Nice HSCU1 Instructions And Warnings For Installation And Use

Nice HSCU1
Instructions and warnings for installation and use
Home security control unit
0682
Content
1 – WARNINGS AND GENERAL PRECAUTIONS . . . . . . . . . . . . . . . . . . . 2
1.1 - General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 - Installation warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 – PRODUCT DESCRIPTION AND INTENDED USE . . . . . . . . . . . . . . . . 2
2.1 - Radio communication system between devices . . . . . . . . . . . . . . 2
TECHNICAL GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 – DESIGNING AN ALARM SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1 - How to divide up the home and zones to be protected . . . . . . . . . 4
3.2 - Where to position the alarm system components . . . . . . . . . . . . . 4
3.3 - Elements in the Nice Home Security alarm system . . . . . . . . . . . . 7
3.4 - Main features of the Nice Home Security alarm system . . . . . . . . . 9
4 – INSTALLATION: the control panel and accessories . . . . . . . . . . . . . 10
4.1 - Set-up of system components for configuration . . . . . . . . . . . . . 10
4.2 - Preliminary installation checks and product application limits . . . 10
4.3 - Control unit description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.4 - INSTALLATION: Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.5 - Door and window opening detector (model HSDID11) . . . . . . . . 14
4.6 - Infrared detector with volumetric lens (model HSDIM11) . . . . . . . 15
4.7 - Infrared detector with vertical curta in lens (model HSDIM12) . . . .16
4.8 - Volumetric detector of glass breakage (model HSDID01) . . . . . . . 17
4.9 - Fine combustion powder detector (model HSDIS01) . . . . . . . . . . 17
4.10 - Flooding detector (model HSDIW01) . . . . . . . . . . . . . . . . . . . . . 18
4.11 - 4-channel alarm transmitter (model HSTX4) . . . . . . . . . . . . . . . 18
4.12 - 8-channel radio transmitter (model HSTX8) . . . . . . . . . . . . . . . . 18
4.13 - Control keypad (model HSKPS) . . . . . . . . . . . . . . . . . . . . . . . . 19
4.14 - Indoor siren (model HSSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.15 - Outdoor siren via radio (model HSSO) . . . . . . . . . . . . . . . . . . . . 20
4.16 - External siren with wired connections (model HSSOC) . . . . . . . 21
5 – ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.1 - Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.2 - Connections on the control panel . . . . . . . . . . . . . . . . . . . . . . . . . .
(models HSCU1GC and HSCU1C only) . . . . . . . . . . . . . . . . . . . . . . . . 22
5.3 - Connections on siren model HSSOC . . . . . . . . . . . . . . . . . . . . . 22
6 – CONTROL PANEL PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.1 - Initial start-up and configurations . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2 - Programming menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7 – PRODUCT MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.1 - Replacing the batteries (control panel and accessories) . . . . . . . 29
8 – TROUBLESHOOTING... (troubleshooting guide) . . . . . . . . . . . . . . . 31
DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
9 - OPERATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.1 - Tips when using the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.2 - Operations available to the user . . . . . . . . . . . . . . . . . . . . . . . . . 32
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
EC DECLARATION OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . 36
1
1.1 - General warnings
This manual contains important instructions and warnings for personal safety during installation: therefore read all instructions before proceed­ing with installation. Keep this manual in a safe place for future use. Further
information can be found on the web site: “www.niceforyou.com”.
• If in doubt during installation, do not attempt further operations and contact a NICE service centre.
• Use of these products for applications other than as specified in these instructions is strictly prohibited.
• Never make any modifications to parts of the product if not envisaged in this manual; operations of this type will lead to malfunctions. NICE declines all lia­bility for damage caused by modified products.
• According to the specific application, check whether additional products are required, such as detection or signalling devices.
• During installation and use of the product, ensure that no foreign bodies (solids or liquids) penetrate any open devices.
• The product packaging material must be disposed of in full observance of current local legislation.
Manufacturer liability: Nice declines all liability for faults caused by incorrect installation, failure to perform maintenance, or improper use. Nice also declines liability for incorrect or incomplete operation of the product or failure to detect intrusion.
Guarantee (summary of terms): Nice guarantee company products against concealed defects for a period of 3 years as of the date of manufacture. The guarantee applies to direct pur­chasers from Nice. No guarantee is envisaged for the end user, who in the event of faults must contact the specific installer or retailer.
Exclusions from the guarantee: the guarantee does not cover aesthetic parts, parts subject to normal wear or normal consumables, such as batteries.
1.2 - Additional warnings for mains-powered appliances
• This manual is aimed exclusively at technical personnel qualified for installation.
• Considering the hazards that may occur during system installation and use, maximum safety is only ensured if the product is installed in strict observance of current legislation, standards and regulations.
WARNINGS AND GENERAL PRECAUTIONS
1
• Before accessing internal terminals of the product, all power circuits must be disconnected.
• If an automatic circuit breaker trips or a fuse blows, identify and eliminate the fault before restoring normal operating conditions.
1.3 - Installation warnings
• Ensure that all material to be used is in perfect condition and suitable for its intended use.
• Ensure that the radio frequencies used by the product are suitable for use in alarm systems adopted in the region of installation.
• The individual parts are designed according to the following environmental classes:
- Class II environment: general indoor use; temperature range -10 - + 40°C, average humidity 75% (condensate free)
- Class III environment: protected outdoor use; temperature range -25 ­+50°C, average humidity 75% with peaks of 30 days per year between 85 and 95% (condensate free)
• Before proceeding with installation, check the product environmental class as specified in the chapter “Technical specifications”.
• Refer to the chapter “Technical Specifications” to check that the radio range of the devices is greater than the physical distance between the various prod­ucts.
• Ensure that the various devices (sensors, control unit, etc.) are located in areas protected against the risk of impact, and that the fixing surfaces are sufficiently solid.
• Do not place system components near sources of heat to avoid potential damage.
• Each sensor has a specific operating principle: check the relative instruction manual for warnings when selecting the suitable location.
This control unit and relative accessories are part of the alarm system “Nice Home Security”, designed for the protection of residential spaces. Any use
other than as described in this manual is strictly prohibited!
The alarm system Nice Home Security is not to be considered simply a home burglar alarm, as it is able to detect a variety of events thanks to special sen­sors: intrusion, break-in attempts (impact-vibration sensor), fire risks (smoke detector) and water leaks (flooding sensor)
The different alarm situations can be indicated locally with audible signals (indoor or outdoor sirens), with voice messages or remotely via telephone calls or text messages.
The system offers maximum installation flexibility: the various elements can interact totally via radio, without the need for any electrical connections or, in some cases, with just short connections (for example the electrical contact of the door may be connected to the volumetric sensor located in the corner of the room) or may be partially wired where the main elements (control unit, siren, telephone dialler) use conventional electrical connections.
Though based on communication via radio waves, the system guarantees total reliability of communication between devices, thanks to the use of 2 separate frequencies (433 and 868 MHz); communication between the main elements is also bidirectional, i.e. when a device sends a command, it waits to receive the confirmation response.
PRODUCT DESCRIPTION AND INTENDED USE
2
2.1 - Radio communication system between devices
The radio system Nice Home Security offers increased flexibility and simpler installation with respect to traditional systems using fixed wiring. In any event, to ensure radio communication without interference (and thus guaranteed), the following factors must be taken into account:
• Radio transmission inside buildings
Radio signals are electromagnetic waves, which when emitted by a transmitter unit are propagated in the surrounding area through to the receiving unit. On this route, the radio signal may encounter obstacles, which depending on the construction material, may weaken signal power. Common residential buildings may be made up of different materials: Table 1, provides information on the range of radio signals inside buildings, considering both the construction mate­rials used and the mounting position.
• Sources of electromagnetic disturbance
Sources of electromagnetic disturbance are natural sources (terrestrial or solar), occasional sources (e.g. lightning), or intentional artificial sources; the latter are those most frequently present in modern environments. Table 2, provides infor- mation on possible disturbance and relative risks associated with communica­tion of other systems. As regards the frequencies used by the system, the use of devices with continuous transmission (100%) is prohibited unless below cer­tain power classes. However, illegal devices that operate with continuous trans­mission are commercially available. The use of a radio system at dual frequen­cy avoids the risk of disturbance unless the specific disturbance covers both frequencies.
In open spaces (outdoors)
Walls in plasterboard/wood
Walls in brick or concrete
Walls in reinforced concrete or ceilings
Walls in metal
approx. 100 m
approx. 50 metres, through a maximum of 5 walls
approx. 30 metres, through a maximum of 3 walls
approx. 20 metres, through a maximum of 1 wall or ceiling
not admitted; metal walls constitute virtual total shielding
TABLE 1
MATERIAL ESTIMATED MAXIMUM RANGE
2
Alarm (status) Status of the control unit, which differs according to the envisaged cause of alarm (see audible signals and alarms)
False alarm False alarm, caused by defect and/or fault of one or more appliances
Improper alarm Alarm caused by incorrect installation, technical restraint of appliances or external cause
“Panic” alarm Type of alarm and relative signal implemented to draw attention and prevent possible inadvertent actions
Burglar alarm Type of alarm and relative signals implemented in a situation of danger where it is preferable not to activate sirens, for
example calling the police forces or when different aid is required (calling a doctor)
Technological alarm Different and specific type of alarm for detectors of smoke, flooding or other hazardous events
Alarm (zone) Group of detectors, activated/deactivated together, for example the sleeping area may be considered as one zone.
Each detector can be programmed to belong to one zone only
24 hour Alarm Type of zone activated at all times; panic, burglar and technological alarms are all of this type
And Control unit function used to reduce the number of improper alarms, enabling the programming of two detectors in the
same area and generation of the alarm status only if both transmit an alarm signal (within 30 seconds of one another)
Antiduress Keypad function that enables shutoff of an alarm by entering a different code from the normal version, but which acti-
vates the robbery alarm at the same time
Detector disable Operation to disable a detector through to subsequent reset (due to a fault or other cause)
Domotics System designed to automate appliance commands or devices (open/close doors, turn on lights etc.) according to set
rules, for example when specific events occur, such as lights turning off or shutters closed when an alarm is activated.
Tampering Attempt to deactivate a device, for example by opening an appliance casing or remove it from a fixture point.
Event log Control unit facility to record to last 200 operations performed and to review events on the display
Pre-alarm (control unit status) Control unit status prior to actual alarm, for example caused by detectors programmed with an alarm delay
Pre-alarm (siren status) Siren status before activation (emission of beeps repeated for approx. 10 seconds)
Alarm delay Interval between transmission of detector and alarm status: programmable for each detector
Detector (or sensor) Appliance designed to signal intrusion, transit, opening of doors/windows and any other event that may be a source of
a hazard or alarm
Perimeter detector Detector applied on doors or windows to protect the building “perimeter”
Volumetric detector Indoor detector controlling the entire volume of a room
Test (status of…) Control unit status that blocks activation of alarms, for example for test procedures or battery replacement
“Panic” zone Type of zone activated at all times; used when necessary for activation of external sirens and telephone calls via a key
on the remote control or keypads
Burglar zone Type of zone activated at all times; used when only telephone call activation is necessary (silent alarm) via a key on the
remote control or keypads
Technological zone Type of zone activated at all times; used to generate a specific alarm caused by detectors of smoke, flooding or other
hazardous events
TECHNICAL GLOSSARY
Radio and television transmitters
Variable speed motors
UPS units
Switching power supply units
Other devices on the same frequency, used < 1%
Other devices on the same frequency, used < 100%
continuous
continuous
continuous during phase of use
continuous during phase of use
occasional
continuous (use prohibited)
high, if close
low, during use only
medium, during use only
medium, during use only
very low
very high
TABLE 2
DEVICES TYPE OF DISTURBANCE PROBABILITY OF DISTURBANCE
3
To obtain a perfectly operational and efficient system in terms of the intended use, the system must first be designed “at the table”, before proceeding to the operating phases described in this manual. In particular it is fundamental to establish the number and type of detectors to be used, and their relative loca­tion according to the specific actions required. To ensure a suitable design, a layout of the building should be drawn up where the alarm system is to be installed, specifying the name and position of each device envisaged in the sys­tem. This layout drawing will be useful and also decisive in the system configu­ration phase, for example when the name of each device needs to be memo­rised.
3.1 - How to divide up the home and zones to be protected
The control unit can be programmed to control the entire home concerned or portions of the latter. For this reason, it is important to first divide up the entire area covered by the system into three “intervention zones” (zones A - B - C), assigning each environment to one of the three zones, according to a suitable and functional logic. In the case of single buildings, an initial division logic is one of “concentric cir­cles” (see fig. 1). Using this logic, the user can assign, for example, detectors positioned outside the building to zone A, the perimeter detectors (on doors and windows) to zone B and the detectors inside the building to zone C. This division enables, for example, dissuasion of intrusion attempts by means of voice messages emitted by the siren (in zone A) before entry, or activation of a
DESIGNING AN ALARM SYSTEM
3
siren alarm on the first attempt at break-in via a door or window (in zone B), or calls to the police forces only when the indoor detectors (in zone C) signal intru­sion. Another logic used to divide the areas to be protected is one of “uniform blocks” (see fig. 2). Using this logic, the user can assign, for example, the rooms on the ground floor to zone A, the rooms on the first floor to zone B, and the garage to zone C. This division enables, for example, activation of the alarm in the garage (zone C) while normal activities can continue in the rest of the house.
3.2 - Where to position the alarm system components
To decide on the position of the various components of the system, refer to fig. 3 and also ensure the following conditions:
• Control unit
- The control units operate by transmitting and receiving low power radio sig-
nals (within the limits as specified in the relevant standards), and therefore must be installed in zones that ensure efficient propagation of the signals. Therefore avoid alcoves, metal cabinets, posts and walls in reinforced con­crete; also ensure that there are no large metal surfaces or grids in the vicinity of the control unit, including those embedded in walls.
- The control unit should be positioned at the centre with respect to the other
devices (see also paragraph 2.1 “Radio transmission inside buildings”).
1
zone C
zone B
zone A
zone B
zone A
zone C
2
4
3
- The quality of the radio signal received can be checked on the control unit dis­play (see paragraph 9.2.5 “FIELD METER test”) and if in doubt, test before fix­ing the control unit to the wall. In the case of radio appliances, a change in position of even just a few centimetres can significantly improve signal recep­tion and transmission.
- The control units are equipped with a keypad that enables programming dur­ing installation and daily use of a number of functions, such as activation/ dea­ctivation of the alarm. If these functions are required, the control unit must be located in an accessible position, normally close to the main entrance door.
- If a connection to the telephone line is required, ensure that the relative hook­up is feasible.
- The control units with mains power must be positioned where the relative electrical connection is possible.
• Keypads
For aesthetic reasons or due to electrical connection requirements, if the con­trol unit has to be positioned far from the main entrance door, a keypad should be installed in the vicinity. If there are other entrance points to the home, a keypad should be installed at each access point. The keypads can be wall-mounted or portable (as with a transmitter) if required.
Sirens In the case of isolated buildings, the installation of at least one outdoor siren is
strongly recommended. This should be positioned in a highly visible location (to aid as a deterrent) but in a place difficult to access by vandals/burglars. Although the sirens are adequately protected for outdoor applications, they should be installed in an area protected against direct rain; the ideal location would be under a protruding roof or on a terrace/balcony. The control unit has an incorporated siren, but in large or multi-floor buildings, the addition of one or more indoor sirens is recommended, located in the main rooms. In small apartments, or densely populated areas, an outdoor siren may not be welcome; in this case, one or more indoor sirens may be used to increase the deterrent effect.
• Sensors
The choice of the type of sensor to be used is fundamental, as is the relative position of installation: an incorrect sensor or one positioned in an unsuitable location may not detect intrusion or may generate improper alarm signals. Each type of sensor has a different operating principle; refer to the correct selection criteria for each sensor in Table 3.
HSDID11
HSDID11
HSDID11
HSDID11
HSDIM11
HSDIM11
HSDIM12
HSDIM12
HSDIM12
HSDIS01
HSDIM21
HSDIM22
HSDOM21
HSSI
HSDIW01
HSDIW01
HSCU1GC
HSCU1C
HSCU1G
HSCU1
HSSOC
HSSO
5
6
Door sensor: this is an intruder sensor designed to protect doors or windows, and signals opening of the latter when the magnet is moved away from the
sensor body. The detector is normally mounted on the fixed section of the frame to be protected, on the side opposite the hinge, while the magnet is fitted on the movable section. To increase protection, a second sensor with an NC or pulse type contact can be connected to a terminal (cable detector for rolling shutters). This sensor also has an NO input, which can be used, for example, to connect a flooding sensor.
Sensor with vertical curtain lens: this is an intruder detector designed to protect doors or windows; thanks to its curtain lens it signals the movement of persons present only within the close range in front of the sensor (fig. 4).
The sensor can be “ceiling-mounted”, at the top centre of a door or window (normally between the window and shutter/blind) and in an area protected against adverse weather conditions. The sensor is fitted with a terminal for connection of a second sensor with an NC or pulse type contact (cable detector for rolling shutters). This ensures increased protection, optimising coverage of the area to be protected.
Volumetric sensor: this is an intruder detector designed for the protection of rooms; it signals the movement of persons in the protected area. The sensor can be mounted on a wall, in a corner with the special adaptor and can be set at different angles thanks to the articulated support (accessory not supplied).
Sensor operation is based on the detection of movement of heat-emitting bodies; for this reason, and to avoid improper alarm activation, avoid installation in points subject to currents of hot or cold air. If the sensor is active and animals (hot-blooded) use the room, a suitable position and angle should be select­ed to avoid detection below 50-70 cm from the ground (fig. 5); reduce sensor sensitivity if necessary.
The sensor is fitted with a terminal for connection of a second sensor with an NC or pulse type contact (cable detector for rolling shutters). This ensures increased protection, optimising coverage of the area to be protected.
Volumetric sensors for large environments: normal volumetric sensors have a sensitive range that is able to cover most standard-size rooms. In the case of large rooms, special sensors are available with surface area coverage of up to 12 m with 120° opening. This type of sensor has a provision to adjust sen­sitivity to enable precision settings according to the dimensions of the protected area.
Dual technology sensors: these are intruder detectors designed for the protection of rooms; they use 2 different technologies (infrared and microwave) to detect the movement of persons in the protected area. Infrared technology detects heat emitted by bodies, while microwave technology (Doppler effect) detects the movement of objects (also cool). The combination of the two technologies achieves maximum efficiency with the minimum risk of improper alarms.
Sensors for outdoors: sensors are usually designed for protected indoor environments. These operate correctly within a relatively restricted temperature range and are not completely protected against rain. Special sensors are available for outdoor use, with a temperature range from -25 to +50°C and com­plete protection against adverse weather conditions. All these sensors have a provision to adjust sensitivity, to enable precision settings according to the dimensions of the protected area and the avoidance of improper alarms caused, for example, by normal moving objects (tree branches), small animals, insects etc.
Glass breakage sensor: this sensor detects the breakage of glass (normal glass, double glazing). The detector is fitted with a microphone specially tuned to recognise the specific noise of glass when it breaks; therefore take great care as the sensor may detect other events that produce a similar noise (for example a tumbler falling and breaking on the floor). Activation of this sensor is only recommended if there are no persons in the relative zone who could pro­duce similar sounds.
Also appliances able to generate sudden pressure surges in rooms (air conditioners, fans) may generate improper alarms.
Sound-absorbing materials (such as curtains and carpets) may reduce the sensitivity of the sensor.
The device is optimised with a factory-setting and may not be modified.
To ensure optimal detection, the device must be installed in rooms with an area of 20 to 30 square metres, at a distance of 3 to 6 m from the glass to be pro­tected and at a height of approx. 2 m.
Installation is not recommended in areas with dimensions of less than 10 m
2
, in excessively humid environments (bathrooms or kitchens) and in garages with
large metal doors. These conditions can prove critical and may generate improper alarms.
Fine powder detector: this is a detector of fine combustion powder (mist or smoke effect) designed for residential applications. A photodiode detects opac­ity of the air and signals the alarm directly on site (by means of a buzzer) and also via radio to the control unit. It is a sensor able to detect this event on a max­imum surface area of 6 x 6 m, and must be positioned on the ceiling at the centre of the area to be protected. Smaller rooms that are not square, such as corridors, require the use of more than one detector.
Flooding sensor: this sensor detects flooding caused by water leaks. It is wall-mounted, perfectly flush with the floor surface (the internal sensor is raised by approx. 1 mm from the ground) and positioned in the zone most subject to the risk of water leaks, such as next to a sink or washing machine.
If the floor is not level, the sensor should be placed at the lowest point of the room. The sensor is connected to the NO input of one of the compatible detec­tors (for example HSDID11).
TABL E 3
4
123 456 89 107
2,5
1,5 1
123 456 89 107
0,5
2
2,5
1,5 1 0,5
2
5
7
Control unit
The control unit is the core of the system; it receives information from the detectors, keypads and transmitters and, according to its status, generates an audible alarm (siren) or sends signals on the fixed or mobile telephone net­work. It has an incorporated siren for prompt signalling in the event of intrusion. The integrated keypad is used to configure the system and may also be used as an internal control device. The control unit is equipped with tele­phone diallers to enable connection between the protected location and the outside world, also at great distances. In the event of an alarm, it automatically sends a voice warning message to the pre-set telephone numbers: own­er, police forces, etc. The GSM version also enables the unit to send text messages. The operating mode can also be reversed, i.e. commands can be sent to the control unit via the telephone.
The models available are:
HSCU1GC Control unit for combined alarm systems, wired and via radio, mains powered at 230 Vac. Equipped with PSTN and GSM telephone diallers
HSCU1C Control unit for combined alarm systems, wired and via radio, mains powered at 230 Vac. Equipped with PSTN telephone dialler
HSCU1G Control unit for alarm systems via radio, battery powered Equipped with PSTN and GSM telephone diallers HSCU1 Control unit for alarm systems via radio, battery powered Equipped with PSTN telephone dialler
3.3 - Elements in the Nice Home Security alarm system
Transmitters
These represent the most practical and simple means of activating and deactivating the alarm system both inside and outside the rooms; they enable both partial and total activation of the system and the transmission of emergency signals.
The models available are:
HSTX4 4-channel bidirectional radio transmitter for alarm systems
HSTX8 8-channel bidirectional radio transmitter (4 channels for alarm systems and 4 for automation control)
Detectors
The detectors serve to control objects and the environment in which they are installed, and to transmit events to the control unit. For efficient control, they must be positioned at strategic points of the room, doors, windows, shutters, porches etc. The types of detectors are classified as follows:
- perimeter, for opening of doors, windows, shutters
- perimeter, via the “vertical curtain” detector
- volumetric, for the detection of presence inside the area covered by the sensor
- dual technology, a combination of infrared and microwave
- outdoor, designed for the protection of external areas, porches, verandas, gardens etc.
- special, for the detection of flooding, fine combustion powders (smoke), glass breakage etc.
Up to 99 detectors via radio can be used or double this number if programmed in pairs, with the “AND” function. Control units with wired connections are fit­ted with 6 inputs on detectors with wired connections, for association with the zones A - B - C as required.
The models available are:
HSDID11 Magnetic contact detector with input for NO contacts and one for NC contacts (also with pulse count); single or differentiated alarm.
Intruder sensor
HSDIM11 Infrared detector with volumetric lens with input for second contact (NC or pulse count); single or differentiated alarm. Intruder sensor
HSDIM12 Infrared detector with curtain lens and input for second contact (NC or pulse count); single or differentiated alarm. Intruder sensor
HSDIM21 Infrared detector with volumetric lens for indoor application, in protected areas up to 12 m with 120° opening.
With sensitivity adjustment, immediate alarm or alarm on second pulse, protection against opening and removal
HSDIM22 Volumetric detector with dual technology, infrared and microwave radar, for indoor application, in protected areas up to 12 m with 90°
opening. With sensitivity adjustment, immediate alarm or alarm on second pulse, protection against opening and removal.
HSDOM21 Volumetric detector with dual technology, infrared and microwave radar, for outdoor application, in protected areas up to 12 m with 90°
opening. With sensitivity adjustment, immediate alarm or alarm on second pulse, protection against opening and removal
HSDID01 Volumetric detector of glass breakage
HSDIS01 Fine volatile combustion powder detector
HSDIW01 Flooding detector
HSDID11 HSDIM11 HSDIM12 HSDID01 HSDIS01HSDIM21 HSDIM22 HSDOM21 HSDIW01
HSCU1GC
HSCU1C
HSCU1G
HSCU1
HSTX8
HSTX4
Sirens
The dissuasion devices (sirens), with or without luminous indicators (flashing light) are the main elements of dissuasion in the alarm system. The siren scares and dissuades the intruder, while the flashing light (if fitted) enables illumination of the area where the alarm trips.
The models available are:
HSSI Indoor siren via radio Sound power 114 dB
HSSOC Outdoor siren with cable connection to control unit Sound power 116 dB, with built-in flashing light
HSSO Outdoor siren via radio, bidirectional and dual band. Sound power 116 dB, with built-in flashing light
HSSOV Board for voice messages on HSSE siren
Actuators
The alarm system Nice Home security, as well as being an alarm for the building, is also able to interact with other devices for domotic management of the environment. By means of special actuators, other devices can be controlled, such as lights, gate opening, shutters etc.
The models available are:
HSTT2L Miniaturised single channel radio receiver for the control of electrical equipment (lights, motors,
solenoid valves etc.) compatible with the HS alarm systems
HSTT2N Miniaturised 2-channel radio receiver, specifically for the control of electric motors in 2 directions
(open-close) for shutters and rolling shutters compatible with the HS alarm systems
Repeater
This is a radio signal check and repetition device with HS protocol. It has an input for auxiliary alarm signals and function to indicate a mains power failure.
The models available are:
HSRT Signal repeater
Telephone modem
This is a modem to interface between the USB port of a PC and PSTN telephone networks. With the software supplied, this enables remote management of alarm control units connected to the PSTN telephone network.
The models available are:
HSMO Telephone modem for remote connection to control units fitted with PSTN telephone dialler
The combination of all these elements enables complete supervision of all functions in the home.
Keypads
The keypad enables control of the entire system or a specifically designated area. It communicates with the control unit and provides specific information such as: “system status”, “alarms”, “faults”, “inputs open” and so on.
The models available are:
HSKPS Bidirectional dual band keypad, for control of alarm system and automation control systems
HSSU1 Table-top support for HSKPS keypad
HSSOC
HSSO
HSTT2L
HSTT2N
HSKPS
HSSI
HSRT
HSMO
HSSU1
8
HSSOV
3.4 - Main features of the Nice Home Security alarm system
To exploit the Nice Home Security alarm system to the full, the user needs to know all the features to ensure correct configuration of the entire system according to specific requirements. This section describes the general opera­tion of the control unit and system: operation depends on the devices present and type of settings made during installation.
• Types of alarm
There are different types of alarm:
- Pre-alarm status: the control unit emits a pre-alarm voice message.
- Outdoor alarm: the control unit emits an outdoor pre-alarm voice message
via the sirens.
- General alarm: activation of all sirens for 3 minutes and dialling of all tele­phone numbers envisaged for this type of alarm.
- Panic alarm: when the system is enabled, this activates all sirens for 3 min­utes and dialling of all telephone numbers envisaged for this type of alarm; when the system is partially enabled or disabled, this only activates the sirens via radio.
- Burglar alarm: dialling of all telephone numbers envisaged for this type of alarm.
- Technological alarm: the control unit emits an intermittent audible signal for 15 seconds and dials all telephone numbers envisaged for this type of alarm.
- Tampering alarm: with the system enabled, this generates a “general ala ­rm”; when the system is partially enabled or disabled, this activates an in ter ­mittent audible signal for 3 minutes and dials all telephone numbers envis­aged for this type of alarm.
• Zones
– Three intruder alarm zones are envisaged: zones A, B and C, which respond
dif ferently according to whether the “outdoor alarm” function is programmed or not.
With Outdoor alarm: Yes
Zone A, suitable for outdoor detectors that generate an “outdoor alarm” Zone B, suitable for outdoor detectors that generate a “general alarm” Zone C, suitable for indoor detectors that generate a “general alarm”
With Outdoor alarm: No
Zone A, suitable for perimeter detectors, for example on the ground floor, that generate a “general alarm”
Zone B, suitable for perimeter detectors, for example on the first floor, that generate a “general alarm”
Zone C, suitable for indoor detectors that generate a “general alarm”
– As well as alarm zones A, B and C, which can be activated or deactivated as
required; other constantly active zones are also available (24 hour zones)
Accessory alarm zones, always active
“Panic” zone, activated in the event of necessity via the remote control or keypads
“Burglar” zone, activated in the event of necessity via the remote control or keypads
“Technological” zone, activated by the relative detectors of hazardous events, smoke, flooding etc..
• Alarm activation/deactivation
The following can be used to activate/deactivate the alarm:
- up to 32 bidirectional transmitters, with 4 keys, for deactivation or total acti­vation of the 3 zones (A+B+C) or partial activation (A+B or B+C), with visual confirmation of the operation performed;
- up to 32 five-digit codes for deactivation, which depends on the zones enabled on the transmitter during the programming phase, and total or partial activation, usable on the control panel or keypads;
- activation override: the user can override to automatic alarm activation at a set time;
- via telephone calls on PSTN network or GSM (for mod. HSCU1GC only);
- on models with wired connections (mod. HSCU1GC and mod. HSCU1C) a switch can be connected to alarm activation/deactivation.
• Siren operation
- Indoor sirens: activated for 3 minutes in the event of “general”, “tampering” or “panic” alarms. Emission of an audible signal; 3 beeps on total or partial activation and 1 beep on deactivation. The volume can be adjusted through to level zero.
- Outdoor sirens: activated for 3 minutes in the event of “general”, “tamper­ing” or “panic” alarms. To avoid disturbance, if the system has been left acti­vated, the siren is activated after a pre-alarm interval of approx. 10 seconds, during which a series of beeps are emitted.
Emission of an audible signal on activation and deactivation (3 beeps on total or partial activation and 1 beep on deactivation). The volume can be adjusted through to level zero. The flashing light flashes during siren activation. In the case of an “outdoor” alarm, the siren remains silent, but a series of beeps are emitted for 3 minutes.
- Board with voice function for outdoor sirens: if the voice board is fitted, the sirens send out a warning message during the pre-alarm interval and in the event of an “outdoor” alarm. These messages must be recorded correct­ly to obtain the required dissuasion effect.
• Telephone calls
- On fixed PSTN line: up to 6 voice messages can be recorded for each specific event (see section 6.2.2), which are transmitted to up to 63 users, the numbers of whom are programmed accordingly.
- On GSM network: the same 6 messages envisaged for the fixed line can be transmitted via GSM. As well as the voice message, a corresponding text message can also be sent. A further 11 factory-set “technical” text messages (see section 6.2.3) are transmitted on the occurrence of specific events.
- Calls to alarm receiving centres: the control units can communicate with the digital protocol Contact ID and CESA 200 Baud, for contact with alarm receiving centres. For specific settings, request the relative instructions from the Nice service centre.
- Remote assistance calls: the control units can be set up to enable the professional installer to make a remote connection for checks and set-up operations on the system (see section 6.2.7 - 9.2.8).
• Domotic functions
- Programmable clock: the control unit is fitted with a programmable clock for automatic activation.
- Relay outputs (for models HSCU1GC and HSCU1C only): two relays are available for the control of electrical appliances, which can be activated via the clock by a telephone call or via specific control unit functions (see chapter
9.2.7 - 9.2.9).
- Outputs via radio: 16 commands via radio are available for actuator mod­els HSTT2L and HSTT2N, which can be activated via a telephone call or directly via transmitters, keypads or detectors (see chapter 9.2.9).
9
q
p
o
m
l
i
h
g
f
e
d
c
b
a
n
m
l
i
h
f
d
c
b
a
6A
Models HSCU1G and HSCU1
6B
Models HSCU1GC and HSCU1C
4.1 - Set-up of system components for configuration
All system devices communicate via radio therefore the system should be con­figured on a table before final installation of all devices. The following operations should be carried out for control units that require electrical connections:
1) configuration of radio devices on a table;
2) final installation of each device;
3) electrical connections.
To avoid errors, operation and reception problems proceed as follows:
The perfect radio coverage of the devices can be checked using this pro­cedure before installation.
a) Open the packaging and lay out all the products on a table; b) Insert the “voice guide” memory board supplied in the control panel; on the
GSM version also insert the “SIM” card (see installation paragraph);
c) Power up the control unit and program it in “device acquisition” mode; d) Put the batteries in the devices which will then be acquired one by one by
the control unit;
d) Test operation of the devices; e) Place the control unit in the envisaged point (without fixing); f) Place all the other devices in the envisaged points (without fixing); g) Check that each device has sufficient coverage for radio communication
(see paragraph “Testing the control unit”). On the GSM versions check that the signal strength and coverage are suf­ficient;
h) Install all devices; i) If necessary, configure the control unit with the advanced and detailed func-
tions.
The next paragraphs describe the control panel installation phases (for all mod­els) and electrical connections of versions that envisage wiring.
4.2 - Preliminary installation checks and product applica-
tion limits
Before proceeding with installation, check the condition of the product, suit­ability of the selected model and suitability of the intended installation environ­ment.
• Check that all use conditions are within the “product application limits” and as
stated in the “Product technical specifications”.
• Check that the intended installation area is suitable for the overall size of the
product.
• Check that the fixing surfaces are sufficiently solid and that the areas are pro-
tected against the risk of impact.
• The product can only be used with products part of the Nice Home Security
system.
4.3 - Control unit description
All control unit models have a system memory board with voice guide (“l
fig. 6A - 6B). The voice of this guide is in the language of this manual; versions in a different language are available on request.
This memory board is supplied with this manual and must be inserted in the con­trol unit before starting installation and with the power off (see paragraph 4.4.2). This board records all system parameters (excluding voice messages recorded by the installer or user) of every programming operation and can be transferred from one control unit to another.
Some control unit models (models HSCU1GC and HSCU1G) are equipped with a GSM telephone dialler. The SIM card must be inserted before starting installation and with the power off (see paragraph 4.4.2). The SIM card can be of any operator and subject to any type of contract (only the “voice” and text messaging services are used) but it must be configured with the PIN code = “1234” or have the function “access without PIN” active: this operation can be carried out by inserting the SIM card into any GSM telephone.
Control unit description:
Fig. 6A mod. HSCU1G and HSCU1 - Fig. 6B mod. HSCU1GC and HSCU1C
a - Display b - Keypad c - Microphone d - Socket for PSTN telephone line e - Hole for cable routing f - PC connection socket g - Terminal board for electrical connections (models HSCU1G and HSCU1GC) h - Internal siren i - Loudspeaker l - System memory board with voice guide m - GSM SIM (models HSCU1G and HSCU1GC)
n - Battery pack (models HSCU1G and HSCU1) o - Buffer battery (models HSCU1GC and HSCU1C) p - Electric mains power terminal (models HSCU1GC and HSCU1C) q - Power supply unit (models HSCU1GC and HSCU1C)
INSTALLATION: the control panel and accessories
4
10
4.4 - INSTALLATION: Control unit
(models HSCU1GC - HSCU1C and HSCU1G - HSCU1)
4.4.1 - Warnings
Before proceeding with installation carefully read paragraphs 4.1 - 4.2 - 4.3.
4.4.2 - INSTALLATION
01. Remove the protection grille (fig. 7-A) and the cover (fig. 7-B) to open the
housing;
02. Unhook the side hook so that the body of the control unit can be rotated
(fig. 8);
03. Insert the memory board supplied; ensure that it is correctly inserted in the
internal connector guides (fig. 9).
On control unit models HSCU1GC and HSCU1G (with GSM) also insert the SIM card (fig. 10).
04. Before fixing the housing, the “anti-lever” system can be activated if
required on the rear tampering detector (fig. 11):
a) remove part “a” as shown and set aside b) remove part “b” as shown and throw it away;
05. For models HSCU1GC
and HSCU1C: make a hole for the cables (fig.
12) and route the electric power cables through the hole (fig. 13);
06. Refit the control body unit in its seat (fig. 14);
07. Mark the 3 fixing points shown in fig. 15 on the wall. If the “anti-lever” sys-
tem has been activated also mark the 4th point for part “a” (fig. 15);
08. Drill holes in the wall at the 3 fixing points and insert the screws and plugs
supplied (fig. 16). If the “anti-lever” system has been activated also drill a hole at the 4th point and insert the plug and part “a”, previously set aside (fig. 16);
09. Fix the control unit to the wall using the screws supplied (fig. 17);
10. Electrical connections:
For models HSCU1GC
and HSCU1C:
make the electrical connections and insert the buffer battery as described in chapter 5.
• For models HSCU1G and HSCU1:
connect the battery pack as shown in fig. 18;
11. Close the housing (fig. 19).
12. Now proceed with the installation of the various devices as envisaged (see
paragraph 4.5) and program the control unit (see chapter 6).
8
9 10
x 4
11
7A 7B
12
b
a
11 12
13
CRACK
CRACK
CRACK
14
x 3
x 1
a
15
18
only for models
HSCU1G and HSCU1
x 4
19
x 3
a
16
x 3
17
13
ACCESSORIES
14
4.5 - Door and window opening detector
(model HSDID11)
4.5.1 - SPECIAL WARNINGS
To avoid intentional damage, install the product in a position that is difficult to reach.
4.5.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDID11 is a detector for doors and windows that signals opening as the magnet is separated from the sensor body. Suitable for use in protected indoor and outdoor areas. It detects opening of a door or window and signals it via radio to the associated control unit. Any other use is to be considered improper and prohibited! Nice declines all liability for damage resulting from improper use of the product and any use other than as specified in this manual.
4.5.3 - OPERATION
HSDID11 is a detector suitable to protect doors and windows in case of opening (sep­aration of the magnet from the sensor).
To increase protection it is fitted with a second input for NC type contacts which can be used to connect another sensor, also pulse type (detector for rolling shutters).
As well as the NC input there is an input for NO contacts which can be used to connect NO type sensors such as the flooding detector HSDIW01.
The alarm can be single or differentiated for the different detections of the magnetic sensor and NC + NO input.
Communication is completely via radio with dual band technology; battery operated – standard 9 V.
Equipped with LED indicator visible from the outside.
Types of alarm signals
:
– Intruder alarm: alarm signal following opening of door or window. – Second alarm: the HSDID11 can be programmed to transmit 2 different alarms
(transmission of 2 different codes): one for the magnetic contact and one for the input of the NC or NO contacts.
– Supervision: transmission of a signal every 40 minutes to indicate that the system is
running.
– Anti-opening protection: the opening of the battery compartment and/or separation
of the device from the surface on which it is fixed triggers the “tampering” alarm. To avoid this set the control unit to “TEST” mode before opening the sensor.
– External LED:
• when the LED illuminates for 1 second it indicates that there has been an alarm signal;
• after the alarm signal, if the LED flashes quickly 4 times (timed with 4 acoustic
beeps) it means that the battery is almost discharged. Replace the battery only when the control unit indicates that the detector has a dis­charged battery. To replace the battery see the instruction manual of the HSDID11.
4.5.4 - INSTALLATION
For installation operations see the instruction manual of the HSDID11.
4.5.5 - PROGRAMMING OF DIP SWITCHES
Caution! – To program the “dip-switches” remove the battery from the device;
remove the battery also to make any changes and then reprogram. See fig. 20:
1 OFF = alarm signal only when open. 1 ON = alarm signal when open and closed (alarm end).
2 OFF = non-differentiated alarm
signal: single code for both alarms.
2 ON = differentiated
alarm signal: 2 different codes, one for the detector alarm
and one for the alarm of the NC or NO input.
3 OFF = immediate
alarm signal on opening of NC input or closure of NO input.
3 ON = alarm signal after 6 pulses on NC input.
4 OFF = intruder sensor disabled (for areas subject to vibrations). 4 ON = intruder sensor enabled (alarm signal in common with opening signal).
5* OFF = Anti-removal/tamper protection enabled. 5* ON = Anti-removal/tamper protection disabled (to be used when fixed on irregular
or unstable surfaces)
6* = Not used.
(*) available from April 2010.
4.5.6 - CONNECTION OF EXTERNAL DEVICES
To connect external devices using wires to the NC or NO contact see fig. 21.
With dip-switch 3 set to “ON” the input is suitable for controlling rolling shutter detectors or inertia sensors where the alarm is sig­nalled after 6 pulses in 30 sec­onds. The NC input is automati­cally activated by closing the con­tact for at least 10 seconds after inserting the battery.
To memorise the detector in the control unit see chapter 6.
If the NC input on the terminal board is used and a differentiated alarm is required, the following memorisation steps must be carried out:
• at first leave the dip switch N° 2 = OFF (non-differentiated alarm)
• set the control unit for memorisation of the first code (magnetic detector); then insert the battery to carry out memorisation
• set the control unit for memorisation of the second code (NC input); then move dip switch N° 2 = ON when requested to “insert battery in detector”.
NO
NC
21
20
dip-switch 1 dip-switch 2
dip-switch 3 dip-switch 5
dip-switch 4
ACCESSORIES
15
4.6 - Infrared detector with volumetric lens
(model HSDIM11)
4.6.1 - SPECIAL WARNINGS
To avoid intentional damage, install the product in a position that is difficult to reach
• Do not install the product near possible hot or cold air turbulences or where there are animals (hot blooded).
• If pets enter the environment controlled by the sensor the sensor must be adequate­ly positioned and aimed so that the sensitivity area is 50-70 cm above the ground as shown in fig. 23; if necessary, reduce sensitivity of the sensor.
4.6.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDIM11 is an infrared detector with volumetric lens for indoor use; it detects the movement of an intruder in the protected area and transmits it via radio to the control unit to which it is associated. Any other use is to be considered improper and prohibit­ed! Nice declines all liability for damage resulting from improper use of the product and any use other than that specified in this manual.
4.6.3 - OPERATION
HSDIM11 is an intruder detector that signals the movement of people in the protected area. To increase protection it is fitted with a second input for NC type contact which can be used to connect another sensor, also pulse type (detector for rolling shutters); the alarm can be single or differentiated for the two different detections. It contains anti-tampering and anti-break-in detectors. Communication is completely via radio with dual band technology; battery operated – standard 9 V. Equipped with LED indicator visible from the outside.
Types of alarm signal
:
– Intruder alarm: alarm signal caused by the detection of movement in the protected
area. In order not to waste the batteries the detector does not send out any other signal after the first alarm signal if there is no further movement for at least 2 minutes (except when the battery compartment is open).
– Second alarm: the HSDIM11 can be programmed to transmit 2 different alarms
(transmission of 2 different codes): one for movement detection and one for the NC contact.
– Supervision: transmission of a signal every 40 minutes to indicate that the system is
running.
– Anti-opening protection: the opening of the battery compartment and/or separa-
tion of the device from the surface on which it is fixed triggers the “tampering” alarm. To avoid this set the control unit to “TEST” mode before opening the sensor.
– External LED:
• when the LED comes on for 1 second it indicates that there has been an alarm signal;
• after the alarm signal, if the LED flashes quickly 4 times it means that the battery is almost discharged.
Replace the battery only when the control unit indicates that the detector has a dis­charged battery. To replace the battery see the instruction manual of the HSDIM11.
4.6.4 - INSTALLATION
For installation operations see the instruction manual of the HSDIM11.
4.6.5 - PROGRAMMING OF DIP SWITCHES Caution! – To program the “dip-switches” remove the battery from the device;
remove the battery also to make any changes and then reprogram.
Dip-switch functions (fig. 24):
1 OFF = sensitivity: for range of about 5 m. 1 ON = sensitivity: for range of about 10 m.
2 OFF = non-differentiated alarm signal: transmission of single code for both alarms. 2 ON = differentiated alarm signal: transmission of 2 different codes, one for the
detector alarm and one for the alarm of the NC input.
3 OFF = immediate alarm signal of opening of NC input. 3 ON = alarm signal after 6 pulses on NC input.
4 OFF = alarm signal when movement of the intruder is first detected. 4 ON = alarm signal when movement of the intruder has been detected twice.
5* OFF = Anti-removal/tamper protection enabled. 5* ON = Anti-removal/tamper protection disabled (to be used when fixed on irregular
or unstable surfaces)
6* = Not used.
(*) available from April 2010.
4.6.6 - CONNECTION OF EXTERNAL DEVICES
To connect external sensors using wires to the NC contacts see fig. 25. With dip­switch 3 set to “ON” the input is suitable to control rolling shutter detectors or inertia sensors where the alarm is signalled after 6 pulses in 30 seconds.
The NC input is automatically activated by closing the contact for about 10 seconds after inserting the battery.
To memorise the detector in the control unit see chapter 6.2.4.
If the NC input on the terminal board is used and a differentiated alarm is required, the following memorisation steps must be carried out:
• at first leave the dip switch N° 2 = OFF (non-differentiated alarm)
• set the control unit for the memorisation of the first code (infrared detector); then insert the battery to carry out memorisation
• set the control unit for the memorisation of the second code (NC input); then move the dip switch N° 2 = ON when requested to “insert battery in detector”.
24
dip-switch 1 dip-switch 2
dip-switch 3 dip-switch 4 dip-switch 5
5 m
10 m
30°
30°
22
123 456 8 9107
2,5
1,5 1
123 456 8 9107
0,5
2
2,5
1,5 1 0,5
2
23
NC
25
Horizontal view Vertical view
12 m
10 m
90°
30°
ACCESSORIES
16
4.7 - Infrared detector with vertical curtain lens (model HSDIM12)
4.7.1 - SPECIAL WARNINGS
• To avoid intentional damage, install the product in a position that is diffi-
cult to reach.
• Do not install the product near possible hot or cold air turbulences or
where there are animals (hot blooded); if necessary reduce the sensitivity of the sensor.
4.7.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDIM12 is an infrared detector with vertical curtain lens for use in protected indoor and outdoor areas; designed to protect access areas (doors/windows). It detects the movement of an intruder in the protected area and transmits it via radio to the associated control unit. Any other use is to be considered improper and prohibited! Nice declines all liability for damage resulting from improper use of the product and any use other than as specified in this manual.
4.7.3 - OPERATION
HSDTIM12 is a perimeter protection detector for doors and windows; thanks to its cur­tain lens it signals the movement of persons present only within the close range in front of the sensor. To increase protection it is fitted with a second input for NC type contact which can be used to connect another sensor, also pulse type (detector for rolling shutters); the alarm can be single or differentiated for the two different detections. It contains anti-tampering and anti-break-in detectors. Communication is completely via radio with dual band technology; battery operated – standard 9V. Equipped with LED indicator visible from the outside.
Types of alarm signal
:
– Intruder alarm: alarm signal caused by the detection of movement in the protected
area. In order not to waste the batteries the detector does not send out any other sig­nal after the first alarm signal if there is no further movement for at least 3 minutes (except when the battery compartment is open).
– Second alarm: the HSDIM12 can be programmed to transmit 2 different alarms
(transmission of 2 different codes): one for movement detection and one for the NC contact.
– Supervision: transmission of a signal every 40 minutes to indicate that the system is
running.
– Anti-opening protection: the opening of the battery compartment and/or separa-
tion of the device from the surface on which it is fixed triggers the “tampering” alarm. To avoid this set the control unit to “TEST” mode before opening the sensor.
– External LED:
• when the LED comes on for 1 second it indicates that there has been an alarm signal;
• after the alarm signal, if the LED flashes quickly 4 times it means that the battery is almost discharged
Replace the battery only when the control unit indicates that the detector has a dis­charged battery. To replace the battery see the instruction manual of the HSDIM12.
4.7.4 - INSTALLATION
For installation operations see the instruction manual of the HSDTIM12.
m
6
1
0
2
3
4
5
0,500,5
1
0
2
3
4
5
6
m
22,5° 22,5°
Vista in larghezza
Vertical view
4.7.5 - PROGRAMMING OF DIP SWITCHES IMPORTANT! – The “dip-switches” must be programmed before powering the de -
vice. Also disconnect the battery to make any modifications and then reprogram.
See fig. 26:
1 OFF = sensitivity: for range of about 3 m. 1 ON = sensitivity: for range of about 6 m.
2 OFF = non-differentiated alarm signal: transmission of single code for both
alarms.
2 ON = differentiated
alarm signal: transmission of 2 different codes, one for the
detector alarm and one for the alarm of the NC input.
3 OFF = immediate
alarm signal of opening of NC input.
3 ON = alarm signal after 6 pulses on NC input. 4 OFF = input in use, NC contact connection necessary.
4 ON = input not in use (factory setting); the input is closed by the dip-switch. 5* OFF = Anti-removal/tamper protection enabled.
5* ON = Anti-removal/tamper protection disabled (to be used when fixed on irregular
or unstable surfaces)
6* = Not used.
(*) available from April 2010.
4.7.6 - CONNECTION OF EXTERNAL DEVICES
To connect external sensors using wires to the NC contacts see fig. 25. With dip-switch 3 set to “ON” the input is suitable to control rolling shutter detectors or inertia sensors where the alarm is signalled after 6 pulses in 30 seconds.
To memorise the detector in the control unit see chapter 6.2.4.
If the NC input on the terminal board is used and a differentiated alarm is required the following memorisation steps must be carried out:
• at first leave the dip switch N° 2 = OFF (non-differentiated alarm)
• set the control unit for the memorisation of the first code (infrared detector); then insert the battery to carry out memorisation
• set the control unit for memorisation of the second code (NC input); then move the dip switch N° 2 = ON when requested to “insert battery in detector”.
3 m
6 m
26
dip-switch 1 dip-switch 2
dip-switch 3 dip-switch 4 dip-switch 5
ACCESSORIES
17
4.9 - Fine combustion powder detector (model HSDIS01)
4.9.1 - SPECIAL WARNINGS
Caution! – The detector must not be considered a total protection but simply a sup­port in the protection against combustion risks. The device is not a fire detector and does not comply with any regulations on fire detection.
• The alarm signal emitted by the detector may not be heard by people with hearing problems or under the effect of alcohol or drugs.
• Install the product in a position that is difficult to reach to avoid any damage.
• Do not modify sensitivity of the detector.
• The detector must not be painted or varnished.
• Battery lifetime is reduced in the event of frequent alarm signals.
• The detector may not function correctly if the batteries are discharged.
• To clean the surface of the detector use a soft, slightly damp cloth; do not use products that contain alcohol, benzene, diluents or similar. Do not dust with feath­er dusters.
• The device must be replaced after 10 years of use; within 2-3 years if installed in particularly dusty areas.
4.9.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDIS01 is a fine combustion powder detector (mist or smoke effect); suitable for indoor use. Any other use is to be considered improper and prohibited! Nice declines all liability for damage resulting from improper use of the product and any use other than as specified in this manual.
4.9.3 - OPERATION
HSDIS01 is a fine combustion powder detector (mist or smoke effect) designed for residential applications. A photodiode detects opacity of the air and signals the alarm directly on site (by means of a buzzer) and also via radio to the control unit. The detection technology used is of the photo-optical type and does not emit any type of harmful radiations. It is suitable to control an area of up to 6 x 6 m; it should be installed on the ceiling at the centre of the area. Smaller rooms that are not square, such as corridors, require the use of more than one detector. Communication is completely via radio with dual band technology; battery operated
- 9 V standard.
Equipped with LED indicator visible from the outside and buzzer for audible signals.
Types of alarm signal
: – Normal operation (self-diagnosis): LED flashes briefly every 45 seconds; – Alarm status: the concentration of combustion powders in the environment gen-
erates transmission of the alarm signal via radio, continuous flashing of the exter­nal LED and continuous sounding of the buzzer. The alarm status ends when the situation ends;
– Presence of heavy powders inside the sensor: short acoustic tone every 45
seconds and flashing of the external LED not synchronised with the acoustic tone. This alarm status ends once the powder has been removed (this operation must be carried out by the technical assistance service);
– Battery almost discharged: short acoustic tone every 45 seconds and flashing
of the external LED synchronised with the acoustic tone. Replace the battery only when the control unit indicates that the detector has a discharged battery. To replace the battery see the instruction manual of the HSDIS01. The battery can be replaced by opening the sensor; this does not generate alarms (the detector does not have a tampering sensor)
– Supervision: transmission of a signal every 40 minutes to indicate that the sys-
tem is running.
4.9.4 - INSTALLATION
For installation operations see the instruction manual of the HSDIS01.
4.9.5 - PROGRAMMING
HSDIS01 does not require any adjustments or programming.
To memorise the detector in the control unit see chapter 6.2.4. Memorisation is usually carried out in the zone of the technical alarms.
4.9.6 - TEST
The detector is equipped with a test button to verify efficient operation of the detector. Press the button for about 1 second to test the sensor; if it is in good working order the LED should flash, the buzzer should emit acoustic tones and the alarm signal should be transmitted. To guarantee adequate safety levels, the test should be carried out at least once a month.
4.8 -Volumetric detector of glass breakage (model HSDID01)
4.8.1 - SPECIAL WARNINGS
• To ensure optimal detection, the device must be installed in rooms with an area of 20 to 30 square metres, at a distance of 3 to 6 m from the glass to be protected and at a height of approx. 2 m (fig. 27).
Installation is not recommended
: in areas with dimensions of less than 3 x 3 m, in excessively humid environments (bathrooms or kitchens) or in garages with large metal doors. These situations may generate improper alarms.
• Battery lifetime is reduced if the detector is placed in very noisy areas due to the continuous signalling of noise.
4.8.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDID01 is a detector of glass breakage; suitable for indoor use. Any other use is to be considered improper and prohibited! Nice declines all liability for damage result­ing from improper use of the product and any use other than as specified in this manual.
4.8.3 - OPERATION
HSDID01 is a sensor suitable to detect glass breakage; suitable for normal glass, double glazing or security glazing. The detector is equipped with a microphone cal­ibrated to recognise the sound of breaking glass. It must be used with a great deal of attention because it may also detect a china cup that falls on the floor; the sensor should only be activated when there is no risk of other sounds that may trigger the alarm.
Also appliances able to generate sudden pressure surges in rooms (air conditioners, fans) may generate improper alarms.
Sound-absorbing materials (such as curtains and carpets) may reduce sensitivity of the device.
The device is optimised with factory-setting and may not be modified. It contains an anti-tampering detector. Communication is completely via radio with dual band technology; battery operated
- 9 V standard
Equipped with LED indicator visible from the outside.
Types of alarm signal
:
– Noise signal (test): by producing a sudden noise in front of the detector (clap-
ping hands or knocking two metal objects together) the led should flash briefly twice. These noises do not trigger the alarm. Caution! – If the LED does not flash after the noise test the battery may be discharged or the device may be faulty.
– Alarm status: the breakage of glass (an old bottle can be broken for testing) gen-
erates the transmission via radio of the alarm signal and makes the LED switch on for 4 seconds. The LED flashes for about one minute after the alarm;
– Anti-opening protection: The opening of the casing triggers the “tampering”
alarm signal. To avoid this problem, set the control unit to “TEST” mode before opening the sensor.
– Battery discharged: The low battery signal is transmitted to the control unit a few
days in advance. Replace the battery only when the control unit indicates that the detector has a discharged battery. To replace the battery see the instruction man­ual of the HSDID01.
– Supervision: transmission of a signal every 40 minutes to indicate that the sys-
tem is running.
4.8.4 - INSTALLATION
For installation operations see the instruction manual of the HSDID01.
4.8.5 - PROGRAMMING
HSDID01 does not require any adjustments or programming.
To memorise the detector in the control unit see chapter 6.2.4.
~ 2 m
3 ÷ 6 m
20 ÷ 30 m
2
27
ACCESSORIES
18
4.10 - Flooding detector
(model HSDIW01)
4.10.1 - SPECIAL WARNINGS
• To obtain optimal detection, the device must be installed vertically on the wall and flush with the ground surface.
• The sensor should be installed in a location most subject to the risk of water leaks, but if the floor is not level, it should be placed at the low­est point of the room.
• The sensor is connected to the NO input of one of the compatible detectors (for example HSDID11). The cable length must not exceed 10 m. Multiple sensors may be connected in parallel on the same input of the detector.
4.10.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSDIW01 is a flooding detector destined for use in alarm systems for indoor applica­tion. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as specified in this manual.
4.10.3 - OPERATION
The sensor comprises 2 electric contacts placed at approx. 1 mm from the floor. In the event of a flood, when the sensor comes into contact with liquid, the event is immedi­ately read by the detector connected to HSDIW01 by a cable; this then transmits the emergency signal to the control unit via radio.
Types of alarm signal
:
HSDIW01 does not emit any signal.
4.10.4 - INSTALLATION
For installation procedures, refer to the HSDIW01 instruction manual.
4.10.5 - PROGRAMMING
HSDID01 does not require any adjustments or programming. Programming of a differ­entiated alarm is recommended on the detector connected to the sensor; in this way the flooding alarm can be distinguished from other types of alarm.
4.11 - 4-channel alarm transmitter (model HSTX4)
4.11.1 - PRODUCT DESCRIPTION AND INTENDED USE
HSKPS is a bidirectional keypad with 64 bit variable code (rolling code); it enables the activation and deactivation of alarm control units, and receives operation confirmation signals from the latter; otherwise it can be used to control other receivers in the system. Designed for indoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as speci­fied in this manual.
4.11.2 - OPERATION
HSTX4 is fitted with 4 keys; each one is normally assigned with a specific function:
x = Key : total deactivation
y = Key : total activation
z = Key : partial activation (zones A+B)
w = Key : command key (panic, illness or burglar alarm or receiver control)
The assigned function on keys [ ] and [ ] can be changed, for example key [ ] can
be used as a command key or key [ ] may be used as a second partial activation key
(zones B+C); to change the assigned function refer to the paragraph “programming”.
4.11.3 - PROGRAMMING
The transmitter is programmed via the control unit and on the receivers to be asso­ciated.
Further information on the memorisation procedure can be found in the instructions of the relative products.
• Programming the transmitter on the control unit:
- Set the control unit to remote control programming mode and perform the preliminary phases required (see chapter 6.2.4.1);
- When the control panel menu displays the request: on the transmitter, press and hold
the keys and simultaneously for 10 seconds; the control panel then emits a
beep to confirm programming. This programming procedure memorises the key for
total arming , key for disarming and for partial arming.
Key is not memorised and is left free for alarm control (panic or robbery) or to con-
trol receivers.
• Programming the key [ ] on the control panel to send “panic” or “robbery” alarms:
- Set the control panel to programming mode in the zone “Panic” or “Robbery2 (see chapter 6.2.4.5) according to the type of alarm to be activated.
- When the control panel menu displays the request: on the transmitter, press and hold
the key for 10 seconds; the control panel then emits a beep to confirm programming.
• Programming the key (or ) to control a receiver:
- Set up the receiver for radio code memorisation (see specific instructions); when required, press and hold key for 10 seconds.
If required, the factory set function of keys and can be changed.
- To change the function of key
from partial arming (zones A+B) to control key:
press and hold keys and for 10 seconds; the led emits 3 short orange flashes to
confirm conversion from the partial activation function to the command key function.
- To change the function of key
from command key to partial arming (zones B+C)
press and hold keys and for 10 seconds; the led emits 2 short orange flashes to
confirm conversion from the command key function to the partial arming function. The
functions can be changed in the other direction simply by repeating the operation. On
completion, the led emits 2 short flashes if the key is assigned for partial activation or 3
short flashes if it is assigned as a command key.
The zones partially armed by means of keys (partial A+B) and (partial B+C) are not
modifiable and depend on the fact that these zones are included during memorisation of
the remote control (keys OFF and ON). The keys for partial activation do not require a spe-
cific memorisation procedure as this is performed at the same time as that of keys and
; while keys and need to be memorised specifically if used to control alarms
(panic or robbery) or to control receivers.
4.11.4 - SIGNALS
The transmitter is bidirectional; after sending the activation or deactivation commands, partial or total (phase in which the orange led is illuminated) it remains on standby for response by the control unit (phase in which the orange led flashes), after which the result is displayed as follows:
Green led lit for 2 seconds: OFF, system deactivated Red led lit for 2 seconds: ON, system activated (total or partial) Led off: response not received
The command keys do not have a response standby setting; after sending the com­mand the led turns off immediately.
When the battery charge is low, the transmitter range is reduced significantly. When a key is pressed, if led L1 illuminates and then immediately fades and turns off, this means that the battery is completely discharged and must be replaced immediately.
Otherwise if led L1 illuminates briefly and then turns off, this means that the battery is only partially discharged; in this case press and hold the key for at least half a second to enable the transmitter to attempt delivery of the command and wait for the response. In any event, if the battery charge is too low to complete an operation, the led fades and the transmitter turns off.
When the battery is discharged, the battery must be replaced with the same version to restore normal transmitter operation.
To replace the battery, refer to the HSTX4 instruction manual.
x
z
y
w
L1
4.12 - 8-channel radio transmitter (model HSTX8)
4.12.1 - PRODUCT DESCRIPTION AND INTENDED USE
HSTX8, is a bidirectional radio transmitter with variable code (rolling-code) and 8 chan­nels; 4 for alarm systems and 4 for direct control of receivers and automations for doors and gates. Designed for indoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as specified in this manual.
4.12.2 - OPERATION
HSTX8 is a radio transmitter with 8 channels divided into two groups of 4 channels; for the first 4 keys, encoding is compatible with the “Nice Home Security” systems, while the other 4 keys have “O-Code” encoding, Nice-One compatible, used for the control of automations of doors, gates and similar products.
For the first 4 keys, the functions and operation are identical to those of the transmitter HSTX4; for details refer to the relative instructions.
The other 4 keys (1-2-3-4) use a transmission technol­ogy called “O-Code”, with variable code (rolling-code), which significantly improves
the command transmission speed and enables a series of evolved functions typical of the system Nice­Opera.
For further information on all functions of the system NiceOpera and operative interdependency of the vari­ous system devices, refer to the general manual “NiceOpera System Book”, also available on the web site www.niceforyou.com
Further information can also be found in the specific instruction manual of HSTX8.
x
z
y
w
L1
19
4.13 - Control keypad
(model HSKPS)
4.13.1 - SPECIAL WARNINGS
Install the product in an easily accessible location (for example close to the main entrance).
4.13.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSKPS is a bidirectional dual band keypad that enables the activation and deactivation of alarm control units, and receives operation confirmation signals from the control unit; otherwise it can be used to control other receivers in the system. Designed for indoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as speci­fied in this manual.
4.13.3 - OPERATION
Enables partial or total activation or deactivation of the control unit by means of a 5-dig­it code. Maximum transmission security is guaranteed thanks to encrypting using a Rolling Code system. The keypad can transmit other commands via radio to the control unit or to specific receivers for automations. An internal buzzer confirms manoeuvres and emits audible signals when new events occur. A battery low signal is also incorporated. HSKPS can be wall-mounted or used in the tabletop version (with the special rubber support mod. HSKCT - optional accessory).
Description of leds and keys
There are 8 indicator leds, 10 numerical keys and 10 function keys (fig. 28):
1 = A, B, C zone leds: lit when the zone is active
2 = Led : transmission; lit when a radio signal is transmitted
3 = Led : warning – new event; lit when the control unit is deactivated, to signal a
new event
4 = Led : warning – door open; lit when the control unit is activated and a door or
window has been left open
5 = Led : warning – battery charge low; lit when the control unit is activated or
deactivated to indicate that the battery charge is low and batteries need to be replaced
6 = Led : lit during standby for confirmation of a control unit command
7 = Keys , and : keys for direct radio commands (no code entry required)
to activate specific functions or to control radio receivers, e.g. HSTT2L (see: “Use as general transmitter”)
8 = Key : reset key, used to delete a code entered incorrectly
9 = Keys , and : used to select the zones to be activated or deactivated
(A, B, and C)
10 = Key : used to send an activation command to the control unit
11 = Key : used to send a deactivation command to the control unit
12 = Key : used to send a query command to the control unit
13 = Keys “0 - 9”: numerical keys used to enter the code to send to the control unit
or receivers associated with HSKPS.
Functions available and relative signals
• Control unit activation/deactivation:
- Total activation: enter the personal 5-digit code and after entry of the fifth digit, leds “A - B - C” illuminate, after which press the red key . Entry is confirmed by the emission of 3 beeps and leds A - B - C remain lit for 30 seconds.
- Partial activation: enter the personal 5-digit code and after entry of the fifth digit,
leds (A - B - C) illuminate. Press keys , or of the zones not to be activated;
the relative leds turn off. Now press the red key ;
- Deactivation: enter the personal 5-digit code and after entry of the fifth digit, leds “A - B - C” illuminate, after which press the green key . Deactivation is confirmed by the emission of 1 beep and leds A - B - C remain off. Note – Deactivation is always total, even if keys , or are pressed to turn off specific zone leds.
- Deactivation under force (anti-duress): If one or more anti-duress codes have been programmed on the control unit, as an alternative to entry of the personal 5-dig­it code, this specific 5-digit code can be entered, which, as well as deactivating the control unit also makes telephone calls to request assistance as envisaged for this function (see chapter 6.2.4.2).
• Code entry errors: if an incorrect code is entered, press the key to reset and
enter the correct version.
Incorrect code: if an incorrect code is used (code not memorised) led [ ] flashes 8
times, and during this interval led [ ] remains lit. After 8 attempts with an incorrect code, all leds start flashing, and the control unit remains blocked for 30 seconds.
• Control unit status check: press the key to query the control unit; after a brief
interval the leds (A, B, C) illuminate according to the zones activated; if no led turns on, this means that the control unit is deactivated.
• Use as general transmitter: as well as the normal control unit activation and deacti-
vation functions, the keypad can be used as a transmitter for direct control of specif­ic functions or to activate receivers.
- is a direct command key; if memorised on the receivers (e.g. HSTT2L) it trans-
mits an ON and OFF command (toggle) each time it is pressed.
- is a direct command key; if memorised on the receivers (e.g. HSTT2L) it trans-
mits a command (pulse) each time it is pressed.
- is a direct command key; it is normally memorised on the control unit as a “pan-
ic” or “burglar” alarm activation key, but can also be memorised on the receivers (e.g.
HSTT2L) to transmit a command (pulse) each time it is pressed. Caution! – Trans-
mission occurs after the key has been pressed for 2 seconds.
- By pressing the numerical keys, for example 25, followed by keys and acti-
vation and deactivation commands can be sent respectively to the correspon-
ding receiver memorised with the code 25 (e.g. HSTT2L).
4.13.4 - INSTALLATION
For installation procedures, refer to the relative instruction manual.
4.13.5 - PROGRAMMING
The keypad is programmed via the control unit and on the receivers to be associated. Further information on the memorisation procedure can be found in the instructions of
the relative products.
Programming the keypad on the control unit (to use the 5-digit code for activa-
tion/deactivation):
- insert the batteries (remove the separation tab) on the keypad; a beep is emitted and all leds flash for 60 seconds.
- Within this interval, the control unit must be activated and then deactivated (with any other device enabled); on deactivation, 6 beeps are emitted to confirm memorisation of the keypad on the control unit. This operation must be performed each time the keypad batteries are changed.
Programming the key to send “panic” or “burglar” alarms:
- set the control unit to programming mode in the zone “Panic” or “Burglar” (see chapter 6.2.4.5) according to the type of alarm to be activated.
- when the control unit menu displays the request: on the keypad, press and hold the panic key for 10 seconds; the control unit then emits a beep to confirm program­ming. This programming also activates the tampering alarm via the keypad. If the key is not memorised, this alarm is not activated.
Programming keys and :
- to activate, set the receiver (or control unit) to memorise the radio code (see specif­ic instructions).
- when requested, press and hold the key for 10 seconds.
Programming the numerical keys to send commands - :
- set up the receiver for radio code memorisation (see specific instructions); when required, enter the numerical code on the keypad e.g. [25] then press and at the same time hold keys and for at least 1 second. Radio codes from 1 to 9999 can be used to control the corresponding number of receivers.
12
7
8
9
10111213
6435
28
ACCESSORIES
ACCESSORIES
20
4.14 - Indoor siren (modello HSSI)
4.14.1 - SPECIAL WARNINGS
Install the product in a location difficult to reach, to avoid inadvertent damage, possibly in a location where the sound produced can be propagated to the various other rooms. If necessary, fit additional sirens.
4.14.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSSI is a siren via radio with sound power of 114 dB; designed to signal intrusion and also to dissuade intruders. The unit is battery powered, can be wall-mounted and thanks to the compact dimensions can be positioned in concealed areas. Designed for indoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as speci­fied in this manual.
4.14.3 - OPERATION
HSSI signals intrusion with a powerful acoustic alarm. On each alarm command sent by the control unit, it emits an alarm signal lasting approx. 3 minutes; the alarm signal ter­minates when the control unit is deactivated. If the siren housing is opened (without first setting the associated control unit to TEST mode) an alarm signal is activated for approx. 3 minutes.
Acoustic signals
:
• 4 beeps = confirms activation of the control unit
• 1 beep = confirms deactivation of the control unit
• series of beeps for approx. 20 seconds on activation or deactivation of the control unit = batteries discharged
On activation of the battery discharged signal, the batteries must be replaced as soon as possible. Incorrect alarm signals may be generated when batteries are discharged.
4.14.4 - INSTALLATION
For installation procedures, refer to the relative instruction manual.
Volume adjustment: turn the potentiometer (fig. 26) to modify the volume of the beeps.
4.14.5 - PROGRAMMING
HSSI performs a self-programming function when activated/deactivated for the first time on the control unit; 6 beeps are emitted to confirm programming.
4.15 - Outdoor siren via radio
(model HSSO)
4.15.1 - SPECIAL WARNINGS
Install the product in a location difficult to reach, to avoid intentional damage, possibly in a location where the sound produced can be propagated efficiently in the required directions. If necessary, fit additional sirens.
4.15.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSSO is an outdoor siren via radio with sound power of 116 dB; designed to signal intrusion and also to dissuade intruders. Powered by a battery pack, the control via radio is bidirectional and dual band; suitable for outdoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as speci­fied in this manual.
4.15.3 - OPERATION
HSSO signals intrusion with a powerful acoustic alarm. On each alarm command send by the control panel, it emits an alarm signal lasting approx. 3 minutes; the alarm signal terminates when the control panel is disarmed. If the siren housing is opened (without first setting the associated control panel to TEST mode) an alarm signal is activated for approx. 3 minutes. The tamper alarm is also sent to the control panel. HSSO receives the signal on system status from the control panel and emits visual and audible signals (flashes) according to the specific status.
Signals
:
• 3 beeps and 3 flashes = confirms arming of the control panel
• 1 beep and 1 flash = confirms disarming of the control panel
• series of beeps with lamp lit, for approx. 12 seconds: delay before alarm
• continuous ring with lamp lit, for approx. 2 seconds: control panel in test mode; open­ing of the siren housing does not generate the tamper alarm.
• rapid series of beeps and flashes for approx. 30 seconds on arming and disarming of the control panel = batteries discharged On activation of the battery discharged signal, the batteries must be replaced as soon as possible. Incorrect alarm signals may be generated when batteries are discharged.
4.15.4 - INSTALLATION
For installation procedures, refer to the relative instruction manual. The following adjustments are possible before closing the housing:
– Volume adjustment: turn the potentiometer (fig. 30) to modify the volume of the beeps. – Deactivation of the intruder sensor for areas subject to vibrations. The intruder sensor can be deactivated by moving the jumper as shown in fig. 30. – Vocal message board: HSSO can be upgraded with the function for recording vocal messages for warnings and alarms, by adding the board model HSSOV (optional accessory).
4.15.5 - PROGRAMMING
To program and memorise HSSO on the control panel, proceed as follows:
• Set the control unit for the memorisation of the first code of an alarm sensor (groups A, B, or C); then insert the battery connectors to carry out memorisation. This operation enables the siren to transmit signals for the tamper alarm, low battery status and super­vision signal (every 40 minutes) to the control panel.
• Close the siren housing; a beep and short flash confirm perfect closure of the anti­tamper contacts.
• The siren is programmed on initial arming and disarming of the control panel. After this the siren confirms programming with 6 beeps and 6 flashes.
29
30
21
4.16 - External siren with wired connections (model HSSO)
4.16.1 - SPECIAL WARNINGS
Install the product in a location difficult to reach, to avoid intentional damage, possibly in a location where the sound produced can be propagated efficiently in the required directions. If necessary, fit additional sirens.
4.16.2 - PRODUCT DESCRIPTION AND INTENDED USE
HSSOC is an external wired siren with a sound power of 116 dB; designed to signal intrusion and also to dissuade intruders. Powered by the control panel, it envisages a backup battery (12 V 2,2 Ah) also for oper­ation in the event of a power failure; suitable for outdoor use. Any other use is to be considered improper and is strictly prohibited! Nice declines all liability for damage resulting from improper use of the product and other than as speci­fied in this manual.
4.16.3 - INSTALLATION
For installation procedures, refer to the relative instruction manual.
4.16.4 - PROGRAMMING
HSSOC does not require special programming. However, 2 settings are required before marking the electrical connections: a) TC block command: positive (+) or negative (-); for control panels HSCU1C and
HSCU1GC leave set to +. b) Alarm signal block: after 3 or 5 alarm cycles.
4.16.5 - ELECTRICAL CONNECTION TO CONTROL PANEL
To make the electrical connection to the control panel, refer also to chapter 5 in this instruction manual.
BATT +/-: electrical connection to backup battery. The back-up battery Pb-12V
2.2Ah (not supplied) is indispensable for siren operation.
P.SUPPLY +/-: electrical power supply connection from control panel ( P.SUPPLY - = GND; P.SUPPLY + = +SAA)
+ N: positive “on absence” which activates the alarm (if block is not present on T/C).
TAMPER: output (voltage-free contact) for tampering alarm, for tamper alarm input
connection on control panel (between GND and TMP A or B or C). Otherwise the tamper contact can be connected in series to + N.
T/C: block command, for connection to control panel armed/disarmed signal (+OFF).
For electrical connections, proceed in the following sequence:
01. connect the battery: the lamp starts flashing (it remains lit if the battery connection
is inverted).
02. connect the power supply to the control panel: P.SUPPLY + and -:
03. connect the activation signal +N: the lamp starts flashing immediately and 2
acoustic signals are emitted for approx. 2 seconds to confirm the siren standby status.
04. connect the tamper output
05. if present, connect the T/C alarm block command
4.16.6 - OPERATION
HSSOC signals intrusion with a powerful acoustic alarm. On each alarm trip from the control panel (+N), it emits an alarm signal lasting approx. 3 minutes; the alarm signal terminates when the control panel is deactivated.
If the “alarm block” connection is envisaged (T/C connected to +OFF of control panel) when the control panel is off, the siren is “blocked”; i.e. even if the alarm is activated (+N), no acoustic signal is activated, which normally occurs when the control panel is ON.
Also, for each control panel arming phase, the acoustic signals occur each time the alarm (+N) is armed, only until the programmed count is reached; the siren is then blocked when this number is exceeded.
The cycle count is reset when the control panel is switched off.
Luminous signals:
• 4 flashes = confirms arming of the control panel
• 1 flash = confirms disarming of the control panel
b
a
ACCESSORIES
22
A
B
31
33
32
5.1 - Warnings
The connection to the mains must be performed by skilled and quali­fied personnel in observance of standards governing electrical installa­tions.
• On the system, fit a 2-pole disconnect device with a gap between contacts of at least 3 mm, or use an electric cable equipped with a plug suited to a standard socket.
• Run any tests with battery power only (the battery must be fully charged.
5.2 - Connections on the control panel
(models HSCU1GC and HSCU1C only)
Caution! – Before opening the control panel housing, always disconnect
the mains power supply.
01. To connect the mains power cable, insert the ferrite cylinder as shown in
fig. 31 and position as shown in fig. 32;
Warnings:
- To facilitate insertion of the wires on the terminals, press the relative release button.
- The wires must be secured by tightening the screw on the terminal cover;
02. To make electrical connections to the terminal board, refer to Table 4;
03. To insert the backup battery (not supplied) refer to fig. 33;
04. On completion of connections, close the internal cover and only then acti-
vate the disconnect device and insert the plug in the socket.
5.3 - Connections on siren model HSSOC
To make the electrical connection between the siren and control panel, refer to Table 4 and see fig. 32
ELECTRICAL CONNECTIONS
5
SPK External loudspeaker output (8 Ω). Suitable for additional loudspeaker that reproduces the control panel messages; see fig. 34 + ALI Positive always present, for power supply of wired detectors; 12 Vdc maximum 500 mA; see fig. 35 + OFF Positive present when control panel is activated, for wired siren block command ; see fig. 36 GND (all) Negative for all connections + SIR Positive in alarm status, for additional sirens; 12 Vdc maximum 500 mA; see fig. 37 + SAA Positive (14 Vdc) for battery charger of wired sirens (not present in event of mains power failure; see fig. 36 + N Positive on absence , for alarm command on wired sirens. If more than one siren is connected, a diode must be inserted to avoid the
return signal; see fig. 36. Caution! – Do not use this output to power the sirens KEY Input for external key (closed = control panel disarmed); see fig. 38 A1-2 B1-2 C1-2 NC alarm inputs; see fig. 39 TMP A-B-C NC auto-protect (tamper) inputs; see fig. 39 NC1-COM1-NO1 R1 relay output (connect only to SELV extra low voltage safety circuits); see fig. 40 NC2-COM2-NO2 R2 relay output (connect only to SELV extra low voltage safety circuits); see fig. 40 PHONE Connection to fixed PSTN telephone line; see fig. 6 PC Connector for connection to PC (requires specific USB interface); see fig. 6
Notes:
• The alarm and tamper inputs must be NC and are enabled on initial closure. If closed inadvertently they indicate an alarm status. To clear the signal, enter and exit CONTROL PANEL TEST mode;
• The TMP inputs must be programmed on the same groups as the corresponding detectors.
TABLE 4 - DESCRIPTION OF ELECTRICAL CONNECTIONS
OUTPUT DESCRIPTION
23
A1 A2 TMPA GND
39
GND KEY
38
GND SAA
NC1
COM1 COM2
NO1
R1 R2
NC2
NO2
RELAY 12 Vcc
LN
LINE
40
SPK GND
+
-
34
ALI GND
SENSOR
+
-
35
SIR GND
+
-
37
+OFF
T/C
TAMPER
+SAA
GND
+N
+NALIMBATT
-+-+
TMPA
BATTERY
36
MENU 1
PHONE BOOK MESSAGES
EXTRAS SETTINGS DIGITAL PROTOCOLS PC REMOTE MANAGEMENT
Enables the memorisation, display and modification of telephone numbers for alarm calls. Enables recording of alarm messages and emergency assistance requests. In total, the system can store 6 vocal messa­ges, 6 SMS messages and 11 technical SMS messages. Enables configuration of system devices. Enables programming of special control panel functions. Enables configuration of digital communication protocols with alarm receiving centres. Enables configuration of the remote technical assistance options.
CONTROL PANEL PROGRAMMING
6
The control panel is programmed via the keypad on the control panel, accord­ing to the instructions on screen and the vocal guide provided in the main phas­es of programming.
General rules for programming:
• Modifications to settings must be confirmed by pressing the key OK; if not
confirmed, the modification is not saved.
• When the display shows the symbols
this means that the user can scroll up
through the list using key , or down through the list using key .
• When the display shows the symbol
O
K
this means that the user must con-
firm the operation by pressing OK.
• When the display shows the letters Y or N this means that the function is
active (Y = Yes) or not active (N = No).
• To exit a function, press ESC.
• To cancel a setting, press C.
• To cancel part of a setting during entry, press .
• To enter the hour, date, minutes and seconds, and wherever a numerical
entry is required, use the numerical keys.
• To associate telephone numbers with vocal and SMS messages, use the
numerical keys.
• To select groups A, B and C use respectively keys 1, 2 and 3.
In the event of errors during entries there are no serious consequences;. the appliance simply indicates the error with one or more beeps.
Take special care when using the function “DELETE” (followed by the request “DELETE - CONFIRM?”) which if confirmed will delete all settings!
6.1 - Initial start-up and configurations
When the battery is connected, the display lights up and the control panel firmware version code is shown on screen.
Press any key to display the function to select the language used in the control panel menus. Scroll through the languages using keys  and  and press OK to confirm. From here on, vocal instructions are given; the messages are stored in the sys­tem memory (located next to the GSM SIM card) and are in one language only, corresponding to the language of the manual supplied with the control panel. Memories with other languages are available on request.
6.1.1 - Safety codes: “factory code”, “user code” and “installer code”
The control panel has a factory code: “0000” to enable initial access to the pro­gramming procedure. This code must subsequently be modified, and the two codes below must be programmed:
user code
: (from 4 to 8 digits) enables activation of the manoeuvres and
access to a number of settings;
installer code: (from 4 to 8 digits) enables access to all settings but not to
manoeuvres.
Caution! - Do not forget these codes or the control panel will need to be opened (generating a “tamper” alarm), disconnect the power supply and re­connect, then initialise the system after entry of the factory code (this operation does not delete the settings made).
After entering the factory code the system requests entry of the current time and date for the internal clock. The internal clock is used in the event log and the timed programmer.
After also entering the user code and installer code, the first item of the program­ming menu is displayed. To display the other menu items, use keys  and .
6.2.1 - PHONE BOOK MEMORY
This section enables memorisation of the names and telephone numbers of persons who will receive alarm messages and technical system information. The phone book can store up to 63 names (items). Position number 64 can be
programmed exclusively with the number provided by the SIM card operator to display residual credit. Therefore, when the control panel is active, credit can be displayed automatically by pressing . For each item of the phone book, compile all fields (see Menu 2).
6.2 - Programming menus (see Menu 1)
MENU 2
NAME NUMBER MESSAGE SMS TECHNICAL SMS
(maximum 13 characters) name of the person or authority corresponding to the telephone number. (maximum 16 digits) telephone number to be dialled by PSTN or GSM telephone diallers. selects one or more vocal messages (see 6.6.2) to be sent to the specific telephone number when the event occurs. selects one or more SMS messages (see 6.2.3) to be sent to the specific telephone number when the event occurs. selects one or more technical SMS messages to be sent to the specific telephone number when the event occurs.
Event
control panel battery discharged detector battery discharged supervision failure and/or radio disturbance present (check event log) system armed (message only sent in response to arming via telephone) system disarmed (message only sent in response to activation via telephone) electrical mains failure message sent after a mains power failu­re lasting for the set time interval (see SETTINGS)
no GSM network coverage for more than 15 minutes (the message is sent on return of the GSM signal) no successful call on PSTN line (check for any interruptions on the fixed telephone line) periodic message to indicate that the system is running (mes­sage sent after a certain number of programmable hours; see SETTINGS)
SMS text
LOW BATTERY CONTROL PANEL LOW BATTERY PERIPHERAL SUPERVISION FAILURE OR SCANNER
CONTROL PANEL ARMED
CONTROL PANEL DISARMED
MAINS FAILURE On return of mains power: CONTROL PANEL MAINS RETURN NO GSM NETWORK
NO SUCCESSFUL CALL ON PSTN LINE
PERIODICAL CALL OK
HSCU1GC HSCU1G
11 22 33
44
55
6-
7-
86
97
24
MENU 3
Message
N° 1
N° 2
N° 3
N° 4
N° 5
N° 6
Type of alarm associated in factory
ALARM GROUP A,B,C: this regards all indoor and outdoor intruder detectors – example of message: “Warning: robbery alarm at home
of Rossi, via Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified). TAMPERING ALARM: all tamper-proof devices can trip this alarm – example of message: “Warning: tamper alarm at home of Rossi, via Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified). PANIC ALARM: alarm activated manually by the user via transmitter or keypad – example of message: “Warning: danger at home of Rossi, via Pascoli 10 Rome”; (the name of the person who activated the alarm is then specified). ROBBERY ALARM (or distress): alarm activated manually by the user via transmitter or keypad – example of message: “Warning: request for first aid at home of Rossi, via Pascoli 10 Rome”; (the name of the person who activated the alarm is then specified). TECHNOLOGICAL ALARM: alarm activated by technical sensors (smoke, flooding, and others) – example of message: “Warning: flooding alarm signal at home of Rossi, via Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified). LOW BATTERY ALARM signal to indicate low battery charge on one of the system devices – example of message: “Warning: low bat­tery on system of Rossi, via Pascoli 10 Rome”; the device with the low battery is then specified.
DIRECT ACCESS Enables (yes) or disables (no) the option for direct access from this number; i.e. the possibility of calling the control panel from a
mobile phone and enable operations without entry of the user code as the caller ID is recognised automatically by the system.
Notes for recording numbers in the phone book.
Telephone line check
: the control panel normally listens for the free PSTN line tone before making the call. If the line is disturbed, the control panel may not
detect a free line. Therefore, to cancel this check process, enter the symbol ✱ (press ) in the programming phase as the first digit of the telephone number.
Pause between numbers: if a pause occurs between one number and the next when dialling numbers, enter the symbol P (press ) at the point of the pause.
6.2.2 - MESSAGES VOCAL MESSAGES
This section enables the recording of vocal alarm messages to be sent to the respective numbers in the phone book (those associated with the message during the programming phase) 6 messages are available (plus message N° 7) for a total recording of max. 240 seconds.
Recording vocal messages
To record the various vocal messages associated with alarm events, proceed as described below, with reference to Menu 3 and the following warnings:
For messages N° 1 to N° 6.
Each of these messages proposes a specific event as set in the factory (see Menu 3). If the association is as required on the user’s system, during the procedure simply press OK to confirm; otherwise refer to the paragraph “Replacing the vocal event association”.
For vocal message N°1 - ALARM GROUP A, B, C.
The message is normally sent in the event of an alarm in any of the system group zones (A, B, C). However, during the procedure, some of these groups can be excluded so that the message is not transmitted (for example in the case of an external alarm). To exclude a group, press the number corresponding to the group: 1 = group A, 2 = group B, 3 = group C. Then confirm selection by pressing OK. The dis­play then shows the enabled groups. Note - The enable function applies only to the telephone transmission of the alarm message.
For vocal message N° 7.
This message is a reminder which is read by the control panel to the user when the latter calls the unit. If there are no domotic actuators, the message can describe normal control operations.
Example of message text:
- to check the control panel status, press: 0, #
- to disarm the control panel press: 0, ✱, 0, #
- for total arming of the control panel, press: 0, ✱, 1, #
- to activate system groups A and B press: 0, ✱, 2, #
If remote domotic actuators are envisaged (turning on lights, electrical appli­ance control etc.) the message must contain information on how to execute the various commands according to the actuators present (see 9.2.9).
Vocal message recording procedure:
01. From the menu MESSAGES press OK to confirm: VOCAL MESSAGES is
displayed.
02. Press OK again to confirm: VOCAL MESSAGE N°1 is displayed.
03. Select the required message using keys and and press OK to con-
firm. The text
O
K
TO RECORD is displayed.
04. Press and hold OK and start to record the message. During recording, the
remaining recording time is displayed.
05. At the end of recording, release OK. The control panel automatically
replays the message.
06. If required, listen to the message again by pressing OK.
07. If recording is successful, press ESC to confirm the recorded message and
exit the procedure.
08. If the recording is not satisfactory, press C to cancel and repeat the proce­dure.
This procedure can be used to record, re-listen to and modify the various mes­sages.
Replacing the vocal event association
A vocal massage can be associated with a different event from that set in the factory. During the message configuration phase, when the default associated event is proposed, simply select a different one using keys and . As well as the 6 proposed events, other events can be programmed if required (see Menu 4).
MENU 4
MAINS FAILURE (models HSCU1GC and HSCU1C only): the call is made after a programmable interval (see SETTINGS) of mains failure to the control panel from the electrical mains – example of message “Warning: power failure at home of Rossi, via Pascoli 10 Rome” PERIODIC CALL: the call is made after a programmable number of hours (see SETTINGS) to confirm correct operation of the control panel – example of message “Alarm system operation OK at home of Rossi, via Pascoli 10 Rome” TEMPERATURE: the call is made when the control panel temperature exceeds 70°C or falls below 5°C – example of message: “Warning: abnormal temper­ature at home of Rossi, via Pascoli 10 Rome” Special event alarm ( display _ _ _ _ _ / _ _ _ _ _ ). A special alarm can be programmed to generate a call when a special event occurs. Possible events are:
ALL allarm OPEN door left open
SIM expiry warning message (programmed expiry, see SET­TINGS)
SIM VALIDITY
10 8
25
26
6.2.3 - MESSAGES SMS MESSAGES
This section enables writing of SMS messages to be sent to the respective numbers in the phone book (those associated with the message during the programming phase) a maximum of 6 messages are available.
Recording SMS messages
To record the various SMS messages associated with alarm events, proceed as follows:
01. From the menu MESSAGES press OK to confirm: the text VOCAL MES- SAGES is displayed.
02. Press : SMS MESSAGES is displayed; press OK to confirm.
03. Press OK again to display SMS MESSAGE N°1.
From here onwards the operations are the same as those for the vocal messages with the difference that SMS messages are text only and must be written using the alphanumerical keypad, in the same way as on a nor­mal mobile phone. The maximum text length is 24 characters.
BATT battery low DISARM. disarming IN A (or B or C) arming of specific group ARM activation SUPERV supervision alarm SCAN scanner alarm END AL door reclosed MAN tamper alarm TEMPERATURE hot/cold temperature alarm
To program an alarm, the event must be written in the first section of the display (example: to write “low battery” enter BATT and press OK to confirm); then in the second section, write the nome assigned to the device that generates the event (see EXTRAS): for control panel write CONTROL PANEL and press
OK to confirm. NO EVENT: no call is made on confirmation of this event (used for example to temporarily disable an alarm)
26
6.2.4 - EXTRAS
This menu enables the configuration of system devices on the control panel.
6.2.4.1 - EXTRAS REMOTE CONTROLS
The remote control menu enables configuration of hand-held transmitters used to arm and disarm the control panel. Each remote control can be programmed to arm or disarm all or only some of the groups A, B and C. To program a transmitter, proceed as follows:
01. From the menu EXTRAS press OK to confirm: REMOTE CONTROLS is dis-
played
02. Press OK again to confirm: REMOTE CONTROL 1 is displayed (or the first
free space).
03. Press OK again to access the groups activated or deactivated by this
remote control.
04. Use keys 1, 2, and 3 to set groups A, B, C to ON, and keys 4, 5, 6 to set to OFF.
05. Press OK again to confirm:
The specific parameters of the remote control must then be entered, starting with memorisation in self-learning mode.
06. Press the keys OFF and ON simultaneously; a confirmation beep is emitted (if the remote control is already memorised, 3 Beeps indicate an error).
07. Press OK again to confirm memorisation,
08. Use the alphanumerical keypad to write a text that enables recognition of
the transmitter (normally the owner’s name – maximum 9 characters). On completion, press OK to confirm.
09. Record the vocal message for transmitter recognition; press and hold OK during recording.
10. If recording is successful, press ESC to confirm the recorded message and exit the procedure.
Repeat the same procedure for all remote controls to be programmed on the system (maximum 32 remote controls).
11. To delete a programmed remote control, select it, press C and then press OK to confirm deletion.
6.2.4.2 - EXTRAS CODES
The codes menu enables configuration of the numerical codes (5 digits) used to arm and disarm the control panel, via the keypad on the control panel or other keypads as required. Each user should have a personal code. This enables tracking of the precise identity of who performed the operation recorded in the event log. To configure the codes, proceed as follows:
01. From the menu EXTRAS press OK to confirm: REMOTE CONTROLS is dis- played
02. Press : CODES is displayed; press OK again to confirm: CODE 1 is dis- played (or the first free space).
From here onwards, the operations are the same as those for the remote controls, with the difference that the codes must be entered on the keypad.
Note for ANTIDURESS function
This function enables deactivation of the alarm, for example when under threat, by entering a different code from the normal version, but which activates the robbery alarm at the same time.
01. When the control panel displays the option UNDER THREAT, if the user wants the previously entered code to be used as the Under Threat code, activate the function by pressing (the symbol N on the screen becomes Y) and press OK to confirm; otherwise to leave the function disabled, press OK.
Repeat the same procedure for all codes to be programmed using this function (maximum 32 codes).
02. To delete a programmed code, select it, press C and then press OK to confirm deletion.
6.2.4.3 - EXTRAS ALARM GROUP A (or B or C)
In the alarm menu, detectors can be memorised one by one, as planned and associated with a specific group. Therefore first select the required group (the procedure below uses group A as an example) and memorise the detectors as follows:
01. From the menu EXTRAS press OK to confirm: REMOTE CONTROLS is dis- played
02. Press twice : ALARM GROUP A is displayed; press OK to confirm.
03. The second line displays EXT AL N
04. If the user wants an alarm in group A to trip an outdoor alarm, activate the
function by pressing (the symbol N on the screen becomes Y) and press OK to confirm; otherwise to leave the function disabled, press OK.
05. SENSOR A01 is displayed (or the first available number); use keys to select the planned number of the sensor to be memorised and press OK to confirm.
06. The second line displays DELAY IN N AND N: this factory setting (symbol N on display) indicates that there is no
delay (the sensor trips the alarm imme-
diately) and there are no
2 sensors envisaged with AND in between. At this point the first or second function can be activated as required (or also both) using respectively keys 1 or 2 (the symbol N on display changes to Y). Press OK to confirm:
07. If the input delay
function has been enabled, the system request entry of
the delay time (from 0 to 99 seconds). Use the numerical keypad to enter the required time and press OK to confirm.
08. The second line displays INSERT BATTERY: this indicates that the battery must be inserted in the detector.
09. After inserting the battery, the detector performs a number of transmissions and the control panel emits a beep to indicate that the detector has been memorised correctly. If the function AND was previously enabled, the bat­tery must now be inserted as well as the second sensor for relative memo­risation. Press OK to confirm.
10. LABEL A01 is then displayed; use the alphanumerical keypad to write a text to enable detector recognition (maximum 9 characters). On comple-
MENU 5
ON – OFF
PULSE
Toggle function, switching to ON or OFF according to the setting of an internal clock (see 9.2.7); or from a command via telephone Switches to ON for a time settable from 0 to 999 seconds according to the setting of an internal timer program (TIME ON); or from a command via telephone
6.2.5 - SETTINGS
This menu enables configuration of a number of control panel functions.
6.2.5.1 - SETTINGS EXCL. SENSORS
One or more sensors can be deactivated (for example in the event of a mal­function). To deactivate a sensor, proceed as follows (the user code can also be used to access the menu):
01. From the menu SETTINGS press OK to confirm: EXCL. SENSORS is dis-
played
02. Select the required sensor using keys and and press OK to confirm.
03. INCLUD is displayed on the second line; if the sensor is operative, or
EXCLUD if the sensor is disabled.
04. To change the status use keys and and press OK to confirm.
Note - Deactivation does not delete the sensor but simply enables the system
to ignore any alarms sent by the sensor (these alarms are not recorded in the event log).
6.2.5.2 - SETTINGS EXCL. WIRED INP.
For wired inputs on the control panels HSCU1GC and HSCU1C, refer to the previous paragraph (SETTINGS  EXCL. SENSORS).
6.2.5.3 - SETTINGS RELAY1 SETTINGS (or RELAY2)
The control panels HSCU1GC and HSCU1C are equipped with 2 relay outputs. Output RELAY 1 is factory set for the ON-OFF function Output RELAY 2 is factory set for the GENERAL ALARM function. These set­tings can be modified with one of the functions specified in Menu 5. To modify, first select the relative relay (the procedure below uses relay 1 as an example) and proceed as follows:
01. From the menu SETTINGS press OK to confirm: EXCL. SENSORS is dis- played
02. Press  twice (or 3 times if programming relay 2): RELAY1 SETTINGS is displayed; press OK to confirm:
03. (ON-OFF appears on screen) Use keys , to select the required function. Note – In the case of the function PULSE, the second line displays the
time; therefore use the numerical keys to enter the required value.
04. On completion, press OK to confirm.
tion, press OK to confirm.
11. Record the vocal message for detector recognition; press and hold OK
during recording.
12. If recording is successful, press ESC to confirm the recorded message and
exit the procedure.
Repeat the same procedure for all detectors planned for group A.
Note on memorisation of detectors
Once a detector is memorised and associated with a specific group, it can no longer be memorised in other groups. If an association is to be subsequently changed, a detector can be deleted and then memorised in a different group.
• To delete a detector, select it, press C and then press OK to confirm deletion.
As well as the alarm group A, groups B and C are also available. To memorise the detectors planned and associated with these groups, perform the same operations as per group A.
6.2.4.4 - EXTRAS 24H PANIC AL. (or 24H ROBBERY, or 24H TECNOL.)
As well as the 3 alarm groups A, B and C (which can be activated or deactivat­ed as required), other constantly active groups are also available as follows:
- PANIC: group used to program keys of remote controls or keypads for man­ual alarm activation.
- ROBBERY: group used to program keys of remote controls or keypads for manual telephone alarm calls or requests for first aid.
- TECHNOLOGICAL: group used to program technical alarm detectors (smoke, flooding, gas, etc.)
6.2.4.5 - EXTRAS 24H PANIC; EXTRAS 24 ROBBERY
To program the keys of the remote controls or keypads in the groups PANIC and ROBBERY, after selecting EXTRAS 24H PANIC ( or 24H ROBBERY) the same procedure is performed as per memorisation of the remote controls, with the difference that the key must be held for at least 10 seconds to complete memorisation.
6.2.4.6 - EXTRAS 24H TECHNOL
To program the detectors in the TECHNOLOGICAL group, select EXTRAS 24H TECHNOLOGICAL, and perform the same procedure as described for programming group A.
In all the control panel can memorise up to 99 detectors in the various groups (2 detectors in AND mode are considered as 1); this calculation also includes the bidirectional sirens and remote control keys with panic and robber functions or .
6.2.4.7 - EXTRAS WIRED INPUTS
The control panels HSCU1GC and HSCU1C are fitted with a terminal board with 6 inputs for the same number of lines to which detectors can be connect­ed (with NC contact output); they also have 3 tamper inputs (NC contact). For details of connections, see chapter 5.
The presence of these inputs is recognised by the control panel in self-learning mode. If the inputs are then to be cancelled, simply set the control panel Test function and eliminate connections. These inputs are factory set with the following standard associations (the asso­ciation can be changed at any time as required):
Input Association
A1 1stinput of alarm group A A2 2ndinput of alarm group A TMPA Tamper of group A B1 1stinput of alarm group B B2 2ndinput of alarm group B TMPB Tamper group B C1 1stinput of alarm group C C2 2ndinput of alarm group C TMPC Tamper group C
As in the case of detectors connected via radio, the following can also be pro­grammed for each of those wired to the inputs:
• The associated alarm group (A, B or C)
• The input delay time
• Text label
• A vocal recognition message
Each tamper input can be associated with:
• The associated alarm group (A, B or C)
For these settings, perform the same procedure as described for programming group A.
6.2.4.8 - EXTRAS
EXTERNAL KEY
The control panels HSCU1GC and HSCU1C are fitted with a KEY input on which a contact can be connected for control panel arming or disarming; arm­ing can be total or partial according to the setting. The contact must be: closed, for control panel disarmed and open, for control panel armed. The control panel switches its status according to changes in the status of the contact, but it can be subsequently controlled by other devices, such as remote controls with which the control panel can be disarmed even when the KEY contact is open.
To program this input, perform the same procedure as described for transmitter memorisation.
27
GENERAL ALARM TAMPER PANIC ROBBERY TECHNOLOGICAL ANOMALY
ARM./DISARM INP. DELAY
Switches to ON for 3 minutes in the case of a general alarm (excluding antiscanner) Switches to ON for 3 minutes in the case of a tamper alarm Switches to ON for 15 seconds in the case of a panic alarm Switches to ON for 15 seconds in the case of a robbery alarm Switches to ON for 15 seconds in the case of a technological alarm Switches to ON for 15 seconds in the case of low batteries (of control panel or detectors), supervision failure, radio distur­bance with system activated (antiscanner), GSM network failure Switches to ON on activation and OFF on deactivation (useful for connecting an “alarm active” indicator light) Switches to ON during the input delay set on one or more detectors
28
6.2.5.4 - SETTINGS RADIO OUTPUTS
The control panels are equipped with 16 radio outputs. These are sent via radio to receivers set up for the control of motors for rolling shutters, lighting control or electrical appliances (for example, HSTT2N and HSTT2L). These commands can be activated exclusively via telephone calls to the control panel; however these receivers can also be controlled directly with transmitters or keypads, by memorising the control keys accordingly. In terms of the receivers, the control panel acts as a radio control transmitter; therefore these controls must be memorised in self-learning mode on the receiver. There are two types of command: PULSE (each command switches the receiv­er output for the time as set on the receiver) or ON-OFF (i.e. one command for ON and one for OFF). To configure these radio commands, proceed as follows:
01. From the menu SETTINGS press OK to confirm: EXCL. SENSORS is dis-
played.
02. Press four times : RADIO INPUTS is displayed; press OK again to confirm.
03. RADIO 1 appears on screen; use keys , to select the required com-
mand number.
04. The second line displays PULSE (this can change from ON-OFF using keys ).
05. Before confirming, set up the receiver to receive the code for the self-learn­ing function (see the specific receiver instructions).
06. Press OK to program the receiver (this confirms the operation).
Repeat the same procedure to program all required commands and relative receivers.
6.2.5.5 - SETTINGS
The settings menu also enables the configuration of a number of special parameters and functions, used to optimise operation of the control panel in specifnel Menu 6.
6.2.6 - DIGITAL PROTOCOLS
(advanced setting, without vocal guide)
This menu enables the configuration of the protocols for connection with the alarm receiving centres CONTACT ID and CESA 200 BAUD. To program the parameters of these protocols, request a copy of the specific manual “Digital Protocols” from the Nice Service Centre.
6.2.7 - PC REMOTE MANAGEMENT
(advanced setting, without vocal guide)
The control panel enables remote technical assistance. For this function, the control panel must be connected to the PSTN telephone network, while the service centre must be equipped with the relative HSMO telephone modem and relative software for PC Tele Service. Remote assistance must in any event be explicitly activated by the user by pressing the “spanner” key. To program the parameters required for remote technical assistance, refer to the relative manual of the HSMO telephone modem.
Enable selection of priority between GSM and the PSTN line for emergency calls. Enables the delivery of SMS messages in the event of a mains power failure and programming of a standby time in min­utes prior to delivery. Enables the delivery of periodic SMS messages and programming of the frequency of delivery in hours. Enables the delivery of SMS messages warning of SIM validity expiry and programming of the remaining validity in months. Enables update of the system time and date; these data are used to program timed functions and the event log. Enables entry and specification on the control panel of a number for access to the PSTN network, if an alarm receiving centre is present. For increased safety, it is preferable not to connect the control panel to a switchboard but connected directly to the line. Enables checks and changes to the installer access code. Enables activation of the function ANTISCANNER and the definition of the time interval of disturbance to be considered negligible (from 1 to 60 seconds) The control panel checks the radio disturbance signals in the environment; when the set time interval elapses, the control panel siren alarm is activated (for 30 seconds) as well as the SIR terminal output. Enables the SUPERVISION function, i.e. a system check that all devices are running, transmitted approximately every 40 minutes. Absence of the signal for over 3 hours by a device generates the specific signal and each time the system is switched on or off. Enables entry of the time between activation and effective operation of the alarm system. This is factory set at 60 sec­onds. The user is recommended to avoid excessively short intervals to avoid rushed exits. Enables deactivation of automatic control of daylight saving time. Enables selection of permanent display lighting. This function significantly reduces autonomy of the control panel in the event of a power failure. Enables adjustment of the volume of the control panel vocal guide. If the volume is set to zero, the vocal Activation/Deac­tivation notification messages are also disabled. Enables the function for arming the control panel (totally or partially) at a precise time. Disarming is manual only. Displays the control panel firmware version. Enables total deletion of all control panel parameters, including the event log. Caution: this operation is not reversible.
MENU 6
GSM/TELEPHONE LINE MAINS FAILURE
PERIODIC CALL SIM VALIDITY TIME AND DATE TEL. EXCHANGE
INSTALLER CODE ANTISCANNER
SUPERVISION
EXIT TIME
AUTO SUMMER H BACKLIGHTING
VOLUME
FORCED ARMING FW VERSION SYSTEM RESET
In general, the products in the range Nice Home Security do not require special maintenance; in any event the surfaces of the products should be cleaned, and in particular of the detectors, on which the sensitive elements (sensors) must be kept free of dust and other contaminating substances at all times (see respec­tive instruction manual).
Warning – For cleaning the product surfaces, use a slightly damp (not wet) cloth; use water only and never detergents or solvents.
An alarm system does not normally signal alarm conditions for extended peri­ods of time and for this reason correct operation is not always verified.
The control panel is equipped with a series of functions to maintain and check system efficiency:
• Possibility of checking components in the alarm system by means of the sys-
tem “TEST” function (see chapter 9.2.5). Periodic checks of system opera­tion are recommended.
• The control panel records all events and stores the last 200 events in the memory (see chapter 9.2.5.1). The analysis of the event log can be useful to check and possibly prevent the causes of malfunctions.
• The control panel indicates the charge level of a number of associated devices. All battery-powered devices have a function that checks the battery charge status; when the remaining autonomy is approx. 15-30 days, the “low battery” status is indicated. This occurs both on the device (see respective instruction manual) and on the control panel.
Warning – When the low battery signal is present, the battery must be replaced as soon as possible.
• The mains-powered devices have a rechargeable backup battery (not sup­plied) which is activated in the event of a power failure. The average lifetime of this battery is 4-7 years (decisive factors include environmental temperature, frequency and intensity of use).
It must be replaced at the end of this period. Otherwise a practical test of sys­tem duration must be performed: disconnect the mains power supply and check how long afterwards the low battery signal is activated. Replace the battery when the time is half that of the normal value or less than the required service time.
Caution! – When batteries are partially discharged, the radio range between devices is reduced and system operation is not guaranteed.
7.1 - Replacing the batteries (control panel and accessories)
When the battery pack or backup battery of the control panel or those in the accessories are discharged, they must be replaced to restore efficient system operation.
Caution! – Never use new battery models different from the specified version.
To replace the control panel battery proceed as follows:
Caution! – Before opening the control panel housing, to avoid undesired activation of alarm signals, the unit must be set to TEST mode
(see chap­ter 9.2.5.1) and the mains power must be disconnected (for models HSCU1GC and HSCU1C).
For models HSCU1GC and HSCU1C (backup battery):
01. Open the box (fig. 41);
02. Detach the backup battery from its seat (fig. 42) and replace with an iden-
tical version. Caution! – Observe the indicated polarity;
03. Close the box (fig. 44);
For models HSCU1G
and HSCU1 (battery pack):
01. Open the box (fig. 41);
02. Detach the battery (fig. 43) and replace with an identical version.
03. Connect the new battery:
04. Close the box (fig. 44);
After closing the control panel, restart the control panel and reprogram at least the time and date for the internal clock (see chapter 6.1).
PRODUCT MAINTENANCE
7
x 4
41
29
42
x 4
44
only for models HSCU1GC and HSCU1C
43
only for models HSCU1G and HSCU1
30
31
DISPOSAL
Product disposal
All devices in the alarm system are an integral part of the installation and must be disposed of as a whole. As in installation, also at the end of product lifetime, the disassembly and scrapping operations must be performed by qualified per­sonnel.
These products comprise various types of materials: some may be recycled others must be disposed of. Seek information on the recycling and disposal sy ­stems envisaged by the local regulations in your area for this product category.
Caution! – Some parts of the products may contain pollutant or hazardous substances which, if disposed of into the environment, may cause serious da ­mage to the environment or physical health.
As indicated by the symbol alongside, disposal of this prod­uct in domestic waste is strictly prohibited.
Separate the waste into categories for disposal, according to the methods envisaged by current legislation in your area, or return the product to the retailer when purchasing a new version.
Caution! – Local legislation may envisage serious fines in the event of abusive disposal of this product.
Disposal of batteries
Caution! – The backup batteries and battery packs in the devices present
in this alarm system, also if discharged, contain pollutant substances and therefore must not be disposed of as household waste. Dispose of according to separate waste collection procedures as envisaged by local current standards.
• A detector occasionally generates an improper alarm: – check whether the batteries are discharged;
ensure that the detector is not dirty or damp.Check the specific instructions for each type of sensor for the possible caus-
es of improper alarms and act accordingly. If the improper alarms persist, place a second detector in the same area to be controlled and memorise, associating it with the first, using the AND function.
HSDID11:
Door and window opening detector
- Incomplete door/window closure: if the door or window is not perfectly closed, the wind may move it.
- Door/window deformation: check the correct distance between the sensor and magnet with the door/window closed
- Vibrations: the internal anti-intruder sensor is sensitive to strong vibrations
- External contact: the connection to the external contact is sensitive to high levels of humidity
HSDIM11:
Infrared detector with volumetric lens
HSDIM12: Infrared detector with curtain lens
- Strong currents of hot or cold air: the infrared sensor is sensitive to hot mov­ing bodies
- Large insects: for the sensor, a bumblebee of one centimetre would be like an elephant at a distance of 10 metres
- Vibrations: the internal anti-intruder sensor is sensitive to strong vibrations
- External contact: the connection to the external contact is sensitive to high levels of humidity
HSDIS01 :
Fine volatile combustion powder detector
- Cooking fumes and vapours: place the sensor far from cooking areas
- Dust: avoid positioning the sensor in dusty environments
HSDID01 :
Glass breakage sensor
- Falling objects: can cause noise similar to breaking glass
- Rapid pressure changes: the activation of air conditioners or fans can gener­ate improper alarms.
HSDIW01 :
Flooding detector
- Condensation or high levels of humidity: high levels of humidity can produce condensation on the sensor
- Dirty sensor: dirt increases the risk caused by humidity
TROUBLESHOOTING... (troubleshooting guide)
8
• Even when passing in front of a volumetric sensor, no alarm signal is triggered: once a volumetric has transmitted the first alarm, it will not transmit
another if repeated within 3 minutes. Wait for at least 3 minutes and then try again.
The display shows: DISARM AND INSERT SIM Check that the SIM card is inserted correctly; ensure that it has not expired (some operators deactivate the SIM cards after a certain period of disuse) and in the case of pay-and-go mobile phones, check that there is residual credit.
• The phone dialler test is negative
The call is only made if the vocal message has been recorded; check by listen­ing to the call, that the message has a vocal content.
• For all products in the Nice Home Security system
Virtually all products are fitted with protection against opening and removal; this system normally acts on the cover and base of the product. Inadequate fixture or incorrect closure of the covers could cause an alarm signal; this is a rare case for example in the case of temperature variations.
32
9.1 - Tips when using the system
• Always activate the alarm.
• Always close doors and windows.
• Never leave evident signs that there is no one at home, for example a full let-
ter box.
• If absent for long periods, remember to use the system functions that simu-
late your presence: for example use the internal timed programmer to tem­porarily open shutters or switch on some internal lights.
• At regular intervals change the alarm deactivation code without divulging it to
others.
9.2 - Operations available to the user
9.2.1 - Total alarm system activation
Via the control panel keypad: enter the numerical code then press the red
key twice
Via the supplementary keypads: enter the numerical code then press the
red key once
Via the remote controls: press the key once.
• Automatic total alarm system activation can be programmed at a set time as
required (see 6.2.5.5).
• Total alarm system can also be activated remotely, by means of a telephone
call (see 9.2.9).
9.2.2 - Partial alarm system activation
Via the control panel keypad: enter the numerical code then press the red
key once. If zone A, B or C is not to be activated, press respectively keys 1, 2, or 3 to disable, then press the key once.
Via the supplementary keypads: enter the numerical code, then if zone A,
B or C is not to be activated, press respectively keys 1, 2, or 3 to disable, and press the key once.
Via the remote controls: press the key ( ) to activate zones A+B. If the
remote control is duly configured, press the key ( ) to activate zones B+C.
• Automatic partial alarm system activation can be programmed at a set time
as required (see 6.2.5.5).
• Partial alarm system can also be activated remotely, by means of a telephone
call (see 9.2.9).
9.2.3 - Alarm system deactivation
Via the control panel keypad: enter the numerical code then press the
key once.
Via the supplementary keypads: enter the numerical code then press the
key once.
Via the remote controls: press the key once.
9.2.4 - Alarm system deactivation under threat (anti-duress)
Via the control panel or supplementary keypads: if the alarm system is
deactivated by entering a special “antiduress” code, the alarm system is deactivated and specific telephone calls are transmitted automatically as envisaged for the robbery alarm.
Caution: if an alarm is in progress, the corresponding GSM calls may cause problems with deactivation of the alarm system via the supplementary keypads or remote controls. In this case the alarm system should be deactivated via the control panel keypad.
9.2.5 - Control panel test
The control panel test function enables a number of checks on system opera­tion. For example the CONTROL PANEL TEST mode is useful to open devices and change the batteries, as in these conditions the sirens are temporarily dis­abled. There are 3 types of test:
- CONTROL PANEL test: enables the user to check operation of all detectors
and quality of the radio signal received.
- PHONE DIALLER Test: enables delivery of one of the recorded messages
on the fixed PSTN or GSM line.
- FIELD METER Test: enables the user to check signal intensity on the 2 fre-
quencies used by the system.
To activate the test modes, proceed as follows:
01. With the control panel disarmed, enter the user code and press .
02. The word TEST is shown on the first line of the display and CONTROL
PANEL on the second line.
03. Press OK to confirm and proceed with the control panel test or use keys
and to display the other types of test. Press OK again to confirm.
04. According to the type of test selected, proceed according to the procedure
in one of the following three paragraphs.
9.2.5.1 - CONTROL PANEL test
05. Generate a detector alarm by opening protected doors and windows or moving within the area protected by the volumetric detectors etc.
06. Wait for at least 5 seconds between one alarm and the next; on completion ensure correct reception of each alarm, scrolling through the list on screen using keys .
Example: if the display shows:
ALL SENSOR 03 C1H C2M
this means:
ALARM alarm
SENSOR name assigned to detector
03 progressive number (3rd event detected)
C1 H radio signal on frequency C1 high (H = high)
C2 M radio signal on frequency C2 medium (M = medium)
The quality of the signal depends on the distance between devices and any obstacles present; the signal is encoded on 3 levels: H (high) ; M (medium) ; L (low) . These 3 levels are sufficient to guarantee correct operation of the detec­tor. If one
frequency has no display, the detector is probably outside the maxi­mum range or there is disturbance on this frequency; in any event a single fre­quency should still be sufficient to guarantee correct system operation. However if both
frequencies display nothing, a practical test must be made by arming the control panel and generating the alarm. Technical practices envis­age the TEST when the signal is weak: in normal conditions the system should continue to be operative. A detector signal may at times by high (H) and at others medium (M): this may depend on random interference or the movement of persons in the area during testing. This often occurs with remote controls as their position with respect to the control panel can easily change.
Notes on control panel testing:
- Some detectors transmit the alarm twice; therefore there may be two con-
secutive signals on the list.
- Once a volumetric detector has transmitted the first alarm, it will not transmit
another if repeated within 3 minutes. To perform the test, there must not have been persons within the protected area for at least three minutes. This block, on repetition of the alarm within 3 minutes, is not present if the detector bat­tery compartment is open. Therefore the test should be performed with the battery compartment open.
9.2.5.2 - FIELD METER test
05. Transmit a radio signal using any device and immediately check intensity of
the signal received for the 2 frequencies.
Example: if the display shows:
C1: ❚❚❚❚❚ C2: ❚❚❚❚
this means:
C1 signal on frequency 433 MHz: excellent (*)
C2 signal on frequency 868 MHz: very good (*)
(*) Note – The signal is sufficient if more than one bar is displayed.
9.2.5.3 - PHONE DIALLER test
05. Dial the number to be called and press OK to confirm:
06. Using keys and select the message to be sent and press OK to con-
firm.
07. Using keys and select whether to use the PSTN line or GSM network.
08. Press OK again to confirm: the call is made.
09. The message should be heard clearly from the number called.
9.2.6 - Event log
The control panels record all events occurred (arming, disarming, alarms etc.), memorising the date, time, name of the person performing the operation and the device concerned.
The memory stores the last 200 events; these are queued, and the 201st event then overwrites the 1st and so on. To check the event list, proceed as follows:
01. Enter the user code and press .
02. The display shows the most recent event; the first line shows the date and
time and the second line displays a description of the event. The events are shown in abbreviated form; for an explanation of their meanings, refer to examples 1, 2 and 3.
03. To display the other events, use keys and .
04. To quit, press ESC.
OPERATION INSTRUCTIONS
9
33
9.2.7 - Timed program
The control panels HSCU1GC and HSCU1C are equipped with 1 relay output whi ch can be used to control electrical appliances. Activation can be via a com­mand sent by means of a telephone call (see 9.2.9) or automatically at a set ti ­me. In this case the activation start and end time can be programmed as follows:
01. With the control panel disarmed, press ESC.
02. The first line of the display shows TIME ON : 00:00; the second line dis-
plays TIME OFF: 00:00.
03. Use the numerical keys to enter the required times and press OK to con-
firm.
After programming the times, the function is enabled by pressing the UP arrow key [] in the main menu when the control panel is disarmed. The top left cor­ner of the display shows the symbol “H” to indicate that the timed program is active and the relay output will therefore be activated every day at the set times. To disable the timed function press the DOWN arrow key [] (the “H” symbol disappears from display).
9.2.8 - Remote assistance
If the installer has the specific telephone modem, a PC and relative software, the control panel can be controlled at a distance to analyse and solve any problems.
The remote control must be activated by the user by pressing the holding the
key for more than 5 seconds so that the control panel makes the call the telephone number entered by the installer. During connection, the user must avoid intervening on the control panel keypad to avoid any conflict. The user can still monitor operations in progress on display.
Warnings for the installer - A special access code can be configured (in the Remote management menu) to enable automatic access by the installer to the control panel. However the installer must bear in mind that this operation can be performed without the presence of the user and that it causes system deac­tivation (though only temporary). As this is the specific responsibility of the installer, a previous agreement is recommended between the installer and user to authorise use of the remote assistance provision without the user. In any event the user can disable this function at any time by cancelling the access code.
9.2.9 - Remote use
All control panels can be called via the telephone, on the fixed line, by dialling the relative number. The control panel HSCU1GC can also be called on the GSM network, by dialling the number of the SIM card used. The control panel HSCU1G, though equipped with the GSM module, cannot receive calls as this module is normally switched off to reduce battery con­sumption.
EXAMPLE 1 - key
Display Meaning
(1) date/time of event (2) INSTALL access to menu with installer code
USER access to menu with user code NO PSTN LINE no connection to PSTN telephone line NO GSM NETWORK no connection to GSM network MAINS FAILURE no power supply from mains CHANGE NUM. modification via SMS of a phone number in phone book GSM CHECK GSM activation-deactivation procedure
EXAMPLE 2 - key
Display Meaning
(1) date/time of call (2) outgoing call
incoming call
(3) V vocal message
S SMS message D message in digital protocol
(4) (name) name of call recipient (stored in PHONE BOOK)
CONTACT ID call to alarm receiving centre INSTALLER remote assistance call CUST. SERV. call from service centre
(5) OK call successful
KO: call failed OC call failed as engaged NO: call failed as no answer
EXAMPLE 3 - key
Display Meaning
(1) date/time of event (2) ARM total arming
IN A (or B or C) partial arming DISARM disarming EXT AL external alarm OPEN door/window open TAMPER tampering ALARM alarm PROGR. programming SUPERV supervision failure SCAN radio disturbance BATT battery discharged DELETE deletion EXCLUD out of service INCLUD in service Xxxxx (label) name assigned to peripheral
(3) TEL remote control
COD keypad code DET sensor/detector WIR wired input USER access to menu with user code INSTAL access to menu with installer code REMOTE intervention via remote telephone
16/05/07 19:59
INSTAL
(1) (1)
(2)
EXAMPLE 1
16/05/07 09:32V M
ARCO OK
(1)(2) (3)(1)
(4) (5)
EXAMPLE 2
16/05/07 18:20
INSER TEL01
(1) (1)
(2) (3)
EXAMPLE 3
3434
Querying control panel status with vocal reply Total arming and vocal confirmation Partial arming (zones A+B only) and vocal confirmation Disarming and vocal confirmation
(*) Activation of relay N° 1 (*) Deactivation of relay N° 1
Check of status of relay N°1 (3 Beeps = relay active; 1 Beep = relay deactivated)
(*) Activation of relay N° 2 (*) Deactivation of relay N° 2
Check of status of relay N°2 (3 Beeps = relay active; 1 Beep = relay deactivated) Delivery of radio control ON command to receiver N° XX (enter digit from 1 to 16) Delivery of radio control OFF command to receiver N° XX (enter digit from 1 to 16)
(*) Note - the command sent with a telephone call has priority over other envisaged commands; for example timed set­tings of relay 1.
TABLE A
0 # 0 1 # 0 2 # 0 0 # 2 0 1 # 2 0 0 # 2 0 # 2 1 1 # 2 1 0 # 2 1 # X X 1 # X X 0 #
Calling the control panel on the fixed line
Caution! - To answer incoming calls on the PSTN line, the guide message N° 7 must be present (see paragraph 6.2.2); without this message, the control panel ignores the call.
To call the control panel, proceed as follows:
01. Dial the control panel telephone number.
02. Interrupt the call after the second ring
.
03. Call again immediately. the control panel answers with vocal message N° 7.
04. After listening to the message, enter the user code on the telephone key-
pad, followed by the symbol #.
05. Then enter the command required (see Table A).
Calling the control panel on GSM module (HSCU1GC only)
The GSM module responds immediately to the incoming calls only if the called ID is recognised (the telephone must be enabled to send its own ID). It is also possible to avoid sending the user code, by enabling direct access for specific caller numbers (see PHONE BOOK – DIRECT ACCESS). If the caller phone does not send its own number, or if the number is not enabled for direct access, refer to the previous procedure “Calling the control panel on the fixed line” for calling the GSM module.
9.2.10 - User called by the control panel
In the event of an alarm, the control panel makes the envisaged telephone calls. Those called can interact with the control panel, for example to disarm it by entry of the command described in Table A. Those called by the control panel can interrupt the cycle of envisaged calls (consecutive); to stop the calls, listen to the message and the end confirmation beep and then press the # key on the telephone.
9.2.11 - Remote listening
Both when called by the control panel and when the user calls the control pan­el, during connection on the PSTN fixed line, the user can listen to the environ­mental noise captured by the control panel microphone. To enable this function, press on the telephone. Press again to stop listen­ing and proceed with sending any commands as required. If no operation is performed, the call is terminated after 60 seconds from ending the remote lis­tening function.
9.2.12 - Hands free conversation
(HSCU1GC and HSCU1G only, with control panel disarmed)
Both when called by the control panel and when the user calls the control pan­el, during connection on the GSM network, the user can set communication to hands-free mode from the microphone and loudspeaker of the control panel. To enable this function, press on the telephone. Press again to stop listen­ing and proceed with sending any commands as required. If no operation is performed, the call is terminated after 60 seconds from ending the remote lis­tening function.
A telephone call can also be initiated using the built-in GSM. To enable this function, proceed as follows:
01. Press the key ( ) to connect.
02. Dial the number to be called and press OK to confirm:
03. To terminate the call, press ESC or the key ( ).
Caution! - The control panel HSCU1G enables the call, but the user must wait for the GSM module to switch on and connect to the network.
9.2.13 - Remote modifications to stored telephone numbers
(HSCU1GC only)
It is possible to change the phone numbers in the phone book by means of an SMS message sent from a telephone memorised and enabled for direct access. To perform this operation, write the SMS message without spaces
as follows: A[old number to replace]A[new number to enter] for example: A333555666A333777888
The control panel sends the following confirmation SMS message: “CHANGE MADE *333777888*”
9.2.14 - Other functions on the GSM module
The control panels with GSM module offer other automatic functions (if pro­grammed by the installer), such as:
• SMS notifying of absence and return of mains power (HSCU1GC only).
• SMS for periodic notification that the control panel is operating correctly.
• SMS notifying of SIM expiry.
• SMS notifying of low battery charge in devices.
• SMS notifying of control panel arming/disarming.
9.2.15 - Residual credit on SIM
Press to make an automatic call to the service centre of the telephone oper­ator and listen to an automatic message informing the user of the residual cred­it on the SIM card (the function must be configured accordingly (see 6.2.1).
3535
TECHNICAL SPECIFICATIONS
Power supply Insulation Backup battery Backup battery autonomy
External battery Absorption (12Vdc) Power supply output Wired alarm inputs Wired anti-tamper device Control inputs Wired alarm outputs Wired outputs Weight
Power supply Insulation Absorption
Autonomy
Weight
GSM telephone connection
Additional functions
Alarm via radio inputs
Anti-tamper via radio Alarm via radio outputs Radio system anomalies Event log Timers Displays Commands Internal siren and indicator Acoustic signals
Vocal guide Radio reception/transmission Radio range Fixed PSTN telephone connection Dimensions Operating temperature
Technical specifications for models HSCU1GC and HSCU1C
230 V ~ 50 Hz; maximum power 35 W Class II (no earthing connection required) 12V – 2.2Ah lead rechargeable (not supplied) With battery charged, approx. 36 hours; autonomy estimated with operation on stand by and without absorption on wired connections. An external battery can be connected (maximum 12 V - 6 Ah) on terminals +ALI and GND 55mA on stand-by (without absorption on wired connections); 125mA with display lit; 500mA in alarm status. 12 Vdc ±30%; 1.2 A maximum total. 6 lines for NC contacts, programmable on the 3 zones A-B-C 3 lines for NC tamper contacts, programmable on the 3 zones A-B-C 1 line for connection of supplementary arming device 1 output for 12 V siren control, maximum 0.5 A; 1 output for self-powered siren 14 V 2 relay outputs (NC/C/NO contacts maximum 50 V-0.5 A) for programmable functions 2,250 Kg
Technical and additional specifications for models HSCU1G and HSCU1GC
GSM module, Quad-band, EGSM 850/900/1800/1900 MHz Output power: - Class 4 (2W) at 850 / 900 MHz - Class 1 (1W) at 1800 / 1900 MHz Sensitivity: - 107 dBm at 850 / 900 MHz - 106 dBm at 1800 / 1900 MHz Delivery of technical or alarm SMS messages. Caller ID recognition (for direct access). Hands-free communication
Technical specifications common to all models (HSCU1G, HSCU1, HSUC1GC, HSCU1C)
Up to 99 programmable detectors: immediate, delayed or AND, on 3 activation zones A-B-C or in 24-hour zones Panic, Robbery, Technical Alarm. Reception of tamper signal from each detector; reception of supervision and low battery signals. Digital transmission encoded at 72 bit, for alarm device control. Continuous, simultaneous and programmable control of 2 working frequencies. Last 200 events Programmable delayed activation; programmable input delay on each detector; general alarm time 3 minutes (fixed). Display 2 x 16 characters, with option of naming each peripheral (label). Built-in alphanumerical keypad, 20 keys. Alarm siren 106 db + buzzer with low intensity signal function. Vocal messages recordable on 32 Mbit flash memory for approx. 500 s of messages. Digitalised PCM user guide at 64 Kbps. Main communication guidelines for the user. Vocal synthesis with 125 pre-recorded “phrases”, available in the main languages. Digital bidirectional communication, in dual band frequency (433 and 868 Mhz) with quartz control; devices pre-encoded in the factory and managed in self-learning mode. 100m in open field free of disturbance or approx. 20 m inside buildings. Connection with standard RJ14 socket. Automatic adaptation to line characteristics in country of use, according to the selected language. Compatible with broadband lines. 307 x 200 x 53 mm from -10°C to +40°C
Technical specifications for models HSCU1GC and HSCU1
Battery Pack HSPS1 (9 V ~12 Ah) Class III (safety extra low voltage) Approx. 200 µA on stand-by; maximum 200 mA in alarm status with PSTN operative; maximum 400 mA in alarm status with GSM operative At least 2 years; autonomy estimated with 2 on/off cycles per day, 10 detectors present and 10 alarms per year. Autono­my is reduced in the event of numerous telephone calls 1,500 Kg
36
EC DECLARATION OF CONFORMITY
Note - The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S.p.a. and in particular to the last revision available before printing this manual. This declaration has been re-edited for editorial purposes.
Number: 305/HSC... Revision:0
The undersigned, Luigi Paro, in the role of Managing Director, declares under his sole responsibility, that the products
Manufacturer’s name: NICE s.p.a. Address: Via Pezza Alta 13, Z.I. Rustignè, 31046 - Oderzo (TV) Italy Type: Control units for alarm systems with 230V mains power supply or battery powered; with or without
GSM module
Model: HSCU1GC, HSCU1C, HSCU1G, HSCU1
Conform to the essential requirements stated in article 3 of the following EC directive, for the intended use of products:
• 1999/5/EC; DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 9 March 1999 regarding radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity according to the fol­lowing harmonised standards:
- Health protection: EN 50371:2002; EN50360:2001+A1:2006
- electrical safety: EN 60950-1:2006
- Electromagnetic compatibility: EN 301 489-1V1.8.1:2008; EN 301 489-17 V1.2.1:2002; EN301489-7 V1.3.1:2005
- Radio range: EN 300328 V1.7.1:2006; EN300440-2 V1.1.2:2004; EN 301511 V9.0.2:2003
In accordance with the directive 1999/5/EC (appendix V), the product is class 1 and marked:
The product also conforms with the requirements of the following EC directives:
• 2004/108/EEC (ex directive 89/336/EEC); DIRECTIVE 2004/108/EEC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 15 December 2004 regarding the approximation of member state legislation related to electromagnetic compatibility, repealing directive 89/336/EEC, according to the following harmonised standards: EN 50130-4:1995+A1:1995+A2:1995
Oderzo, 11.03.09
Luigi Paro
(Managing director)
0682
IST288ENR02.4862 – Rev.00 – 01-02-2010
Nice South Africa
Johannesburg South Africa info@co.za.niceforyou.com
Nice Polska
Pruszków Polska Ph. +48.(022).759.40.00 Fax +48.(022).759.40.22 info@pl.niceforyou.com
Nice Portugal
Mem Martins Portugal Ph. +351.21.922.82.10 Fax +351.21.922.82.19 info@pt.niceforyou.com
Nice Romania
Cluj Napoca Romania Ph./Fax +40.(0)264.453.127 info@ro.niceforyou.com
Nice Turkey
Kadikoy Istanbul Turkey Ph. +90.216.456.34.97 Fax +90.216.455.78.29 info@tr.niceforyou.com
Nice UK
Sutton in Ashfield United Kingdom Ph. +44.16.23.55.80.86 Fax +44.16.23.55.05.49 info@uk.niceforyou.com
www.niceforyou.com
Headquarters
Nice SpA
Oderzo TV Italia Ph. +39.0422.85.38.38 Fax +39.0422.85.35.85 info@niceforyou.com
Nice in Italy
Nice Padova
Padova Italia Ph. +39.049.87.01.05.1 Fax +39.049.87.07.63.8 infopd@niceforyou.com
Nice Roma
Roma Italia Ph. +39.06.72.67.17.61 Fax +39.06.72.67.55.20 inforoma@niceforyou.com
Nice Worldwide
Nice France
Buchelay France Ph. +33.(0)1.30.33.95.95 Fax +33.(0)1.30.33.95.96 info@fr.niceforyou.com
Nice France Sud
Aubagne France Ph. +33.(0)4.42.62.42.52 Fax. +33.(0)4.42.62.42.50 infomarseille@fr.niceforyou.com
Nice France Rhône Alpes
Decines Charpieu France Ph. +33.(0)4.78.26.56.53 Fax +33.(0)4.78.26.57.53 infolyon@fr.niceforyou.com
Nice Belgium
Leuven (Heverlee) Belgium Ph. +32.(0)16.38.69.00 Fax +32.(0)16.38.69.01 info@be.niceforyou.com
Nice Deutschland
Gelnhausen Deutschland Ph. +49.(0)6051.91.520 Fax +49.(0)6051.91.52.119 info@de.niceforyou.com
Nice España Madrid
Mostoles Madrid España Ph. +34.(0)9.16.16.33.00 Fax +34.(0)9.16.16.30.10 info@es.niceforyou.com
Nice España Barcelona
Sant Quirze del Valles Barcelona España Ph. +34.(0)9.37.84.77.75 Fax +34.(0)9.37.84.77.72 info@es.niceforyou.com
Nice Australia
Wetherill Park Australia Ph. +61.(0)2.96.04.25.70 Fax +61.(0)2.96.04.25.73 info@au.niceforyou.com
Nice China
Shanghai P. R. China Ph. +86.21.575.701.46 Fax +86.21.575.701.44 info@niceforyou.com.cn
Nice USA
San Antonio Texas USA info@us.niceforyou.com
Nice Russia
Odintsovo Moscow Region Russia Ph. +7.495.739.97.02 Fax +7.495.739.97.02 info@ru.niceforyou.com
Loading...