Troubleshooting
POSEIDON 5 NEW-NA5_en_Ver.1.0_20/12
44
E
Fault Cause Remedy
When the cleaner is switched
on the motor buzzes without
starting.
The main voltage is too low
or there is a phase failure
(3 ph model).
The pump is blocked or
frozen.
Incorrect cross-section or
lenght of the extension lead.
Have the electrical
connections checked.
Pump needs service
(see part ”F”).
Use lead with correct cross
section and length.
The motor switches off.
The overload protection has
been activated due to
overheating or overloading
of the motor.
High pressure nozzle is
dirty.
Check that the main voltage
and the cleaner voltage are
the same.
Switch off the cleaner and
allow it to cool for at least
3 minutes.
Change the high pressure
Cleaner starts / stops by itself.
Leakage on high pressure
side.
Locate the leak and repair
it. (See next page).
No detergents drawn in.
Injector is dirty or suction
hose is blocked.
Detergent container empty.
The cap on the nozzle is
not set at low pressure.
Clean.
Top up/change the
container.
Turn cap of the
FlexoPower nozzle towards
”CHEM” up to the stop.
Working pressure too low.
Working pressure too low and
loud noise comming from
pump .
- Suction - and pressure
valves leaking.
- Piston U-sleves in pump
worn.
- Piston stocked in pump.
Replace parts.
Check pump for
damaged parts —
demount and
reassemble pump
housing with the right
torque.
General failures.