01
Page 15
NSB-5
PAMS Technical DocumentationService Tools
Audio Cable ADS-1
Audio cable is an adapter routing AF signals (MIC/EAR) from 8-pin modular connector to
two BNC connectors. It is used to connect JBA-4, SCH-5, and DAU-9S.
Product Code
Audio Cable ADS-1:0 730011
View of ADS-1
Issue 1 03/01Nokia Mobile Phones Ltd.Page 15
Page 16
NSB-5
Service ToolsPAMS Technical Document ation
D15 - D15 Cable AXS-5
The D15-D15 Cable AXS-5 is used to connect two 15-pin D connectors (e.g., between
FLA-5 and FPS-4S).
Product Code
D15-D15 Cable AXS-5:0730091
View of AXS-5
Page 16Nokia Mobile Phones Ltd.Issue 1 03/01
Page 17
NSB-5
PAMS Technical DocumentationService Tools
DC Cable PCC-1B
The DC Cable PCC-1B is used to connect FLA-5 and TDF-4.
Product Code
DC Cable PCC-1B:0770053
View of PCC-1B
Issue 1 03/01Nokia Mobile Phones Ltd.Page 17
Page 18
NSB-5
Service ToolsPAMS Technical Document ation
DC Cable SCB-3
The DC Cable SCB-3 is used to connect the Service Battery to the charger connection Vin
of the phone when doing the charger calibrat ion service procedure.
Product Code
DC Cable SCB-3:0730114
View of SCB-5
Page 18Nokia Mobile Phones Ltd.Issue 1 03/01
Page 19
NSB-5
PAMS Technical DocumentationService Tools
External Antenna Cable XRC-1B
The External Antenna Cable is used to connect the transceiver to measuring equipment
during servicing.
Note:Typical attenuation at 900MHz is 0.7 dB.
Typical attenuation at 1800MHz is 0.9 db.
Product Code
External Antenna Cable XRC-1B:0730128
View of XRC-1B
Issue 1 03/01Nokia Mobile Phones Ltd.Page 19
Page 20
NSB-5
Service ToolsPAMS Technical Document ation
MBUS Cable DAU-9S
The MBUS Cable DAU-9S has a modular connector and is used with the Service Audio
Box JBA-4 or the modular T-adapter.
Product Code
MBUS Cable DAU-9S:0730108
View of DAU-9S
Page 20Nokia Mobile Phones Ltd.Issue 1 03/01
Page 21
NSB-5
PAMS Technical DocumentationService Tools
MBUS Cable DAU-9P
The MBUS Cable DAU-9P has a phone system connector and is used between the phone
and external devices.
Product Code
MBUS Cable DAU-9P:0730109
View of DAU-9P
Issue 1 03/01Nokia Mobile Phones Ltd.Page 21
Page 22
NSB-5
Service ToolsPAMS Technical Document ation
Power Cable PCS-1
The Power Cable PCS-1 is used toconnect the module jigs JBT-1 and JBS-19 to an external power supply.
Product Code
Power Cable PCS-1:0730012
View of PCS-1