Precaution
Safety Installation Instructions
When installing telephone wi ring, basic safety prec autions shou ld always be f ollowed to reduc e the risk
of fire, electric shock and injury to persons, including the following:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
3. Never touch non-insulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
4. Use caution when installing or modifying telephone lines.
Installation Precautions
This set is exclusively made for wall mounting only. Avoid installing in the following places.
(Doing so may result malfunction, noise or discoloration.)
1. In direct sunlight and hot, cold, or humid places. (Temperature range: 0°C-45°C/32°F- 113°F)
2. Sulfuric gases produced in areas where there are thermal springs, etc., may damage the
equipment or contacts.
3. Places in which shocks or vibrations are frequent or strong.
4. Dusty places, or places where water or oil may come into contact with the unit.
5. Near high-frequency generating devices such as sewing machines or electric welders.
6. On or near computers telexes, or other office equipment, as well as microwave ovens or air
conditioners, (It is preferable not to install in the same room with the above equipment.)
7. Install at least 1.8 m (6 feet) from radios and televisions. (both the main unit and a key telephone)
8. Do not obstruct area around the main unit (for reasons of maintenance and inspection - be
especially careful to allow space for cooling above and at the sides of the main unit).
Wiring Precautions
Make sure to keep the following instructions when wiring.
1. Do not wire the telephon e cable in p arallel with an AC po wer source, computer, telex, etc. If the
cables are run near t hose wires, shi eld the cables with metal tubing or use shielded ca bles and
ground the shields.
2. If cables are run on the floor, use protec tors or the like to protect the wir es where they may be
stepped on. Avoid wiring under carpets.
3. Avoid using the sam e power supply outlet for computers, telexes , and other office equipment.
Otherwise, the TX-Z 308's system operation m ay be interrupted b y the induction n oise from such
equipment.
4. Please use one pair te lephone wire for extens ion connection of ( telephone) equipment such as
standard telephones, answering machines, etc., except key telephones.
5. The AC cord must be plugge d off during wiring. After a ll the wiring are com pleted, plug the AC
cord into an AC outlet.
6. Mis-wiring may cause the system to operate improperly.
7. If an extension does not oper ate properly, disc onnect the telephone f rom the extension l ine and
then connect again, or plug off the AC cord of the system and then on again.
8. The TX-Z 308 is equipped with a 3-wire grounding type plug. This is for safety. If you are unable to
insert the plug into the outlet, contact your electrician to replace your obsolete outlet.
9. Use twisted pair cable for Trunk line connection.
10.Trunk Lines shou ld be instal le d with li ght ing pr otec t ors . (Ask your dealer)
11.The aerial distribution wiring is not allowed.